08-02-2012
By issuing multipath -l and checking /etc/multipath.confconfiguration file.
Regards
Peasant.
10 More Discussions You Might Find Interesting
1. Solaris
Hi everyone,
I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN?
At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies
2. Solaris
Hi there
Now, Ive always support servers that used multi path software with dual cards, e.g. powerpath (emc ) / MPXIO. I got asked a question today, that if a solaris 8/9/10 host had 2 HBA cards, but no multipathing software, what would happen ?? Does the HBA card with the highest id on the... (2 Replies)
Discussion started by: sbk1972
2 Replies
3. AIX
Hi,everyone
the situation is: at the very beginning ,through cfgmgr i find all LTO3 drives and 9840D drives. Then, some guy changed the device id(loop id) of all the stk drives on the tape lib panel. This time, i ran the cfgmgr but got nothing.
so i asked that guy to change the loop id... (2 Replies)
Discussion started by: zzisking
2 Replies
4. AIX
How to find the status of SAN Disc through command prompt (1 Reply)
Discussion started by: AIXlearner
1 Replies
5. AIX
Can someone point me in the right direction as to where I can find information on how to cleanly disconnect my AIX 5.3 host from our DS/4200 SAN. I have to do a firmware upgrade on the SAN.
-Thanks (2 Replies)
Discussion started by: tfort73
2 Replies
6. Solaris
We have a Sun M5000 connecting to a Brocade SAN switch. I don't know the IP of the Brocade switch and don't want to use its serial port to get the info. How can I find the IP of the Brocade switch under Solaris 10? Snoop is not supported by Solaris multipathing. What other tools can I use to find... (6 Replies)
Discussion started by: aixlover
6 Replies
7. UNIX for Advanced & Expert Users
Hello,
I would like to create a shell script which would check whether the hosts have SAN dual path or not. If yes, then I should get a success message, else should get a list of hosts on which SAN dual path is not working.
Thanks.. (4 Replies)
Discussion started by: mahive
4 Replies
8. Shell Programming and Scripting
If I enter (simplified):
find . -printf "%p\n"
then all files in the output are prepended by a "." like
./local/share/test23.log
How can achieve that
a.) the leading "./" is omitted
and/or
b.) the full path to the current directory is inserted (enclosed by brackets and a blank)... (1 Reply)
Discussion started by: pstein
1 Replies
9. Linux
Is there a command I can run on my HP /LINUX to see if uses SAN? This command work son AIX ls -al /DEV/rdsk however it does not work on HP Linux. Please let me know?
Thanks (4 Replies)
Discussion started by: mrn6430
4 Replies
10. Filesystems, Disks and Memory
hi! i got a rhel 6.3 host that already have an xfs filesystem mounted from a SAN (let's call it SAN-1) whose size is 9TB.
i will be receiving another SAN (let's call it SAN-2) storage of 15TB size. this new addition is physically on another SAN storage. SAN-1 is on a Pillar storage while the new... (6 Replies)
Discussion started by: rino19ny
6 Replies
LEARN ABOUT SUSE
multipath
MULTIPATH(8) Linux Administrator's Manual MULTIPATH(8)
NAME
multipath - Device mapper target autoconfig
SYNOPSIS
multipath [-v verbosity] [-d] [-h|-l|-ll|-f|-t|-F] [-p failover|multibus|group_by_serial|group_by_prio|group_by_node_name] [device]
DESCRIPTION
multipath is used to detect multiple paths to devices for fail-over or performance reasons and coalesces them
OPTIONS
-v level
verbosity, print all paths and multipaths
0 no output
1 print the created or updated multipath names only, for use to feed other tools like kpartx
2 + print all info : detected paths, coalesced paths (ie multipaths) and device maps
-h print usage text
-d dry run, do not create or update devmaps
-l show the current multipath topology from information fetched in sysfs and the device mapper
-ll show the current multipath topology from all available information (sysfs, the device mapper, path checkers ...)
-f flush a multipath device map specified as parameter, if unused
-F flush all unused multipath device maps
-t print internal hardware table to stdout
-p policy
force maps to specified policy:
failover 1 path per priority group
multibus all paths in 1 priority group
group_by_serial
1 priority group per serial
group_by_prio
1 priority group per priority value. Priorities are determined by callout programs specified as a global, per-con-
troller or per-multipath option in the configuration file
group_by_node_name
1 priority group per target node name. Target node names are fetched in /sys/class/fc_transport/target*/node_name.
device update only the devmap the path pointed by device is in. device is in the /dev/sdb (as shown by udev in the $DEVNAME variable) or
major:minor format. device may alternatively be a multipath mapname
SEE ALSO
multipathd(8), multipath.conf(5), kpartx(8), udev(8), dmsetup(8) hotplug(8)
AUTHORS
multipath was developed by Christophe Varoqui, <christophe.varoqui@free.fr> and others.