Disk is predictive failure but LED is showing green.

Hi Linux Team

we use hpacucli ctrl all show config command find out the failure disk. Here command output is showing predictive failure but The Datacenter team are unable to find the correct failure disk. From Datacenter all LEDs are showing green.

Datacenter asks us to blink the LED.

How to blink the LED? what is the command to use.

Last edited by Naveen.6025; 08-29-2012 at 06:39 AM.. Reason: Linux OS
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Disk failure

is there anu way by which i can find out if all the disks on the system are working ? Milind Shauche. (2 Replies)
Discussion started by: shauche
2 Replies

2. HP-UX

Disk Failure

I am new to being a Unix admin and have a question about replacing some hardware. I have a K class box using HP-UX 10.20 with three disks. Two of the drives are in one logical volume. Every 3 or 4 days, the syslog is showing that one of these drives is experiencing "POWERFAILED" and then recovering... (6 Replies)
Discussion started by: SemiOfCol
6 Replies

3. Filesystems, Disks and Memory

Looking for a solution to disk failure!

Hi people, I have been using my disk for quite a long time but the other day I heard the drive making some noise and had to restart the system again. But when I did that the disk would not boot and I fear that the data might be deleted or lost. So, if you people have any know about the ways to get... (1 Reply)
Discussion started by: adam466
1 Replies

4. Filesystems, Disks and Memory

Looking for a solution to disk failure!

Hi people, I have been using my disk for quite a long time but the other day I heard the drive making some noise and had to restart the system again. But when I did that the disk would not boot and I fear that the data might be deleted or lost. So, if you people have any know about the ways to... (2 Replies)
Discussion started by: christopher4
2 Replies

5. Solaris

SAN disk failure

hi all, have a solaris 9 OS and a SAN disk which used to work fine is not getting picked up by my machine. can anyone point out things to check in order to troubleshoot this ?? thanks in advance. (3 Replies)
Discussion started by: cesarNZ
3 Replies

6. Solaris

Error LED showing on E250

I've got an old E250 server where a front error LED is showing. I've read through the Sun docs (Sun Enterprise 250 Server Owner's Guide - Sun Microsystems) but it's only the 'General fault' LED (About the Status and Control Panel (Sun Enterprise 250 Server Owner's Guide) - Sun Microsystems)... (2 Replies)
Discussion started by: aussieos
2 Replies

7. Solaris

iSCSI disk showing incorrect size

Hi, I have a very frustrating issue! I hope you guys can assist When a disk is presented out the iSCSI target display a lower disk capacity SOLARIS VERSION is SOLARIS 10 05/09 Kernel Patch 139555-31 ISCSI Patch 119090-31, 141878-11 Unix Commands To discover Target bash-3.00# i... (0 Replies)
Discussion started by: capitalexall
0 Replies

8. UNIX for Advanced & Expert Users

RAID5 multi disk failure

Hi there, Don't know if my title is relevant but I'm dealing with dangerous materials that I don't really know and I'm very afraid to mess anything up. I have a Debian 5.0.4 server with 4 x 1TB hard drives. I have the following mdstat Personalities : md1 : active raid1 sda1 sdd1... (3 Replies)
Discussion started by: chebarbudo
3 Replies

9. Shell Programming and Scripting

Gamit installation error: showing Failure in make_gamit -- install_software terminated

what i should to do next? read full query first please!! harshbhu@harshbhu:/usr/local/gg/10.6/updates/Source$ sudo ./install_software sudo: unable to resolve host harshbhu install_software version 2017/06/29 GAMIT and GLOBK to be installed into /usr/local/gg/10.6/updates/Source If... (0 Replies)
Discussion started by: ankit lohar
0 Replies

10. AIX

AIX hard disk failure

Hi all, I have encountered the issue with the hard disk, the disk is failed and need to replace by the new one. As my understanding, this is just to take out the failed disk and insert the new ones, and that's all. But the third party hardware vendor said, there should be another procedure... (9 Replies)
Discussion started by: Phat
9 Replies
mlib_SignalLPCAutoCorrel_F32(3MLIB)			    mediaLib Library Functions			       mlib_SignalLPCAutoCorrel_F32(3MLIB)

NAME
mlib_SignalLPCAutoCorrel_F32 - perform linear predictive coding with autocorrelation method SYNOPSIS
cc [ flag... ] file... -lmlib [ library... ] #include <mlib.h> mlib_status mlib_SignalLPCAutoCorrel_F32(mlib_f32 *coeff, const mlib_f32 *signal, void *state); DESCRIPTION
The mlib_SignalLPCAutoCorrel_F32() function performs linear predictive coding with autocorrelation method. In linear predictive coding (LPC) model, each speech sample is represented as a linear combination of the past M samples. M s(n) = SUM a(i) * s(n-i) + G * u(n) i=1 where s(*) is the speech signal, u(*) is the excitation signal, and G is the gain constants, M is the order of the linear prediction fil- ter. Given s(*), the goal is to find a set of coefficient a(*) that minimizes the prediction error e(*). M e(n) = s(n) - SUM a(i) * s(n-i) i=1 In autocorrelation method, the coefficients can be obtained by solving following set of linear equations. M SUM a(i) * r(|i-k|) = r(k), k=1,...,M i=1 where N-k-1 r(k) = SUM s(j) * s(j+k) j=0 are the autocorrelation coefficients of s(*), N is the length of the input speech vector. r(0) is the energy of the speech signal. Note that the autocorrelation matrix R is a Toeplitz matrix (symmetric with all diagonal elements equal), and the equations can be solved efficiently with Levinson-Durbin algorithm. See Fundamentals of Speech Recognition by Lawrence Rabiner and Biing-Hwang Juang, Prentice Hall, 1993. PARAMETERS
The function takes the following arguments: coeff The linear prediction coefficients. signal The input signal vector. state Pointer to the internal state structure. RETURN VALUES
The function returns MLIB_SUCCESS if successful. Otherwise it returns MLIB_FAILURE. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Interface Stability |Committed | +-----------------------------+-----------------------------+ |MT-Level |MT-Safe | +-----------------------------+-----------------------------+ SEE ALSO
mlib_SignalLPCAutoCorrelInit_F32(3MLIB), mlib_SignalLPCAutoCorrelGetEnergy_F32(3MLIB), mlib_SignalLPCAutoCorrelGetPARCOR_F32(3MLIB), mlib_SignalLPCAutoCorrelFree_F32(3MLIB), attributes(5) SunOS 5.11 2 Mar 2007 mlib_SignalLPCAutoCorrel_F32(3MLIB)
All times are GMT -4. The time now is 10:42 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy