Hi to all
now we running mksysb to nim on aix servers.
we are planning to take mksysb from vio servers.
can we use the same script for vio servers.
thanks (10 Replies)
Hi,
I want to know wheather partition size for installation of vio client can be specified on vio server
example
If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Hello all,
I have been trying to run commands that collect basic info from the VIO's
The issue I am having is setting the env with the "oem_setup_env" after I login as "padmin".
I usually do the following:
ssh server command
ssh root@server date , but I need to login set the env and... (0 Replies)
hi,
I am using the below line to run a script from remote server(say server A) to another server(say server B).
ssh username@servername ksh script name.
The issue is the script logs into server B, executes the script on server B, transfers the file to server A but does not exit from... (4 Replies)
Hi
My vio client is getting its virtual Ethernet services from dual vio servers. What command if I execute on the vio
client will get me the names of the vio servers ? (2 Replies)
trying to put VIO server software into this p520, firmware upgraded to the latest and greatest..SF240_415_318 , I think
a few questions, on this practice AIX machine on AIX 7.1
VIO can only be installed if ASMI or HMC is running ???
if so, perhaps ASMI is much simpler, since I will need to... (2 Replies)
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Hi,
I would like to know installing vio server on local disk and mirroring rootvg,
if I am creating AIX VIO CLIENT(lpar),
and any of single local hard disk failuare.
will it affect lpars? will lpars able to boot.
what needs to be done? (1 Reply)
Hi,
I am facing an issue in vio server. When I run
bosboot -ad /dev/hdisk0
I am getting an error
trustchk: Verification of attributes failed: /usr/sbin/bootinfo
: accessauths
regards,
vjm
Please use code tags next time for your code and data. (8 Replies)
Hi,
I would like to know after the installation of vio server. how many logical network interfaces will be created on vio server if I am having two physical interfaces on vio server.
I am asking this question because I would like know to on the basis of logical network interfaces creation on... (0 Replies)
Discussion started by: manoj.solaris
0 Replies
LEARN ABOUT OSF1
vgreduce
VGREDUCE(8) System Manager's Manual VGREDUCE(8)NAME
vgreduce - reduce a volume group
SYNOPSIS
vgreduce [-a|--all] [-A|--autobackup y|n] [-d|--debug] [-h|-?|--help] [--removemissing] [-t|--test] [-v|--verbose] VolumeGroupName [Physi-
calVolumePath...]
DESCRIPTION
vgreduce allows you to remove one or more unused physical volumes from a volume group.
OPTIONS
See lvm for common options.
-a, --all
Removes all empty physical volumes if none are given on command line.
--removemissing
Removes all missing physical volumes from the volume group, if there are no logical volumes allocated on those. This resumes normal
operation of the volume group (new logical volumes may again be created, changed and so on).
If this is not possible (there are logical volumes referencing the missing physical volumes) and you cannot or do not want to remove
them manually, you can run this option with --force to have vgreduce remove any partial LVs.
Any logical volumes and dependent snapshots that were partly on the missing disks get removed completely. This includes those parts
that lie on disks that are still present.
If your logical volumes spanned several disks including the ones that are lost, you might want to try to salvage data first by acti-
vating your logical volumes with --partial as described in lvm (8).
SEE ALSO lvm(8), vgextend(8)Sistina Software UK LVM TOOLS 2.02.95(2) (2012-03-06) VGREDUCE(8)