12-03-2012
To Jps460,
I have never seen any luns not under VGs except raw devices for Oracle DB.
I am just wondering what purpose the luns are not under VGs is.
If you show me the output of bdf, I might give you an idea.
Cheers,
10 More Discussions You Might Find Interesting
1. HP-UX
Hi, I'm going to be involved in a migration of SAN islands to one big SAN. I've not worked with SANs before and I'm not sure how to approach this. I suspect the disk devices on the HP servers are going to change, when the EVA's and servers are plugged into this new Cisco 9509 switch.
Any... (0 Replies)
Discussion started by: Hils
0 Replies
2. Solaris
Hi everyone,
I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN?
At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies
3. AIX
hi all
just installed the netsec.options.tcpwrapper from expansion pack, which used to be a rpm, for my aix 6.1 test box.
it is so unpredictable. i set up the hosts.deny as suggested for all and allow the sshd for specific ip addresses/hostnames.
the tcpdchk says the hosts allowed and... (0 Replies)
Discussion started by: wf201626
0 Replies
4. Solaris
I am going to do a SAN Array migration and need the sequence of steps required on the Solaris cluster before moving the old array luns to new array luns.
Here are the steps and I need info on the bold points:( I might even be wrong on the sequence of steps please correct me if I am wrong)
1.... (0 Replies)
Discussion started by: sunshinedeepu
0 Replies
5. AIX
Hi all,
We are migrating our SAN storage from HSV360 to 3PAR. The system runs aix 6.1 version with HACMP.
Please let me know what are requirements from OS side and how are the data copied to the new disks. (10 Replies)
Discussion started by: ElizabethPJ
10 Replies
6. HP-UX
Hi,
I am very new to HP-UX, and we're going to be doing a SAN migration.
We're going to take down the machine, and zone it to the new SAN.
My question is, will the device names change and will that interfere with the LVM?
If the new disks come in with different device names, how would I... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies
7. Red Hat
I have an IBM blade running RHEL 5.4 server, connected to two Hitachi SANs using common fibre cards & Brocade switches. It has two volume groups made from old SAN LUNs. The old SAN needs to be retired so we allocated LUNs from the new SAN, discovered the LUNs as multipath disks (4 paths) and grew... (4 Replies)
Discussion started by: rbatte1
4 Replies
8. AIX
I'm New to AIX / VIOS
We're doing a FC switch cutover on an ibm device, connected via SAN.
How do I tell if one path to my remote disk is lost? (aix lvm)
How do I tell when my link is down on my HBA port?
Appreciate your help, very much! (4 Replies)
Discussion started by: BG_JrAdmin
4 Replies
9. Solaris
I am working on VM host and collecting data to identify the type of storage attached to the server which will be migrated to VNX.
it has one ldom created on it
luxadm probe output ---
No Network Array enclosures found in /dev/es
Found Fibre Channel device(s):
Node... (7 Replies)
Discussion started by: kpatel786
7 Replies
10. Solaris
Am trying to copy a tar file onto a series of remote hosts and untar it at the destination. Need to do this without having to do multiple ssh.
Actions to perform within a single ssh session via shell script
- copy a file
- untar at destination (remote host)
OS : Linux RHEL6 (3 Replies)
Discussion started by: sankasu
3 Replies
LEARN ABOUT HPUX
ifc_disable_mgmt_lun
ifc_disable_mgmt_lun(5) File Formats Manual ifc_disable_mgmt_lun(5)
NAME
ifc_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices
VALUES
Failsafe
Default
Allowed values
Enable discovery of management luns for array devices.
Disable discovery of management luns for array devices.
Recommended values
DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and
the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension
bus node. The entry for a legacy management lun looks like this:
On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual
extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns
requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of
management luns will free up virtual extension buses for use by data luns.
Who Is Expected to Change This Tunable?
System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device
special files.
Restrictions on Changing
Changes to this tunable take effect immediately. However, existing management luns will not be removed.
When Should the Tunable Be Turned On?
This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns.
What Are the Side Effects of Turning the Tunable Off?
None.
When Should the Tunable Be Turned Off?
When the functionality provided by the management luns is desired.
What Are the Side Effects of Turning the Tunable On?
Existing management luns in the legacy representation will show up in the state.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by HP.
SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M).
Tunable Kernel Parameters ifc_disable_mgmt_lun(5)