Sponsored Content
Full Discussion: [Solved] D380/2 hard drive
Operating Systems HP-UX [Solved] D380/2 hard drive Post 302731581 by HP-UX Hardware on Thursday 15th of November 2012 11:17:39 AM
Old 11-15-2012
The D3xx server takes the 7200 hot swap type disk drives. HP didnt make anything bigger than a 18GB for those boxes but its possible to get 36GB and 180GB drive to work in there. I listed some reference numbers for them

ST18331X - 18GB
A5528A - 18GB
ST36331X - 36GB
ST180331X - 180GB

11i v1 is the best you can do on the D boxes.
This User Gave Thanks to HP-UX Hardware For This Post:
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

I Want To Automount My Hard Drive!!!

:confused: Im as newbie as they come....... I just loaded Red Hat 8.0 on my computer. I have a second hard drive that i reformatted with a Fat32 so I could share it with my XP and Linux partions....... I have like 4000 mp3's on it and i would like to get it to auto mount when Linux boots....? Or... (5 Replies)
Discussion started by: mynameiskyle
5 Replies

2. UNIX for Dummies Questions & Answers

Partition Hard drive

Hello everyone. I am new to Linux so hope some one could help me here. I have a 30 Gb HD and windows Xp is my O/S, HD is not partitioned,but I want to Partitioned it, so I could Install Knoppix(Linux)on one of the partitioned one, how could I do this? OR should I erase every thing and then... (1 Reply)
Discussion started by: amir
1 Replies

3. UNIX for Dummies Questions & Answers

Trying to copy old hard drive to new hard drive.

:confused: ........I have a new hard drive and I need to copy ALL info from the old to the new. I would like to use the dd command. I know the command is as follows...... dd if=/dev/rdsk/c1t1d0s0 of=/dev/rdsk/???????? Where I have the question marks is the problem. How do I find out what the... (4 Replies)
Discussion started by: shorty
4 Replies

4. Filesystems, Disks and Memory

The best partitioning schem for a 250GB Sata hard drive & a 75GB SCSI hard drive

Hi I have 2 75GB SCSI hard drives and 2 250GB SATA hard drives which are using RAID Level 1 respectively. I wana have both FTP and Apache installed on them as services. I'm wondering what's the best partitioning schem? I wana use FC3 as my OS, so, I thought I can use the 75GB hard drive as the /... (0 Replies)
Discussion started by: sirbijan
0 Replies

5. Solaris

wiping hard drive

I'm looking for a utility that will wipe data clean from a Solaris hard drive and make the data unreadable and unrecoverable. Any suggestions? Does SUN have something? (3 Replies)
Discussion started by: dangral
3 Replies

6. Filesystems, Disks and Memory

Hard Drive Temperature?

Hi, I just set up a raid Z array in solaris xpress and I notice that the drives feel pretty damn hot. I use speedfan to monitor the temperatures of the hard drives in XP. Is there a similar program for solrais? I assume there would be since the drives all have temp sensors in them, but I... (2 Replies)
Discussion started by: ciscocbee
2 Replies

7. SCO

I need a help with accessing the hard drive

Hello guys, I have got from a friend a hard disk which was used in the SCO OpenServer. He needs some data from it. I have no clue how to copy its content with Linux or Windows-I have tried few Linux distros but the result is always the same-the file system is not recognized so can't be mounted.... (4 Replies)
Discussion started by: kataro
4 Replies

8. Hardware

[solved] Sun Netra X1 - Adding a Second Hard Drive

As the title suggests, I'm trying to install a second drive (really want an OS mirror) on a Sun Netra X1. I've taken the spacer out, and had a go at with the drill-press so now I have a nice HDD tray. Have installed an IDE drive in the tray, plugged in the power and data cables that were... (0 Replies)
Discussion started by: Smiling Dragon
0 Replies

9. UNIX for Advanced & Expert Users

External hard drive

I have connected an external hard drive. I can't find it. Both ls /media, fdisk -l and ls /dev show nothing. TIA (3 Replies)
Discussion started by: Meow613
3 Replies
HPSA(4) 						     Linux Programmer's Manual							   HPSA(4)

NAME
hpsa - HP Smart Array SCSI driver SYNOPSIS
modprobe hpsa [ hpsa_allow_any=1 ] DESCRIPTION
hpsa is a SCSI driver for HP Smart Array RAID controllers. Options hpsa_allow_any=1: This option allows the driver to attempt to operate on any HP Smart Array hardware RAID controller, even if it is not explicitly known to the driver. This allows newer hardware to work with older drivers. Typically this is used to allow installation of operating systems from media that predates the RAID controller, though it may also be used to enable hpsa to drive older controllers that would normally be handled by the cciss(4) driver. These older boards have not been tested and are not supported with hpsa, and cciss(4) should still be used for these. Supported hardware The hpsa driver supports the following Smart Array boards: Smart Array P700M Smart Array P212 Smart Array P410 Smart Array P410i Smart Array P411 Smart Array P812 Smart Array P712m Smart Array P711m StorageWorks P1210m Since Linux 4.14, the following Smart Array boards are also supported: Smart Array 5300 Smart Array 5312 Smart Array 532 Smart Array 5i Smart Array 6400 Smart Array 6400 EM Smart Array 641 Smart Array 642 Smart Array 6i Smart Array E200 Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E200i Smart Array E500 Smart Array P400 Smart Array P400i Smart Array P600 Smart Array P700m Smart Array P800 Configuration details To configure HP Smart Array controllers, use the HP Array Configuration Utility (either hpacuxe(8) or hpacucli(8)) or the Offline ROM-based Configuration Utility (ORCA) run from the Smart Array's option ROM at boot time. FILES
Device nodes Logical drives are accessed via the SCSI disk driver (sd(4)), tape drives via the SCSI tape driver (st(4)), and the RAID controller via the SCSI generic driver (sg(4)), with device nodes named /dev/sd*, /dev/st*, and /dev/sg*, respectively. HPSA-specific host attribute files in /sys /sys/class/scsi_host/host*/rescan This is a write-only attribute. Writing to this attribute will cause the driver to scan for new, changed, or removed devices (e.g., hot-plugged tape drives, or newly configured or deleted logical drives, etc.) and notify the SCSI midlayer of any changes detected. Normally a rescan is triggered automatically by HP's Array Configuration Utility (either the GUI or the command-line variety); thus, for logical drive changes, the user should not normally have to use this attribute. This attribute may be useful when hot plugging devices like tape drives, or entire storage boxes containing preconfigured logical drives. /sys/class/scsi_host/host*/firmware_revision This attribute contains the firmware version of the Smart Array. For example: # cd /sys/class/scsi_host/host4 # cat firmware_revision 7.14 HPSA-specific disk attribute files in /sys /sys/class/scsi_disk/c:b:t:l/device/unique_id This attribute contains a 32 hex-digit unique ID for each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat unique_id 600508B1001044395355323037570F77 /sys/class/scsi_disk/c:b:t:l/device/raid_level This attribute contains the RAID level of each logical drive. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat raid_level RAID 0 /sys/class/scsi_disk/c:b:t:l/device/lunid This attribute contains the 16 hex-digit (8 byte) LUN ID by which a logical drive or physical device can be addressed. c:b:t:l are the controller, bus, target, and lun of the device. For example: # cd /sys/class/scsi_disk/4:0:0:0/device # cat lunid 0x0000004000000000 Supported ioctl() operations For compatibility with applications written for the cciss(4) driver, many, but not all of the ioctls supported by the cciss(4) driver are also supported by the hpsa driver. The data structures used by these ioctls are described in the Linux kernel source file include/linux/cciss_ioctl.h. CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD These three ioctls all do exactly the same thing, which is to cause the driver to rescan for new devices. This does exactly the same thing as writing to the hpsa-specific host "rescan" attribute. CCISS_GETPCIINFO Returns PCI domain, bus, device and function and "board ID" (PCI subsystem ID). CCISS_GETDRIVVER Returns driver version in three bytes encoded as: (major_version << 16) | (minor_version << 8) | (subminor_version) CCISS_PASSTHRU, CCISS_BIG_PASSTHRU Allows "BMIC" and "CISS" commands to be passed through to the Smart Array. These are used extensively by the HP Array Configuration Utility, SNMP storage agents, and so on. See cciss_vol_status at <http://cciss.sf.net> for some examples. SEE ALSO
cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8), <http://cciss.sf.net>, and Documentation/scsi/hpsa.txt and Documentation/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source tree COLOPHON
This page is part of release 4.15 of the Linux man-pages project. A description of the project, information about reporting bugs, and the latest version of this page, can be found at https://www.kernel.org/doc/man-pages/. Linux 2017-09-15 HPSA(4)
All times are GMT -4. The time now is 01:15 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy