Sponsored Content
Operating Systems SCO Recovery error : mit_hdpart0 failed Post 302684811 by mammut3d on Friday 10th of August 2012 05:55:19 AM
Old 08-10-2012
Recovery error : mit_hdpart0 failed

Hi,
I'm a new user of unix sco open server.
In my work place i had to recover a sco openserver backup into another PC but when i'm trying to do that i got this error message :Smilie
dparm: write ioctl failed: No such device or address
Invalid entry
mit_hdpart0 failed
Fatal Error: A critical disk initialization
utility has failed on the primary disk.
Error: /mitram/lib/mit_hd has failed, exiting with state FAIL

** Safe to Power Off **
-or-
** Press Any Key to Reboot **

----------- aditional information
using IDE HARD
Two computers are diffrent

Thank you and in advance please

Last edited by mammut3d; 08-10-2012 at 07:11 AM..
 

10 More Discussions You Might Find Interesting

1. UNIX for Advanced & Expert Users

Capturing failed FTP error

Hi All, Please check the below ftp related job, which is deleting the files from remote host. Problem is it is not capturing the ftp failure error, and the exit status is still '0' eventhough the deletable files are not present in remote location OR ftp credential are incorrect. ... (5 Replies)
Discussion started by: ganapati
5 Replies

2. Solaris

Reserve Failed error for HD

Hi Guys, Anybody come across this error when formating a harddisk. "Reserved Failed" Supected hardisk failure, is my assumption correct. Thanks (5 Replies)
Discussion started by: bigmoon
5 Replies

3. HP-UX

Compilation failed error

Hi, I have installed automake in one of HP-UX boxes using swinstall command. But when i issue automake it gives the following error message. Can't locate loadable object for module IO in @INC (@INC contains: /usr/local/share/automake-1.10 /usr/local/lib/perl5/5.8.8/PA-RISC2.0... (1 Reply)
Discussion started by: chrisanto_2000
1 Replies

4. UNIX for Advanced & Expert Users

nestat error (getnameinfo failed)

# netstat -a > /test/a getnameinfo failed getnameinfo failed getnameinfo failed getnameinfo failed getnameinfo failed command is working fine (as i get output in file /test/a) # dig -x 10.xxx.xxx.xxx ; <<>> DiG 9.3.3rc2 <<>> -x 10.203.xxx.xxx ;; global... (0 Replies)
Discussion started by: crackthehit007
0 Replies

5. Solaris

Cygwin X Server error: xdmcp fatal error session failed session 23 failed for display

Hi, i got the following error when i tried to access the cygwin x server from a windows XP PC. "xdmcp fatal error session failed session 23 failed for display" Alternatively, when i tried to access the same Cygwin X Server from another windows XP PC which is on a different LAN... (3 Replies)
Discussion started by: HarishKumarM
3 Replies

6. Solaris

Meaning of error-reset-recovery parameter in OK

Hi Could any one explain the meaning & purpose of below mention parameters in layman term. Suppose if we set below paramet what will happen. error-reset-recovery=boot error-reset-recovery=sync (3 Replies)
Discussion started by: sb200
3 Replies

7. Solaris

Rpcinfo: can't contact portmapper: RPC: Authentication error; why = Failed (unspecified error)

I have two servers with a fresh install of Solaris 11, and having problems when doing rpcinfo between them. There is no firewall involved, so everything should theoretically be getting through. Does anyone have any ideas? I did a lot of Google searches, and haven't found a working solution yet. ... (2 Replies)
Discussion started by: christr
2 Replies

8. Solaris

ERROR: Copy of CD image failed

Hi I tried to boot as single-user mode on my sunfire t1000 to change my root password since the guy has left the company without give us the root password. anyhow since this machine not have attached with cd/dvd/usb so the only think that to do it through Jumpstart now i tried to... (8 Replies)
Discussion started by: jmishal
8 Replies

9. UNIX for Advanced & Expert Users

ADSever error in ldap_connect failed

I have created a windows server 2008 r2 Active Directory Server where I will create users. These users will be AD owners of data created on SUSE-OES server. I am facing issue while while creating my suse-oes server account to ade server. When I try to join my linux box to this windows AD... (0 Replies)
Discussion started by: rupeshkp728
0 Replies

10. HP-UX

Expert Recovery Shell - Fatal Error: Unrecognized disk layout

I have a B.11.31 U ia64 system where I swremove the disk driver "SerialSCSI-00 B.11.31.1303 PCI-X/PCI-E SerialSCSI" (by mistake). afterwards the system won;t boot because of the missing disk drivers. I'm trying to recover my kernel by using the image HP-ux_11_31_disc_1.iso Run an Expert... (1 Reply)
Discussion started by: black_fender
1 Replies
MLY(4)							   BSD Kernel Interfaces Manual 						    MLY(4)

NAME
mly -- Mylex AcceleRAID/eXtremeRAID family driver SYNOPSIS
mly* at pci? dev ? function ? scsibus* at mly? DESCRIPTION
The mly driver provides support for Mylex AcceleRAID and eXtremeRAID family of PCI to SCSI RAID controllers with version 6.00 and later firmware. Supported controllers include: o AcceleRAID 160 o AcceleRAID 170 o AcceleRAID 352 o eXtremeRAID 2000 o eXtremeRAID 3000 Compatible Mylex controllers not listed should work, but have not been tested. Logical devices (disk arrays) attached to the controller are presented to the SCSI subsystem as though they were direct-access devices on a virtual SCSI bus. Physical devices which are not claimed by a logical device are presented on SCSI channels which match the physical chan- nels on the controller. The results of the SCSI ``INQUIRY'' command from logical devices are overwritten with status information by the mly driver. The vendor field is the string ``MYLEX'', the product field indicates the type of logical device, and the revision field contains a four letter status code. The possible status codes and their meanings are as follows: OFLN offline UNCF unconfigured ONLN online - optimal CRIT critical - one or more disks in the array has failed NORD write only STBY standby MISS missing DIAGNOSTICS
Controller initialization phase mly%d: controller initialization started mly%d: initialization complete The controller firmware has started initialization. Normally this process is performed by the controller BIOS, but the driver may need to do this in cases where the BIOS has failed, or is not compatible (e.g. on non-x86 systems). mly%d: drive spinup in progress Drive startup is in progress; this may take several minutes. mly%d: mirror race recovery failed, one or more drives offline mly%d: mirror race recovery in progress mly%d: mirror race recovery on a critical drive These error codes are undocumented. mly%d: FATAL MEMORY PARITY ERROR Firmware detected a fatal memory error; the driver will not attempt to attach to this controller. mly%d: unknown initialization code %x An unknown error occurred during initialization; it will be ignored. Operational diagnostics mly%d: physical device %d:%d online mly%d: physical device %d:%d standby mly%d: physical device %d:%d automatic rebuild started mly%d: physical device %d:%d manual rebuild started mly%d: physical device %d:%d rebuild completed mly%d: physical device %d:%d rebuild cancelled mly%d: physical device %d:%d rebuild failed for unknown reasons mly%d: physical device %d:%d rebuild failed due to new physical device mly%d: physical device %d:%d rebuild failed due to logical drive failure mly%d: physical device %d:%d found mly%d: physical device %d:%d gone mly%d: physical device %d:%d unconfigured mly%d: physical device %d:%d expand capacity started mly%d: physical device %d:%d expand capacity completed mly%d: physical device %d:%d expand capacity failed mly%d: physical device %d:%d parity error mly%d: physical device %d:%d soft error mly%d: physical device %d:%d miscellaneous error mly%d: physical device %d:%d reset mly%d: physical device %d:%d active spare found mly%d: physical device %d:%d warm spare found mly%d: physical device %d:%d initialization started mly%d: physical device %d:%d initialization completed mly%d: physical device %d:%d initialization failed mly%d: physical device %d:%d initialization cancelled mly%d: physical device %d:%d write recovery failed mly%d: physical device %d:%d scsi bus reset failed mly%d: physical device %d:%d double check condition mly%d: physical device %d:%d device cannot be accessed mly%d: physical device %d:%d gross error on scsi processor mly%d: physical device %d:%d bad tag from device mly%d: physical device %d:%d command timeout mly%d: physical device %d:%d system reset mly%d: physical device %d:%d busy status or parity error mly%d: physical device %d:%d host set device to failed state mly%d: physical device %d:%d selection timeout mly%d: physical device %d:%d scsi bus phase error mly%d: physical device %d:%d device returned unknown status mly%d: physical device %d:%d device not ready mly%d: physical device %d:%d device not found at startup mly%d: physical device %d:%d COD write operation failed mly%d: physical device %d:%d BDT write operation failed mly%d: physical device %d:%d missing at startup mly%d: physical device %d:%d start rebuild failed due to physical drive too small mly%d: physical device %d:%d sense data received mly%d: sense key %d asc %02x ascq %02x mly%d: info %4D csi %4D mly%d: physical device %d:%d offline mly%d: sense key %d asc %02x ascq %02x mly%d: info %4D csi %4D The reported event refers to the physical device at the given channel:target address. mly%d: logical device %d:%d consistency check started mly%d: logical device %d:%d consistency check completed mly%d: logical device %d:%d consistency check cancelled mly%d: logical device %d:%d consistency check completed with errors mly%d: logical device %d:%d consistency check failed due to logical drive failure mly%d: logical device %d:%d consistency check failed due to physical device failure mly%d: logical device %d:%d automatic rebuild started mly%d: logical device %d:%d manual rebuild started mly%d: logical device %d:%d rebuild completed mly%d: logical device %d:%d rebuild cancelled mly%d: logical device %d:%d rebuild failed for unknown reasons mly%d: logical device %d:%d rebuild failed due to new physical device mly%d: logical device %d:%d rebuild failed due to logical drive failure mly%d: logical device %d:%d offline mly%d: logical device %d:%d critical mly%d: logical device %d:%d online mly%d: logical device %d:%d initialization started mly%d: logical device %d:%d initialization completed mly%d: logical device %d:%d initialization cancelled mly%d: logical device %d:%d initialization failed mly%d: logical device %d:%d found mly%d: logical device %d:%d gone mly%d: logical device %d:%d expand capacity started mly%d: logical device %d:%d expand capacity completed mly%d: logical device %d:%d expand capacity failed mly%d: logical device %d:%d bad block found mly%d: logical device %d:%d size changed mly%d: logical device %d:%d type changed mly%d: logical device %d:%d bad data block found mly%d: logical device %d:%d read of data block in bdt mly%d: logical device %d:%d write back data for disk block lost The reported event refers to the logical device at the given channel:target address. mly%d: enclosure %d fan %d failed mly%d: enclosure %d fan %d ok mly%d: enclosure %d fan %d not present mly%d: enclosure %d power supply %d failed mly%d: enclosure %d power supply %d ok mly%d: enclosure %d power supply %d not present mly%d: enclosure %d temperature sensor %d failed mly%d: enclosure %d temperature sensor %d critical mly%d: enclosure %d temperature sensor %d ok mly%d: enclosure %d temperature sensor %d not present mly%d: enclosure %d unit %d access critical mly%d: enclosure %d unit %d access ok mly%d: enclosure %d unit %d access offline These events refer to external enclosures by number. The driver does not attempt to name the enclosures. mly%d: controller cache write back error mly%d: controller battery backup unit found mly%d: controller battery backup unit charge level low mly%d: controller battery backup unit charge level ok mly%d: controller installation aborted mly%d: controller mirror race recovery in progress mly%d: controller mirror race on critical drive mly%d: controller memory soft ecc error mly%d: controller memory hard ecc error mly%d: controller battery backup unit failed These events report controller status changes. SEE ALSO
cd(4), ch(4), intro(4), mlx(4), scsi(4), sd(4), st(4), scsictl(8) HISTORY
The mly driver first appeared in NetBSD 1.6, and was based on the FreeBSD driver of the same name. BUGS
The mly driver currently assumes that all busses support at most 16 targets and 1 logical unit per target. Enclosures are not named or otherwise identified in event messages. The transfer speed for devices is always reported to the kernel as 20MHz. BSD
July 29, 2001 BSD
All times are GMT -4. The time now is 05:54 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy