I trust that the local fibre welding company sorted your problem. Usually costs £1,000 per half-day. The repair kit is rather expensive to own.
We had a case where BT arrived to install a 100-core telephone cable. Rather than use the vacant duct labelled for the purpose, they decided to pull their cable through a duct which was dedicated to inter-building fibre optic communications. When the cable jammed they used a van to pull the cable. They managed to knock out 13 sites by destroying multiple fibre optic cables. The cable duct lining was also destroyed in the process.
A £100,000 repair was carried out in just three days. This included excavating and repairing the damaged duct and replacing two miles of fibre optic cable). The "engineers" concerned were banned from site.
The second attempt to install the telephone cable was heavily supervised and went without incident.
7 More Discussions You Might Find Interesting
1. UNIX for Dummies Questions & Answers
hi. I am newbie in Unix. I wanted to install Free BSD 5.2.1 to my computer which winXp was already installed. But i couldn't.
I chose Standard. Then it said you are going to use dos style fdisk partitioning. Then a window displayed begining like this.
WARNING: A geometry of 155127/16/63 for... (0 Replies)
Discussion started by: sualcavab
0 Replies
2. Shell Programming and Scripting
Hi,
I have variables like mentioned below and want to separate as mentioned in output.
var1="4 x fibre cards"
var2="2 fibre cards"
var3="6 - fibre cards"
var4="4 x dual-port"
I have variables like this.I want to separate numbers from this and fibre cards from this.
output has to be... (4 Replies)
Discussion started by: ajilesh
4 Replies
3. AIX
Hello,
I have two systems that are being prepared to be SAN attached ..
can anyone tell me any specific checks I should perform prior to the cards being installed...
I am aware of firmware / OS level and relevant drivers, is there anything else?
thanks
Chris. (8 Replies)
Discussion started by: chlawren
8 Replies
4. Solaris
When loooking at files in a directory using ls, how can I tell if I have a hard link or soft link? (11 Replies)
Discussion started by: Harleyrci
11 Replies
5. AIX
Hi
I'm logged in as root in an aix box
Which command will list all the soft links and hard links present in the server ? (2 Replies)
Discussion started by: newtoaixos
2 Replies
6. Hardware
We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice?
Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies
7. AIX
Hi guys,
I've been trying to tackle this issue for days and I'm stumped. Hopefully someone can give more light on what else I can do.
I have a p7 series box, with dual VIOS and 10 lpars and everything was working fine until I had to move the box to another location in the data centre. Ensured... (16 Replies)
Discussion started by: aixkidbee
16 Replies
LEARN ABOUT DEBIAN
apcsmart-old
APCSMART-OLD(8) NUT Manual APCSMART-OLD(8)
NAME
apcsmart-old - Driver for American Power Conversion Smart Protocol UPS equipment
SYNOPSIS
apcsmart-old -h
apcsmart-old -a UPS_NAME [OPTIONS]
Note
This man page only documents the hardware-specific features of the apcsmart-old driver. For information about the core driver, see
nutupsdrv(8).
SUPPORTED HARDWARE
apcsmart-old should recognize all recent APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and
Back-UPS Pro lines.
The driver attempts to support every bell and whistle of the APC reporting interface, whether or not this is strictly sensible.
Some older hardware may only report a handful of variables. This is usually not a bug--they just don't support anything else.
CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the cable=
definition described below.
If your 940-0024C cable is broken or missing, use this diagram to build a clone:
http://www.networkupstools.org/cables/940-0024C.jpg
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5):
cable=940-0095B
Configure the serial port for the APC 940-0095B dual-mode cable.
sdtype=num
Use shutdown type num, according to this table:
0
soft shutdown or powerdown, depending on battery status
1
soft shutdown followed by powerdown
2
instant power off
3
power off with grace period
4
"force OB" hack method for CS 350
Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns.
Mode 4 exploits an oddity in the CS 350 models since they only seem to support the S command, but then only when running on battery. As a
result, the driver will force the UPS to go on battery if necessary before sending the shutdown command. This ensures that the load gets
reset.
BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but
some other unexpected values have occasionally slipped through.
APC UPS models with both USB and serial ports require a power cycle when switching from USB communication to serial, and perhaps vice
versa.
AUTHOR
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing heavily on the original apcsmart driver by Russell Kroll). This driver
was called newapc for a time and was renamed in the 1.5 series. In 2.6.2 the driver was renamed to apcsmart-old, being superseded by
updated version with new features.
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 APCSMART-OLD(8)