Sponsored Content
Operating Systems Solaris i want to set ip address to a virtual machine Post 302692975 by bitlord on Tuesday 28th of August 2012 09:14:18 AM
Old 08-28-2012
Good Idea coolboys.
But you have a typo.
Code:
dladm show-dev

 

10 More Discussions You Might Find Interesting

1. IP Networking

sharing of IP address for load sharing avoiding virtual server & redirection machine

I have RedHat 9.0 installed on three of my servers (PIII - 233MHz) and want that they share a common IP address so that any request made reaches each of the servers. Can anyone suggest how should I setup my LAN. I'm new to networking in Linux so please elaborate and would be thankful for a timely... (2 Replies)
Discussion started by: Rakesh Ranjan
2 Replies

2. IP Networking

Virtual IP address

We currently have a Solaris Wks that is being used as an "ftp server" and it routinely accepts data each night that if ftp'd to it from off site. In the event that this "ftp server" should fail (crash, die, whatever) we would like to have an automatic fail over to a second Solaris Wks as the "ftp... (2 Replies)
Discussion started by: kanejm
2 Replies

3. Solaris

Is there any Virtual data center as we have Virtual Machine?

Do we have any Virtual Data Center software as we have Virtual Machine? I want to practice everything of Solaris practically but i don't have resources like data center which includes Servers, Data storages, switches, and other things. (2 Replies)
Discussion started by: karman0931
2 Replies

4. UNIX for Dummies Questions & Answers

Static IP address for solaris 10 virtual machine

Hi All I am having a solaris 10 virtual machine on vista (using vmware 7) laptop. Now i want to access virtual machine from vista using putty. Problem is that i insalled the solaris machine as dhcp. and whenever i connect to internet or reboot my system the IP address of solaris... (1 Reply)
Discussion started by: ankurk
1 Replies

5. UNIX for Dummies Questions & Answers

What would the physical address be for virtual address?

Hi guys, I got one problem which I definetily no idea. What would the physical address be for virtual address? 1) 2ABC 2) 3F4B Here is the page table:see attached Thank you sos sososososso much!! (0 Replies)
Discussion started by: lemon_06
0 Replies

6. UNIX for Dummies Questions & Answers

How to set server's ip address, router, network mask and set if it is an internal or external ip?

Hello, I need to write a program which sets server's ip address, router, network mask. Program also should set if it is an internal or external ip. Maybe someone can help me ? Any information from u is very useful :b: I stopped at .. :( #!/bin/sh A=`hostname -i` echo "server ip address is $A"... (4 Replies)
Discussion started by: zagaruika
4 Replies

7. Solaris

Change hostID of Solaris 10 virtual/guest machine installed by Virtual Box 4.1.12 on Windows-XP host

Trying to set or modify the randomly set hostID of a Solaris 10 virtual/guest machine that I installed on a Windows-XP host machine (using Virtual Box 4.1.12). I was able to set/modify the hostname of the Solaris 10 virtual/guest machine during installation as well as via the Virtual Box... (4 Replies)
Discussion started by: Matt_VB
4 Replies

8. Red Hat

My RHEL virtual Machine Does not have Virtual Machine Manager Desktop Tool

My RHEL virtual Machine Does not have Virtual Machine Manager Desktop Tool Hi, I don't seem to have the Virtual Machine Manager Desktop tool set up on my RHEL6 Machine. The Linux machine runs off VMWare player and I'm not sure whether it is a VMWare software issue or a problem with the RHEL6... (2 Replies)
Discussion started by: accipiter1
2 Replies

9. AIX

IBM Virtual Machine OS on intel x86 and x64? IBM AIX OS on IBM Virtual Machine?

Hi There, I have zero information and zero knowledge for IBM virtual machine except Amazon cloud and VMware ESXi (Only Linux OS available). Anyone could provide me the following answer - Can IBM VM been deploy on X86 and X64 (Intel Chip)? If answer is yes any chance to deploy AIX OS... (13 Replies)
Discussion started by: chenyung
13 Replies

10. UNIX for Beginners Questions & Answers

Providing virtual machine priority in kvm based virtual machines

Hi All, Is there any way I can prioritize my VMs when there is resource crunch in host machine so that some VMs will be allocated more vcpu, more memory than other VMs in kvm/qemu hypervisor based virtual machines? Lets say in my cloud environment my Ubuntu 16 compute hosts are running some... (0 Replies)
Discussion started by: SanjayK
0 Replies
dladm(1M)																 dladm(1M)

