11-14-2012
your volume group is not concurrent capable, not required, but suggested.
are your disks present on all cluster nodes for this resource group?
10 More Discussions You Might Find Interesting
1. AIX
Hello
I am a noobie to HACMP
I have 2 55A servers and a 7031 disk subsystem
For HACMP to work, do I need to have the hdisks on both servers to match the same drives??
The hdisks on each box are currently different:
hdisk0 and hdisk1 are the internal disks and hdisk2-5 are on the D24 on... (1 Reply)
Discussion started by: mhenryj
1 Replies
2. Solaris
I would like to extend a logical drive on our 3510. I have four unallocated disks which I would like to use for this purpose.
The 3510 supports a Sun Cluster but for now all I wish to see is a "new" disk when I run format.
I am a little familiar with the telnet/ssh session on the 3510 but am... (2 Replies)
Discussion started by: malcqv
2 Replies
3. AIX
Hello,
This morning we have added 6 new disks (73 Gb) to our DS4300, then created a new Array en then created a logical drive, after this was done, teh following error occourd on the last 3 (new)disks:
Date/Time: 22-4-08 6:56:26
Sequence number: 5472
Event type: 282D
Event category:... (1 Reply)
Discussion started by: topper
1 Replies
4. HP-UX
Hi,
Can anybody advice whether it is possible to configure HACMP in HP-UX Server.
To my knowledge HACMP is IBM Solution.
Thanks && Regards,
N. Poorna Chandra Rao. (2 Replies)
Discussion started by: npcrao
2 Replies
5. AIX
Hi all,
I have an HACMP (v5.3.0.0) cluster vg attached to ibm shark that need to be decommissioned. The data need to move to the HP EVA disk. The OS is on AIX 5200-10. The plan is to add a new disk from EVA & mirror the existing vg & break the mirror from Shark disk once the mirror finished.
... (12 Replies)
Discussion started by: CW15
12 Replies
6. Shell Programming and Scripting
I need some help with adding lines to file and substitute a pattern.
Ok I have a file:
#cat names.txt
name: John Doe
stationed: 1
name: Michael Sweets
stationed: 41
.
.
.
And would like to change it to:
name: John Doe
employed
permanently
stationed: 1-office (7 Replies)
Discussion started by: hemo21
7 Replies
7. AIX
hi,
when I do a failover, hacmp always starts db2 but recently it fails to start db2..noticed the issue is db2nodes.cfg is not modified by hacmp and is still showing primary node..manually changed the node name to secondary after which db2 started immediately..unable to figure out why hacmp is... (4 Replies)
Discussion started by: gkr747
4 Replies
8. AIX
Hi,
I have a 2 node Cluster. Which is working in active/passive mode (i.e Node#1 is running and when it goes down the Node#2 takes over)
Now there's this requirement that we need a mount point say /test that should be available in active node #1 and when node #1 goes down and node#2 takes... (6 Replies)
Discussion started by: aixromeo
6 Replies
9. AIX
Previous forum threads have noted that AIX cannot use iSCSI disks because it fails when trying to add them to a volume group using mkvg. The failure is caused by AIX's use of the SCSI "WRITE AND VERIFY"(0x2e) command which some iSCSI targets do not support.
We experienced the same problem using... (1 Reply)
Discussion started by: garethr
1 Replies
10. UNIX for Beginners Questions & Answers
I have an array in an external file, "array.txt", which contains:
char *testarray={"Zero", "One", "Two", "Three", "Four", "Five", "Six", "Seven", "Eight", "Nine"};I want to be able to add an element to this array, and have that element display, whenever I call it, without having to recompile... (29 Replies)
Discussion started by: ignatius
29 Replies
LEARN ABOUT HPUX
fcd_disable_mgmt_lun
fcd_disable_mgmt_lun(5) File Formats Manual fcd_disable_mgmt_lun(5)
NAME
fcd_disable_mgmt_lun - select whether or not management luns are discovered in the legacy representation of mass storage devices
VALUES
Failsafe
Default
Allowed values
Enable discovery of management luns for array devices.
Disable discovery of management luns for array devices.
Recommended values
DESCRIPTION
Management luns provide the means to access the control ports of Fibre Channel disk arrays. They are represented in both the legacy and
the agile view of storage devices. The legacy representation of a management lun is typically created under a separate virtual extension
bus node. The entry for a legacy management lun looks like this:
On a system with a large number of storage devices connected, creation of management luns can result in an insufficient number of virtual
extension buses for the legacy representation of data luns. Since the number of extension buses on a system is limited to 256, luns
requiring virtual extension buses above 256 will be unusable through legacy device special files. Disabling the discovery and creation of
management luns will free up virtual extension buses for use by data luns.
The default value for this tunable is
Who Is Expected to Change This Tunable?
System administrators who expect to use a large number of storage devices requiring more than 256 extension buses through legacy device
special files.
Restrictions on Changing
Changes to this tunable take effect immediately. However, existing management luns will not be removed.
When Should the Tunable Be Turned On?
This tunable should be turned on when the system runs out of extension buses for configuring the legacy representation of data luns.
What Are the Side Effects of Turning the Tunable Off?
None.
When Should the Tunable Be Turned Off?
When the functionality provided by the management lun is desired.
What Are the Side Effects of Turning the Tunable On?
Existing management luns in the legacy representation will show up in the state.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard Company.
SEE ALSO
ioinit(1M), ioscan(1M), kctune(1M).
Tunable Kernel Parameters fcd_disable_mgmt_lun(5)