Sponsored Content
Operating Systems Solaris Is it possible to set a PSU as faulty on Solaris Post 302686581 by justsam on Wednesday 15th of August 2012 01:00:39 AM
Old 08-15-2012
Is it possible to set a PSU as faulty on Solaris

Hi,

I'm trying to generate an alert related to Power Supply Failure.
As its difficult to generate such an event, Is it possible to set the status of a Power Supply Unit as "Faulty"

Any ideas are welcome and highly appreciated

-Thanks
 

10 More Discussions You Might Find Interesting

1. Solaris

Faulty PSU - but its still working !?!

Hello We have a power supply in an x4100 (x86) and it seems to be faulty but it is still working!?! (this box only has one PSU). We are getting Orange flashing warning light on the front of the box and the LED labelled “rear PSu” is solid orange ...We don't seem to have had any syslog error... (8 Replies)
Discussion started by: hcclnoodles
8 Replies

2. Solaris

Input power unavailable for PSU @ PS0

I have a question here about the OS logs (/var/adm/messages) where it should write most alarms. I ran a hardware test by showing the Power Supply redundancy. Removing PS0 while PS1 is still plugged in confirms that the system still operates with no problems. However, when it comes to logging, I... (1 Reply)
Discussion started by: gilberteu
1 Replies

3. Solaris

/usr/sap/psu file systems full.

Hi Ive been facing a prob today in SAP which is been installed in solaris .the prob is one of my file systems tat is /usr/sap/psu is gettin full.i chkd the file named core which gets generated so i was asked to delete that file after doing tat my file systems space was 90%,but the prob is that... (0 Replies)
Discussion started by: madanmeer
0 Replies

4. Solaris

PSU info M4/5/8/9000

I need to find out PSU info for some M class severs, normally prtdiag -v show's the relevant PS info, however these M classes don't seem to go down to that level !? Anyone any ideas , no physical or console access available at this stage :( thx... (3 Replies)
Discussion started by: itsupplies
3 Replies

5. Solaris

Reset PSU fault

Hi all, I have one Sun Oracle T5220 server with Solaris 10. On the front panel I saw the PSU fault led is steady with an orange color. So I checked the PSUs changed them and checked the "showfaults", "showfru" and some another commands, no problem. On the rear side I don't see any errors... (2 Replies)
Discussion started by: hubatuwang
2 Replies

6. Shell Programming and Scripting

shell script to check if PSU and fan needs to be replaced?

does anyone know any shell script command that can check if PSU and fan needs to be replaced? examples will also be greatly appreciated. thanks! (5 Replies)
Discussion started by: h0ujun
5 Replies

7. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

8. Red Hat

Check PSU Status

Hello, We have a cluster and each server have 2 PSU. An alarm should be raised in case of failure so we need to check periodically the PSU status wth a script. The first idea was to check with ipmitool but this take some time to get the data and we face some other issues now due to that... (1 Reply)
Discussion started by: @dagio
1 Replies

9. Solaris

PSU is bad?

Hello, When reviewing the messages log today I noted something odd, so I ran: /usr/lib/osa/bin/healthck -a and the response noted Failed Power Supply. Sure enough the light on the PSU is amber. Uh oh... In an effort to see if I can figure out what kinds of PSU we have, I found a... (2 Replies)
Discussion started by: madEG
2 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
pmconfig(1M)						  System Administration Commands					      pmconfig(1M)

NAME
pmconfig - Configure the Power Management system SYNOPSIS
/usr/sbin/pmconfig [-r] DESCRIPTION
The pmconfig utility sets the Power Management and suspend-resume configuration. User has permission to change Power Management configu- ration using pmconfig only if he is allowed to do so according to PMCHANGEPERM keyword of /etc/default/power. User has permission to change the suspend-resume configuration using pmconfig only if he is allowed to do so according to the CPRCHANGEPERM keyword of /etc/default/power. See FILES section below for a description of the PMCHANGEPERM and CPRCHANGEPERM keywords of /etc/default/power. Based on user permissions, pmconfig first resets the Power Management and/or suspend-resume state back to its default and then reads the new Power Management and/or suspend-resume configuration from /etc/power.conf and issues the commands to activiate the new configu- ration. The pmconfig utility is run at system boot. This utility can also be run from the command line after manual changes have been made to the /etc/power.conf file. For editing changes made to the /etc/power.conf file to take effect, users must run pmconfig. The preferred interface for changing Power Management and suspend-resume configuration is dtpower(1M). OPTIONS
The following options are supported: -r Reset Power Management and suspend-resume state to default and exit. User must have both Power Management and suspend-resume configuration permission for this option. EXIT STATUS
The following exit values are returned: 0 Upon successful completion >0 An error occurred FILES
/etc/power.conf System Power Management configuration file /etc/default/power File that controls permissions for system's Power Management and suspend-resume features. The PMCHANGEPERM key- board controls the Power Management configuration permissions, while the CPRCHANGEPERM keyword controls the sus- pend-resume configuration permissions. Allowed values are: all Any user can change the configuration. - No one except super-user can change the configuration. <user1, user2,...> A user in this user list or a super-user can change the configuration. The user list is a space and/or comma (,) separated list. You must enclose the list in < and > characters. console-owner A user who owns the system console device node or a super-user can change the configuration. The default values are PMCHANGEPERM=console-owner and CPRCHANGEPERM=console-owner. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWpmu | +-----------------------------+-----------------------------+ |Interface stability |Unstable | +-----------------------------+-----------------------------+ SEE ALSO
svcs(1), powerd(1M), power.conf(4), svcadm(1M), attributes(5), smf(5), cpr(7), pm(7D) Using Power Management NOTES
The pmconfig service is managed by the service management facility, smf(5), under the service identifier: svc:/system/power:default Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The ser- vice's status can be queried using the svcs(1) command. DIAGNOSTICS
If the program cannot open the configuration file, it prints an error message to standard error. If the program encounters a syntax error in the configuration file, it prints an error message and the line number of the error in the configuration file. It then skips the rest of the information on that line and processes the next line. Any configuration information already processed on the line containing the error is used. If user does not have permission to change Power Management and/or suspend-resume configuration, and configuration file has entries for which user doesn't have permission, it process the entries for which user has permissions and prints error on rest. SunOS 5.10 12 Aug 2004 pmconfig(1M)