08-05-2012
If you can put a remote console card in the system.
For Dell this would be iDRAC
HP would be iLO
You can do cold power off, come back later when you feel like it and power on.
If your HW supports it, wakeonlan could be another option.
9 More Discussions You Might Find Interesting
1. Shell Programming and Scripting
Hi,
In below code, i am expecting the output has
Bye
Bye
But i am getting has
Bye
Hi
Code:
#!/usr/bin/bash
var="Hi"
cat txt.txt | while read var1
do
next="Bye"
case $var in
Hi) (1 Reply)
Discussion started by: Balamani
1 Replies
2. IP Networking
I would like to find a switch port( of a VLAN of CISCO switch) of a machine which is acutally running under VMware.
Now I only know about IP & MAC address of a machine which running under VMware
and I do not know about the real machine where VMware is installed.
Is there any possibility? (2 Replies)
Discussion started by: Tlogine
2 Replies
3. Shell Programming and Scripting
Hi All,
I have written a script for a particular user say tren212 ,which checks the disk space of the user.
I wish to check the disk space of another user say tren213 in the same script.
How can I do the same?
I have tried using su command but it asks for the password at the... (4 Replies)
Discussion started by: Taranjeet Singh
4 Replies
4. Shell Programming and Scripting
Hi,
I am new to UNIX shell script programming.
I am using "putty" software to login remote UNIX system(123.com) . After login , i want to switch to another remote UNIX system (124.com) in same "putty" window.
Could you Please let me know how to do and very thankful if anyone provide... (1 Reply)
Discussion started by: jagadish.g
1 Replies
5. Shell Programming and Scripting
Hi All..
Am new to Unix!!
Am creating a shell script in which a scenario is like i have transfer the output file from unix machine (Server) to local directory (Windows xp).
And also i have to transfer the input file from the local directory to Unix machine (Server)
Any help from you... (1 Reply)
Discussion started by: vidhyaS
1 Replies
6. Shell Programming and Scripting
Below UNIX script abruptly ends while reading second line from file. When I comment 'ssh' command the script works as expected. I think I will have to run ssh command in a different process, but haven't got a handle yet as regards to how to do that. Any help in resolving this problem is highly... (1 Reply)
Discussion started by: jeeteshkc
1 Replies
7. Programming
Hello friends,
I started my career with VB.6.0 in 2007, In 2008 moved in VB.NET window application programming and then for web application programming with C#,ASP.NET with different databse like Oracle,MySQL and SQL Server.Currently I have 4.7 years experience in .NET application and worked... (8 Replies)
Discussion started by: Amit Verma
8 Replies
8. Shell Programming and Scripting
Hi Team,
Need your help for the below code snippet. I wrote a module to read the file names remote server using file name convention.
Issue : My script is coming out from while loop without reading complete file.
test1()
{
while read line
do
echo $line
file_nm_convention=`echo... (3 Replies)
Discussion started by: gvkumar25
3 Replies
9. SCO
I have inherited and SCO OpenServer Release 6 server. The clients connect using telnet to get to a proprietary database application for Service tickets. The issue I am currently having is that the connection just stops abruptly and you can see "telnet session terminated" on the terminal emulation... (22 Replies)
Discussion started by: sean6605
22 Replies
LEARN ABOUT REDHAT
newapc
NEWAPC(8) Network UPS Tools (NUT) NEWAPC(8)
NAME
newapc - Driver for American Power Conversion Smart Protocol UPS equipment
NOTE
This man page only documents the hardware-specific features of the newapc driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
newapc should recognize all recent APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS, Matrix-UPS and
Back-UPS Pro lines. Older APC models may work better with the apcsmart driver.
The driver attempts to support every bell and whistle of the APC reporting interface, whether or not this is strictly sensible.
Some older hardware may only report a handful of variables. This is usually not a bug - they just don't support anything else.
CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the
cable= definition described below.
If your 940-0024C cable is broken or missing, use this diagram to build a clone:
http://www.exploits.org/nut/library/cables/940-0024C.jpg
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5):
cable=940-0095B
Configure the serial port for the APC 940-0095B dual-mode cable.
sdtype=num
Use shutdown type num, according to this table:
0: soft shutdown or powerdown, depending on battery status
1: soft shutdown followed by powerdown
2: instant power off
3: power off with grace period
Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns.
BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but
some other unexpected values have occasionally slipped through.
AUTHOR
Nigel Metheringham <Nigel.Metheringham@Intechnology.co.uk> (drawing heavily on the apcsmart driver by Russell Kroll).
SEE ALSO
The core driver:
nutupsdrv(8)
The apcsmart driver:
apcsmart(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/
NUT mailing list archives and information: http://lists.exploits.org/
Tue Oct 22 2002 NEWAPC(8)