NAME
dladm - configure data-link interfaces SYNOPSIS
dladm show-link [-s [-i interval]] [-p] [name] dladm show-dev [-s [-i interval]] [-p] [dev] dladm create-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] -d dev [-d dev] ... key dladm delete-aggr [-t] [-R root-dir] key dladm add-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm remove-aggr [-t] [-R root-dir] -d dev [-d dev] ... key dladm modify-aggr [-t] [-R root-dir] [-P policy] [-l mode] [-T time] [-u address] key dladm show-aggr [-L] [-s [-i interval]] [-p] [key] dladm -? The dladm command is used to configure data-links. A configured data-link is represented in the system as a STREAMS DLPI (v2) interface which may be plumbed under protocol stacks such as TCP/IP. Each data-link relies on either a single network device or an aggregation of devices to send packets to or receive packets from a network. The dladm command operates on the following kinds of object: link Data-links, identified by a name aggr Aggregations of network devices, identified by a key dev Network devices, identified by concatenation of a driver name and an instance number Some devices do not support configurable data-links or aggregations. The fixed data-links provided by such devices can be viewed using dladm, but can not be configured. SUBCOMMANDS The following subcommands are supported: show-link Show configuration information for all data-links or the specified data-link. By default, the system is configured to have one data-link for each known network device. show-dev Shows information for all devices or the specified device. create-aggr Creates an aggregation using the given key value from as many dev objects as are specified. A data-link is created by default, and is given a name which is the concatenation of "aggr" and the key value of the aggregation. delete-aggr Deletes the specified aggregation. add-aggr Adds as many dev objects as are specified to the given aggregation. remove-aggr Removes as many dev objects as are specified from the given aggregation. modify-aggr Modifies the parameters of the given aggregation. show-aggr Shows configuration information for all aggregations or the specified aggregation. The following options are supported: -k key --key=key The key of an aggregation. This must be an integer value between 1 and 999. -d dev --dev=dev A device specifier. This must be a concatenation of the name and instance of the driver bound to the device. -P policy --policy=policy Specifies the port selection policy to use for load spreading of outbound traffic. The policy specifies which dev object is used to send packets. A policy consists of a list of one or more layers specifiers separated by commas. A layer specifier is one of the follow- ing: L2 Select outbound device according to source and destination MAC addresses of the packet. L3 Select outbound device according to source and destination IP addresses of the packet. L4 Select outbound device according to the upper layer protocol information contained in the packet. For TCP and UDP, this includes source and destination ports. For IPsec, this includes the SPI (Security Parameters Index.) For example, to use upper layer protocol information, the following policy can be used: -P L4 To use the source and destination MAC addresses as well as the source and destination IP addresses, the following policy can be used: -P L2,L3 -l mode --lacp-mode=mode Specifies whether LACP should be used and, if used, the mode in which it should operate. Legal values are off, active or passive. -T time --lacp-timer=time Specifies the LACP timer value. The legal values are short or long. -u address --unicast=address Specifies a fixed unicast address to be used for the aggregation. If this option is not specified then an address is automatically cho- sen from the set of addresses of the component devices. -L --lacp Specifies whether detailed LACP information should be displayed. -s --statistics Used with the show-link, show-aggr, or show-dev subcommands to show the statistics of data-links, aggregations or devices, respec- tively. -i interval --interval=interval Used with the -s option to specify an interval, in seconds, at which statistics should be displayed. If this option is not specified, statistics will only be displayed once. -t --temporary Specifies that the change is temporary. Temporary changes last until the next reboot. -R root-dir --root-dir=root-dir Specifies an alternate root directory where dladm applies changes. This can be useful in JumpStart scripts, where the root directory of the system being modified is mounted elsewhere. -p --parseable Specifies that configuration information should be displayed in parseable format. -? --help Displays help information. (Stops interpretation of subsequent arguments). EXAMPLES
Example 1: Configuring an aggregation To configure a data-link over an aggregation of devices bge0 and bge1 with key 1, enter the following command: # dladm create-aggr -d bge0 bge1 1 See attributes(5) for descriptions of the following attributes: /usr/sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsu | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ /sbin +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsr | +-----------------------------+-----------------------------+ |Interface Stability |Evolving | +-----------------------------+-----------------------------+ ifconfig(1M), attributes(5), dlpi(7P) NOTES
The configuration of all objects will persist across reboot. 28 Sep 2005 dladm(1M)
All times are GMT -4. The time now is 12:49 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy