Hi,

You will have to set the disk as the hot spare for the disk group like;

Code:
vxedit -g "group_name" set spare=on "disk"

I can't remember if you have to add the disk to the group, but if you do you'll have to use the following;

Code:
vxdg -g "group" adddisk "disk"="device"

Regards

Dave
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Vfstab on spare disk - HOW ? Mount ?

Hi, guys ! Could someone clarify one thing for me: I start machine from disk0, and want to check the /etc/vfstab on disk1. How do i do it ? Tried to write: cd / mount /dev/dsk/c0t1d0s0 /mnt But if I do cd /mnt, it is empty. I expected to see disk1 there ? Or am I wrong ? How do I... (3 Replies)
Discussion started by: DGoubine
3 Replies

2. Filesystems, Disks and Memory

SCSI disk spare sectors

Is there a way to determine the number of available spare sectors on a disk ? as it may be useful for notifying a user to take a backup of the disk before it runs into a medium error. (6 Replies)
Discussion started by: rednex
6 Replies

3. SuSE

SLES11 - RAID6 all disks marked as Spare

Hello, After a replacement of the motherboard of my server, all disks belonging to a raid6 are now marked as spare. Is there any way to mark those disks as active and restore the raid6? $ cat /proc/mdstat Personalities : md1 : inactive sda1(S) sdk1(S) sdj1(S) sdi1(S) sdh1(S)... (0 Replies)
Discussion started by: xavix
0 Replies

4. UNIX for Dummies Questions & Answers

copy failing disk to Spare

Hi Guys, I have a failing 4gb (c0t5d0) drive that contains lvol4 -8 on hp-ux. It's not the boot disk but is part of VG00 volume group. Within that group, I have a disk (c0t4d0) of the same size that has 1 lvol on it for swap(4gb) I also have a seperate 1.5 gb swap volume on another physical disk... (1 Reply)
Discussion started by: rees_a
1 Replies

5. Solaris

Hot Spare pool

One more query in SVM :) Now with hot spare spool... I can understand adding/replacing a slice in particular hot spare pool with "-a / -r" option (or) adding a slice to all existing hot spare pool with "-all" option. Here my query is for deleting, we have only option "-d". 1) If the hot... (2 Replies)
Discussion started by: gowthamakanthan
2 Replies

6. Solaris

Hot Spare replacement

Hi Guys, Can Someone pls let me know the thorough process for Hot spare replacement as current Hot spare slice has broken down . :mad: Thanks ---------- Post updated at 06:34 PM ---------- Previous update was at 05:21 PM ---------- Update : Its a solaris 10 box (1 Reply)
Discussion started by: Solarister
1 Replies

7. Solaris

Can v240 disks be moved to v440 and have a chance of working?

We have a v240 running Solaris 10, and an application that I don't want to go through the pain of reinstalling on a new system right now. Can I just move those disks to a v440 for an easy upgrade? At first I thought the idea was laughable, but then I started thinking that they are both Ultra... (9 Replies)
Discussion started by: lyle
9 Replies

8. Programming

C- trying to code a 'spare array'; 'enum' fauled.

I am trying to implement a spare array in C that would be referenced by regular integers. Right away: define array for maximum possible index elements completely is not what I trying to get!!! It should be a construction that would have just 2 elements if I need to have just two indexes, like... (8 Replies)
Discussion started by: alex_5161
8 Replies

9. Solaris

Sun Fire 480 - devfsadm -C not working after replacing one of the boot disks

Our SunFire 480 - one of the boot disks failed. It is mirrored with VxVm. I followed the exact steps that is detailed in the veritas and sun guides (I can not post the URL since I don't have 5 posts yet.) After removing the failed disk, I ran devfsadm -C -c disk and it still shows the device... (7 Replies)
Discussion started by: jtamminen
7 Replies

10. Solaris

How to determine if i have spare disks in Solaris?

Hi Guys, obviously new to SOLARIS SUN SPARC 5.10 I would really appreciate if you help me see how to find free disks available in my system. Like i am a linux admin. If i want to grow a file system in linux. I would first have a look at my volume groups to see if they have free PEs if not then... (2 Replies)
Discussion started by: aiqbal
2 Replies
vxsparecheck(1M)														  vxsparecheck(1M)

NAME
vxsparecheck - monitor Veritas Volume Manager for failure events and replace failed disks SYNOPSIS
/etc/vx/bin/vxsparecheck [mail-address...] DESCRIPTION
The vxsparecheck command monitors Veritas Volume Manager (VxVM) by analyzing the output of the vxnotify command, waiting for failures to occur. It then sends mail via mailx to the logins specified on the command line, or (by default) to root. It then replaces any failed disks. After an attempt at replacement is complete, mail will be sent indicating the status of each disk replacement. The mail notification that is sent when a failure is detected follows this format: Failures have been detected by the Veritas Volume Manager: failed disks: medianame ... failed plexes: plexname ... failed subdisks: subdiskname ... failed volumes: volumename ... The Volume Manager will attempt to find hot-spare disks to replace any failed disks and attempt to reconstruct any data in volumes that have storage on the failed disk. The medianame list specifies disks that appear to have completely failed. The plexname list show plexes of mirrored volumes that have been detached due to I/O failures experienced while attempting to do I/O to subdisks they contain. The subdiskname list specifies subdisks in RAID-5 volumes that have been detached due to I/O errors. The volumename list shows non-RAID-5 volumes that have become unusable because disks in all of their plexes have failed (and are listed in the ``failed disks'' list) and shows those RAID-5 volumes that have become unusable because of multiple failures. If any volumes appear to have failed, the following paragraph will be included in the mail: The data in the failed volumes listed above is no longer available. It will need to be restored from backup. Replacement Procedure After mail has been sent, vxsparecheck finds a hot spare replacement for any disks that appear to have failed (that is, those listed in the medianame list). This involves finding an appropriate replacement for those eligible hot spares in the same disk group as the failed disk. A disk is eligible as a replacement if it is a valid Veritas Volume Manager disk (VM disk), has been marked as a hot-spare disk and con- tains enough space to hold the data contained in all the subdisks on the failed disk. To determine which disk from among the eligible hot spares to use, vxsparecheck first checks the file /etc/vx/sparelist (see Sparelist File below). If this file does not exist or lists no eligible hot spares for the failed disk, the disk that is ``closest'' to the failed disk is chosen. The value of ``closeness'' depends on the controller, target and disk number of the failed disk. A disk on the same controller as the failed disk is closer than a disk on a different controller; and a disk under the same target as the failed disk is closer than one under a different target. If no hot spare disk can be found, the following mail is sent: No hot spare could be found for disk medianame in diskgroup. No replacement has been made and the disk is still unusable. The mail then explains the disposition of volumes that had storage on the failed disk. The following message lists disks that had storage on the failed disk, but are still usable: The following volumes have storage on medianame: volumename These volumes are still usable, but the redundancy of those volumes is reduced. Any RAID-5 volumes with storage on the failed disk may become unusable in the face of further failures. If any non-RAID-5 volumes were made unusable due to the failure of the disk, the following message is included: The following volumes: volumename have data on medianame but have no other usable mirrors on other disks. These volumes are now unusable and the data on them is unavailable. If any RAID-5 volumes were made unavailable due to the disk failure, the following message is included The following RAID-5 volumes: volumename had storage on medianame and have experienced other failures. These RAID-5 volumes are now unusable and data on them is unavailable. If a hot-spare disk was found, a hot-spare replacement is attempted. This involves associating the device marked as a hot spare with the media record that was associated with the failed disk. If this is successful, the vxrecover(1M) command is used in the background to recover the contents of any data in volumes that had storage on the disk. If the hot-spare replacement fails, the following message is sent: Replacement of disk medianame in group diskgroup failed. The error is: error message If any volumes (RAID-5 or otherwise) are rendered unusable due to the failure, the following message is included: The following volumes: volumename occupy space on the failed disk and have no other available mirrors or have experienced other failures. These volumes are unusable, and the data they contain is unavailable. If the hot-spare replacement procedure completed successfully and recovery is under way, a final mail message is sent: Replacement of disk medianame in group diskgroup with disk device sparedevice has successfully completed and recovery is under way. If any non-RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following volumes: volumename occupy spare on the replaced disk, but have no other enabled mirrors on other disks from which to perform recovery. These volumes must have their data restored. If any RAID-5 volumes were rendered unusable by the failure despite the successful hot-spare procedure, the following message is included in the mail: The following RAID-5 volumes: volumename have subdisks on the replaced disk and have experienced other failures that prevent recovery. These RAID-5 volumes must have their data restored. If any volumes (RAID-5 or otherwise) were rendered unusable, the following message is also included: To restore the contents of any volumes listed above, the volume should be started with the command: vxvol -f start volumename and the data restored from backup. Sparelist File The sparelist file is a text file that specifies an ordered list of disks to be used as hot spares when a specific disk fails. The system- wide sparelist file is located in /etc/vx/sparelist. Each line in the sparelist file specifies a list of spares for one disk. Lines beginning with the pound (#) character and empty lines are ignored. The format for a line in the sparelist file is: [ diskgroup:] diskname : spare1 [ spare2 ... ] The diskgroup field, if present, specifies the disk group within which the disk and designated spares reside. If this field is not speci- fied, the default disk group is determined using the rules given in the vxdg(1M) manual page. The diskname specifies the disk for which spares are being designated. The spare list after the colon lists the disks to be used as hot spares. The list is order dependent; in case of failure of diskname, the spares are tried in order. A spare will be used only if it is a valid hot spare (see above). If the list is exhausted without finding any spares, the default policy of using the closest disk is used. FILES
/etc/vx/sparelist Specifies a list of disks to serve as hot spares for a disk. NOTES
The sparelist file is not checked in any way for correctness until a disk failure occurs. It is possible to inadvertently specify a non- existent disk or inappropriate disk or disk group. Malformed lines are also ignored. SEE ALSO
mailx(1), vxintro(1M), vxnotify(1M), vxrecover(1M), vxrelocd(1M), vxunreloc(1M) VxVM 5.0.31.1 24 Mar 2008 vxsparecheck(1M)
All times are GMT -4. The time now is 07:08 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy