Sponsored Content
Full Discussion: Do You Own a Kindle?
The Lounge What is on Your Mind? Do You Own a Kindle? Post 302726359 by Luca.Francesca on Sunday 4th of November 2012 07:43:16 AM
Old 11-04-2012
Calibre isn't perfect and usually tecnical books are Pdf.
Epub is getting used more often (O'Reilly for one) and epub->awz3 is very good.
Equations, indeed, are always a problem.
But changing the Kindle from vertical view to the orizontal one, helps Smilie
 

We Also Found This Discussion For You

1. Hardware

Forcing Linux to keep charging my Kindle

Linux seems to have weird USB power saving features, my Kindle 3 only gets some charge before Linux powers down the USB port. When the device is mounted, it doesn't get enough power, with this same hardware under Windows I don't get the message on the Kindle "currently your kindle is not... (2 Replies)
Discussion started by: John Tate
2 Replies
VWRIGHT(1)						      General Commands Manual							VWRIGHT(1)

NAME
vwright - normalize a RADIANCE view, shift it to the right SYNOPSIS
vwright [ view options ] distance vwright [ view options ] name DESCRIPTION
In the first form, vwright shifts a RADIANCE view the specified distance to the right, putting out a complete set of view parameters in a single line on the standard output. This utility is most often used to compute a right-eyed view from a left-eye view for stereo imaging. If no options are specified on the command line, vwright reads a view from its standard input. The distance given is in world coordinate units. A negative value indicates a shift to the left rather than the right. The second form substitutes a name prefix in place of the shift distance, and produces constant assignments on the standard output suitable for passing directly to rcalc(1). For a given prefix N, the constant names are as follows: Nt: view type ('v'==1,'l'==2,'a'==3,'h'==4,'c'==5,'s'==6) Npx: view point x value Npy: view point y value Npz: view point z value Ndx: view direction x value (normalized) Ndy: view direction y value (normalized) Ndz: view direction z value (normalized) Nd: view focal distance Nux: view up vector x value (normalized) Nuy: view up vector y value (normalized) Nuz: view up vector z value (normalized) Nh: view horizontal size Nv: view vertical size Ns: view shift Nl: view lift No: view fore clipping distance Na: view aft clipping distance Nhx: derived horizontal image vector x value (normalized) Nhy: derived horizontal image vector y value (normalized) Nhz: derived horizontal image vector z value (normalized) Nhn: derived horizontal image vector multiplier Nvx: derived vertical image vector x value (normalized) Nvy: derived vertical image vector y value (normalized) Nvz: derived vertical image vector z value (normalized) Nvn: derived vertical image vector multiplier EXAMPLES
To start rpict(1) on a view .06 meters left of the view in the file "right.vf": rpict `vwright -.06 < right.vf` scene.oct > right.hdr & To move the rad(1) view named "left" 2.5 inches to the right and render from there: rad -v "right `rad -n -s -V -v left examp.rif | vwright 2.5`" examp.rif & To pass a view to rcalc for conversion to some other view: rcalc -n -e `vwright orig < orig.vf` -f viewmod.cal -o view.fmt > new.vf AUTHOR
Greg Ward SEE ALSO
pdfblur(1), rad(1), rcalc(1), rpict(1), rvu(1) RADIANCE
8/29/96 VWRIGHT(1)
All times are GMT -4. The time now is 01:44 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy