Sun cluster 4.0 - zone cluster failover doubt
Hello experts -
I am planning to install a Sun cluster 4.0 zone cluster fail-over. few basic doubts.
(1) Where should i install the cluster s/w binaries ?. ( global zone or the container zone where i am planning to install the zone fail-over)
(2) Or should i perform the installation on both. (Global zone and container zone).
(3) Can i have the cluster installed only in the zone and not the Global zone.
Kindly clarify the basics for me.
Thank you...
Thx,
NVA
Last edited by DukeNuke2; 08-09-2012 at 07:56 PM..
10 More Discussions You Might Find Interesting
1. High Performance Computing
I have rcently setup a 4 node cluster running sun cluster 3.2
and I have installed 4 zones on each node. when installing the zones I had to install the zone on all nodes the on the last node do a zlogin -C <zonename>
this worked ok.
theni I tried to siwitch the zone to node a thei work... (14 Replies)
Discussion started by: lesliek
14 Replies
2. High Performance Computing
Dear All,
Can anyone explain about Pros and Cons of SUN and Veritas Cluster ?
Any comparison chart is highly appreciated.
Regards,
RAA (4 Replies)
Discussion started by: RAA
4 Replies
3. High Performance Computing
I have just completed a first RTFM of "Veritas Cluster Server Management Console Implementation Guide" 5.1, with a view to assessing it to possibly make our working lives easier.
Unfortunately, at my organisation, getting a test installation would be worse than pulling teeth, so I can't just go... (2 Replies)
Discussion started by: Beast Of Bodmin
2 Replies
4. Solaris
Hi,
We have two sun SPARC server in Clustered (Sun Cluster 3.1). For some reason, System 1 failed over to System 2. Where can I find the logs which could tell me the reason for this failover?
Thanks (5 Replies)
Discussion started by: Mack1982
5 Replies
5. Solaris
Yesterday my customer told me to expect a vcs upgrade to happen in the future. He also plans to stop using HDS and move to EMC.
Am thinking how to migrate to sun cluster setup instead.
My plan as follows leave the existing vcs intact as a fallback plan.
Then install and build suncluster on... (5 Replies)
Discussion started by: sparcguy
5 Replies
6. Gentoo
How to failover the cluster ? GNU/Linux
By which command,
My Linux version
2008 x86_64 x86_64 x86_64 GNU/Linux
What are the prerequisites we need to take while failover ?
if any
Regards (3 Replies)
Discussion started by: sidharthmellam
3 Replies
7. Solaris
HI Experts,
Could some one help me in configuring high availability zone on Sun Cluster
Reg: Sudhan (3 Replies)
Discussion started by: sudhan143
3 Replies
8. Solaris
Dear Experts,
If there is a possible Solaris Cluster failover to second node based on scan rate?
I need the documentation If solaris cluster can do this.
Thank You in Advance
Edy (3 Replies)
Discussion started by: edydsuranta
3 Replies
9. Red Hat
Hi Guys,
I am not much aware of clusters but i have few questions can someone provide the overview as it would be very helpful for me.
How can i perform cluster failover test to see all the services are failing back to other node ? If it is using veritas cluster then what kind of... (2 Replies)
Discussion started by: munna529
2 Replies
10. Solaris
Hi Gurus
I am not able to find the patching procedure for solaris 10 ( sol10 u11) to latest patchset with sun cluster having failover zones so that same I should follow.
Take an instance, there are sol1 and sol2 nodes and having two failover zones like sozone1-rg and sozone2-rg and currently... (1 Reply)
Discussion started by: nick101
1 Replies
LEARN ABOUT HPUX
named-checkzone
named-checkzone(1) General Commands Manual named-checkzone(1)
NAME
named-checkzone - zone validity checking tool
SYNOPSIS
class] mode] mode] outfile] directory] directory] zonename [filename]
DESCRIPTION
is a tool for performing integrity checks on the zone contents. It uses the same integrity checks as the daemon when loading a zone. This
makes useful for checking zone files before configuring them into a name server. Zones and zone files are described in named.conf(4).
Options
Specify the class of the zone.
Dump the zone file in canonical format.
Enable debugging.
Read the journal (if it exists) when loading the zone file.
Perform checks with the specified failure mode. Possible modes are (default), and The option is described in named.conf(4).
Specify whether NS records should be checked to see if they are addresses.
Possible modes are (default), and
Write zone output to
outfile .
Enable quiet mode for exit code only.
Print the version of
and exit.
Change to directory (see chdir(2)) so that relative file names in master file directives work This is similar to the clause in
Operands
filename The file to use for checking the zone contents. The default is the file with the zone name. For the default to work, the file
name for the zone in the statement of the file must be identical to the zone name.
zonename The zone whose contents are to be checked.
RETURN VALUE
sets the exit status to:
Success.
Errors were detected.
EXAMPLES
To perform integrity checks on zone in the zone file and display debug information:
AUTHOR
was developed by the Internet Systems Consortium (ISC).
SEE ALSO
named(1M), chdir(2), named.conf(4).
Requests for Comments (RFC): 1035, available online at
available online at
available from the Internet Systems Consortium at
BIND 9.3 named-checkzone(1)