Sponsored Content
Operating Systems Linux How to Find out if an HP/Linux uses SAN or not? Post 302760661 by mrn6430 on Thursday 24th of January 2013 11:26:55 AM
Old 01-24-2013
How to Find out if an HP/Linux uses SAN or not?

Is there a command I can run on my HP /LINUX to see if uses SAN? This command work son AIX ls -al /DEV/rdsk however it does not work on HP Linux. Please let me know?

Thanks
 

10 More Discussions You Might Find Interesting

1. Solaris

Thoughts/experiences of SAN attaching V880 to EMC SAN

Hi everyone, I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN? At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies

2. Filesystems, Disks and Memory

Multiple Paths to SAN with LVM in Linux?

I'm setting up a CentOS 5 server that will be connected to an HP EVA4000. My previous experience is with an HP VA7400 and HP-UX. In HP-UX I can add "alternate paths" to a volume group in order to have redundant paths to the SAN via dual fiber channel HBAs just by either adding them with... (3 Replies)
Discussion started by: deckard
3 Replies

3. Linux

Linux on SAN

Hello everyone. I was wondering if there is a way to increase the size on the LUN on a SAN and make the Linux kernel understand the changes without restarting? In the past it has always been rebooted to see the new values but im sure that there is a way now for the lvm to see the Free PE in... (8 Replies)
Discussion started by: d_ark
8 Replies

4. Filesystems, Disks and Memory

Finding SAN Lun's on Linux.

Am trying to differentiate between the local disks and LUN's presented from SAN onto the server. Have Tried fdisk -l, however I quite cudn't differentiate the local disks from SAN presented LUN's. Can you pls. let me know the procedure and commands to find this. OS - RHEL 4 SAN - EMC... (3 Replies)
Discussion started by: Crazy_murli
3 Replies

5. Filesystems, Disks and Memory

how to create same paritations from same SAN disk on two linux servers

Hi All, Storage team assigned same SAN disk on two servers how to create same paritations from same SAN disk on two linux servers may i know options & procedure. But here one server writing on SAN disk and another server reading other files from SAN disks Thanks in advance (1 Reply)
Discussion started by: kurva
1 Replies

6. AIX

can't find a LTO3 drive through SAN,pls help!

Hi,everyone the situation is: at the very beginning ,through cfgmgr i find all LTO3 drives and 9840D drives. Then, some guy changed the device id(loop id) of all the stk drives on the tape lib panel. This time, i ran the cfgmgr but got nothing. so i asked that guy to change the loop id... (2 Replies)
Discussion started by: zzisking
2 Replies

7. AIX

How to find the status of SAN Disc through command prompt

How to find the status of SAN Disc through command prompt (1 Reply)
Discussion started by: AIXlearner
1 Replies

8. AIX

Find information for Host and SAN disconnect

Can someone point me in the right direction as to where I can find information on how to cleanly disconnect my AIX 5.3 host from our DS/4200 SAN. I have to do a firmware upgrade on the SAN. -Thanks (2 Replies)
Discussion started by: tfort73
2 Replies

9. Solaris

Find Brocade SAN switch’s IP in Sun server?

We have a Sun M5000 connecting to a Brocade SAN switch. I don't know the IP of the Brocade switch and don't want to use its serial port to get the info. How can I find the IP of the Brocade switch under Solaris 10? Snoop is not supported by Solaris multipathing. What other tools can I use to find... (6 Replies)
Discussion started by: aixlover
6 Replies

10. Red Hat

How to find the SAN path?

Hi folks, How to identify the SAN is running in Single path or dual source path for linux servers. (2 Replies)
Discussion started by: gsiva
2 Replies
st_san_safe(5)							     OBSOLETED							    st_san_safe(5)

NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED) VALUES
Failsafe Default Allowed values Recommended values or DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters st_san_safe(5)
All times are GMT -4. The time now is 05:27 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.