Sponsored Content
Full Discussion: List LPAR from VIOS
Operating Systems AIX List LPAR from VIOS Post 302732823 by rbatte1 on Monday 19th of November 2012 08:34:32 AM
Old 11-19-2012
What layout do you have?

If your partitioned with an HMC it will give you a nice view straight away.

If you used IVM of VIO (i.e. a single VIO is running natively on the server and you have VIO guests) then there should be a https GUI you can get at. It is possible to do it through line commands too, but it's a bit ugly.




Robin
Liverpool/Blackburn
UK
 

10 More Discussions You Might Find Interesting

1. AIX

Problem mapping LUN disk from VIOS to the LPAR

Hello guys, It would be so nice of you if someone can provide me with these informations. 1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies

2. AIX

DUAL VIOS & Client LPAR hangs at 25b3

I have a DUAL VIO ( IBM Virtual I/O ) setup on p 570. Two Vio server ( VIOS ) and many LPAR clients. VIO ( latest version + service pack + applied the fix ) and AIX 6.1 ML2 When both VIOs are running, and if I turn on a Client LPAR, the LPAR hangs at LED 25b3 for more than 1 hour then it... (2 Replies)
Discussion started by: filosophizer
2 Replies

3. AIX

VIOS to lpar Mapping

Hello, I have created mapping of 2 virtual adapters for Lpars using following command: mkvdev -vdev ipanalyzerlv1 -vadapter vhost11 mkvdev -vdev ipanalyzerlv -vadapter vhost13 The above two commands were succesfull but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Discussion started by: Vit0_Corleone
3 Replies

4. AIX

LPAR freezes after switching of storage (lpar is mirrored)

Hi all, I have the following configuration 2 ds3524 storage disk systems located over 2 locations 2 P720 server located over 2 locations DS3524 are connected to san switch. Each vio server has 1 fc adapter attached to a san switch. per p720 server 2 virtual io servers. Vio 1 has 1 lun... (2 Replies)
Discussion started by: markiemark
2 Replies

5. AIX

What's the difference between VIOS and LPAR?

Hi All, Besides the licenses on VIO and LPAR. What's the main difference with the two? I have installed VIO, my manager told me so, because it's like a free hypervisor but I never installed LPAR before. How do you install it? And if you can give more info on the two, that would be great. ... (5 Replies)
Discussion started by: itik
5 Replies

6. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies

7. AIX

VIOS LPAR Error 0518

I am trying to install AIX 5.3 on one of the LPARs through VIOS but I get this error 0518 Reference Code Selection 0518 (Time stamp: 12/18/12 12:10:20 AM UTC) Starting kernel (Time stamp: 12/18/12 12:10:15 AM UTC) AIX is starting. (Time stamp: 12/18/12 12:10:15 AM... (10 Replies)
Discussion started by: filosophizer
10 Replies

8. AIX

Moving VIOS, LPAR's, HMC to different subnet

Hi, Just joined to new company with one Power 720 Express (8202-E4C) server and have no much experience with IBM systems. I am trying to move everything I mentioned to different subnet as required by customer contract (currently sitting on same subnet as company lan). Access to this subnet will... (8 Replies)
Discussion started by: spricer
8 Replies

9. AIX

VIOS: Extend virtual disk assigned to running lpar?

Hello, VIOS 2.2.1.4 using IVM. I'm trying to extend a virtual disk assigned to a running lpar so that I can expand the lpar's datavg and grow some filesystems for the user. Storage admin expanded the lun and new size was reflected in VIO right away. I then needed the storage pool to... (2 Replies)
Discussion started by: j_aix
2 Replies

10. UNIX for Advanced & Expert Users

Unable to install client AIX LPAR to vscsi hdisk provided from VIOS

Hi everybody, I have Power5 server with 4 internal hdisks each of 70Gb. VIOS server was installed via Virtual I/O Server Image Repository on the HMC. HMC release - 7.7.0 VIOS rootvg installed on 2 disk(these disks merged to one storage pool during VIOS install process),and 2 others hdisks... (2 Replies)
Discussion started by: Ravil Khalilov
2 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_lpar - Fence agent for IBM LPAR DESCRIPTION
fence_lpar accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_lpar can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -x, --ssh SSH connection (Default Value: 1) -k, --identity-file=<filename> Identity file for ssh -n <id> Name of the partition Partition name -s <id> Name of the managed system Managed system name -H, --hmc-version=<version> Force HMC version to use (3 or 4) (Default Value: 4) -c, --command-prompt=<prompt> Force command prompt (Default Value: [':~>', ']$', '$ ']) -4, --inet4-only Forces agent to use IPv4 addresses only -6, --inet6-only Forces agent to use IPv6 addresses only -u, --ipport=<port> TCP port to use for connection with device -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit -C, --separator=<char> Separator for CSV created by operation list (Default Value: ,) --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 15) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 0) --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password secure SSH connection (Default Value: 1) identity_file Identity file for ssh partition Partition name managed Managed system name hmc_version Force HMC version to use (3 or 4) (Default Value: 4) cmd_prompt Force command prompt (Default Value: [':~>', ']$', '$ ']) inet4_only Forces agent to use IPv4 addresses only inet6_only Forces agent to use IPv6 addresses only ipport TCP port to use for connection with device verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit separator Separator for CSV created by operation list (Default Value: ,) power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 15) power_wait Wait X seconds after issuing ON/OFF (Default Value: 0) delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_lpar (Fence Agent) 2009-10-20 FENCE_AGENT(8)
All times are GMT -4. The time now is 02:49 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy