Sponsored Content
Operating Systems AIX VIOS FC Mapping/NPIV questions Post 302728931 by juredd1 on Thursday 8th of November 2012 05:24:47 PM
Old 11-08-2012
I see the two cards from the SMS menu on the client side that were defined for the client in the HMC, but when looking at lsmap on the VIO side I still see no changes to the output for my vfchost. I have two physical FC cards in my VIO Server should it matter which one I picked when I ran the vfcmap command?
 

10 More Discussions You Might Find Interesting

1. AIX

Problem mapping LUN disk from VIOS to the LPAR

Hello guys, It would be so nice of you if someone can provide me with these informations. 1) My SAN group assigned 51G of LUN space to the VIO server.I ran cfgdev to discover the newly added LUN. Unfortunately most of the disks that are in VIO server is 51G. How would I know which is the newly... (3 Replies)
Discussion started by: solaix14
3 Replies

2. AIX

VIOS to lpar Mapping

Hello, I have created mapping of 2 virtual adapters for Lpars using following command: mkvdev -vdev ipanalyzerlv1 -vadapter vhost11 mkvdev -vdev ipanalyzerlv -vadapter vhost13 The above two commands were succesfull but when I want to map the third virtual device to the same Lpar than... (3 Replies)
Discussion started by: Vit0_Corleone
3 Replies

3. AIX

Anyone using NPIV?

Is anyone here using NPIV with AIX? If you are, what type of switch are you connected to? Also, please share some impressions of NPIV over traditional port-to-port LUN assignments. We are looking to move to NPIV and need some convincing argume... I mean information. (2 Replies)
Discussion started by: kah00na
2 Replies

4. AIX

Migrating hdisks from vscsi to NPIV with powerpath

Hi All, I'm preparing to migrate some servers from vscsi to pass-thru NPIV. I am planning to have the SAN team move the exact LUNs from vio1/vio2 to those two VWWN through NPIV. My question is on the partition itself.. right now, let's say I have hdisk0/1/2/3/4 that are part of datavg. They... (2 Replies)
Discussion started by: lapfrank
2 Replies

5. AIX

Vscsi and npiv on same adapter

Hi, I want to change from vscsi to npiv. Is it possible to use both on the same adapter, so we can change the systems one by one, or must we place a second FC adapter in the VIO servers? Thanks, Ronald (2 Replies)
Discussion started by: ronaldm60
2 Replies

6. AIX

Few VIOS questions

Hi, I would like to ask you if you could help me to answer these questions. Please. How to check in vios, size all pv's and to what they are mapped to? How to chech on vios/hmc which PowerVM edition is used? Thank you. (7 Replies)
Discussion started by: phobus
7 Replies

7. AIX

NPIV mapping problem

Hello all I hope someone can help me with this. I have a single LPAR which is supplied a rootvg and datavg disk set from a dual VIO server configuration. I see dual path disks for all the datavg disks but only see one path for the rootvg disks. The client LPAR has the following: fcs0 ... (3 Replies)
Discussion started by: johnf
3 Replies

8. Shell Programming and Scripting

Creating unique mapping from multiple mapping

Hello, I do not know if this is the right title to use. I have a large dictionary database which has the following structure: where a b c d e are in English and p q r s t are in a target language., the two separated by the delimiter =. What I am looking for is a perl script which will take... (5 Replies)
Discussion started by: gimley
5 Replies

9. AIX

NPIV custom WWN

Hi All :) i would like to know if i can customize the WWN of the new VFC (NPIV). Or, if i must move the LPAR on another server with another FCS, i have to change the zoning?? Thanks in advance. Mario ---------- Post updated 09-21-12 at 02:51 AM ---------- Previous update was 09-20-12 at... (1 Reply)
Discussion started by: Zio Bill
1 Replies

10. AIX

VIOS IP address - separate vlan for vios servers ?

Hello, Lets say for simplicity that I do not use any vlan config inside my server - one lpar group use hea physical port1, another group hea physical port2. Physical port1 configured as vlan1 on external switch, physical port2 as vlan2. What is the common practice - should I isolate my vios... (0 Replies)
Discussion started by: vilius
0 Replies
sndconfig(8)						      System Manager's Manual						      sndconfig(8)

NAME
sndconfig - configure sound card for use with Linux kernel modules SYNOPSIS
sndconfig {--help,--noprobe,--noautoconfig} DESCRIPTION
sndconfig sets up the necessary configuration files to use a sound card on a Red Hat system. If PnP support is compiled in, by default snd- config will do an initial probe for PnP sound cards using the pnpdump utility. If the --noprobe option is given this step will be skipped. The user will be notified if any cards were found. Otherwise the user must pick the card type from a menu. Then the user must choose the I/O port, IRQ, and DMA settings for the sound card. These must be known ahead of time and depend upon the jumper settings of the sound card. For PnP cards, the program will determine settings for the card; if the --noautoconfig option is given the user can choose the val- ues which will be programmed into the PnP device. There is no guarantee that the values entered do not conflict with an existing non-PnP or PnP device. The user must make sure these types of conflicts do not occur. OPTIONS --help Print a usage message on standard output and exit successfully. --noprobe No probe will be made for PnP cards, and the PnP configuration files will not be changed. --noautoconfig No autoconfiguration of PnP cards will be done; the user will be prompted for settings. FILES
/etc/sysconfig/soundcard Stores current settings /etc/modules.conf Stores sound module configuration /etc/isapnp.conf Stores PnP configuration SEE ALSO
isapnp(1), pnpdump(1) Wed Aug 19 1998 sndconfig(8)
All times are GMT -4. The time now is 04:15 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy