The Lounge War Stories How not to install fibre links between data centres! Post 302686933 by gull04 on Wednesday 15th of August 2012 04:49:57 PM
Old 08-15-2012
How not to install fibre links between data centres!

Hi Folks,

A couple of years ago we had to replace the core switches between two of our data centres, a simple task for the most part - these new switches would be state of the art Cisco Catalyst units.

The link between the two sites was a dark fibre, with 8Gb bandwidth running full duplex over a redundant cable pair. It was quite a surprise when we started to tidy up the cables to find this - see the attached images.

The cables comprised two male to male cables, with the ends joined with Bluetack. I'm amazed that it worked for so long. - Actually I'm amazed it worked at all!

Regards

Dave
How not to install fibre links between data centres!-bluetack_fairyjpg
How not to install fibre links between data centres!-bluetack_fairy_againjpg

Last edited by gull04; 08-15-2012 at 09:33 PM..
 

7 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

How to install FreeBSD without loosing my data?

hi. I am newbie in Unix. I wanted to install Free BSD 5.2.1 to my computer which winXp was already installed. But i couldn't. I chose Standard. Then it said you are going to use dos style fdisk partitioning. Then a window displayed begining like this. WARNING: A geometry of 155127/16/63 for... (0 Replies)
Discussion started by: sualcavab
0 Replies

2. Shell Programming and Scripting

4 x fibre cards elimination

Hi, I have variables like mentioned below and want to separate as mentioned in output. var1="4 x fibre cards" var2="2 fibre cards" var3="6 - fibre cards" var4="4 x dual-port" I have variables like this.I want to separate numbers from this and fibre cards from this. output has to be... (4 Replies)
Discussion started by: ajilesh
4 Replies

3. AIX

Install Fibre Card AIX 5.3

Hello, I have two systems that are being prepared to be SAN attached .. can anyone tell me any specific checks I should perform prior to the cards being installed... I am aware of firmware / OS level and relevant drivers, is there anything else? thanks Chris. (8 Replies)
Discussion started by: chlawren
8 Replies

4. Solaris

Hard Links and Soft or Sym links

When loooking at files in a directory using ls, how can I tell if I have a hard link or soft link? (11 Replies)
Discussion started by: Harleyrci
11 Replies

5. AIX

List all the soft links and hard links

Hi I'm logged in as root in an aix box Which command will list all the soft links and hard links present in the server ? (2 Replies)
Discussion started by: newtoaixos
2 Replies

6. Hardware

Fibre Channel HBA recommendations?

We will be buying new Xeon E5-based servers for our datacenter and were wondering which Fibre Channel host bus adapters we should select for these. The choices are Emulex or QLogic (8Gb FC HBAs). Anybody have any recommendations on which is the better choice? Thanks in advance. (1 Reply)
Discussion started by: atahmass
1 Replies

7. AIX

VIOS - fibre adapters not seeing luns

Hi guys, I've been trying to tackle this issue for days and I'm stumped. Hopefully someone can give more light on what else I can do. I have a p7 series box, with dual VIOS and 10 lpars and everything was working fine until I had to move the box to another location in the data centre. Ensured... (16 Replies)
Discussion started by: aixkidbee
16 Replies
APCSMART(8)						      Network UPS Tools (NUT)						       APCSMART(8)

NAME
apcsmart - Driver for American Power Conversion Smart Protocol UPS equipment NOTE
This man page only documents the hardware-specific features of the apcsmart driver. For information about the core driver, see nutups- drv(8). SUPPORTED HARDWARE
apcsmart should recognize all APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS and Matrix-UPS lines, but some Back-UPS Pro models are also supported. Some older hardware may only report a handful of variables. This is usually not a bug - they just don't support anything else. CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the cable= definition described below. If your 940-0024C cable is broken or missing, use this diagram to build a clone: http://www.exploits.org/nut/library/cables/940-0024C.jpg EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): cable=940-0095B Configure the serial port for the APC 940-0095B dual-mode cable. sdtype=num Use shutdown type num, according to this table: 0: soft shutdown or powerdown, depending on battery status 1: soft shutdown followed by powerdown 2: instant power off 3: power off with grace period Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns. BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but some other unexpected values have occasionally slipped through. AUTHOR
Russell Kroll SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/ NUT mailing list archives and information: http://lists.exploits.org/ Tue Oct 22 2002 APCSMART(8)
All times are GMT -4. The time now is 10:46 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy