Old 08-02-2012
By issuing multipath -l and checking /etc/multipath.confconfiguration file.

Regards
Peasant.
 

10 More Discussions You Might Find Interesting

1. Solaris

Thoughts/experiences of SAN attaching V880 to EMC SAN

Hi everyone, I wonder if I can canvas any opinions or thoughts (good or bad) on SAN attaching a SUN V880/490 to an EMC Clarion SAN? At the moment the 880 is using 12 internal FC-AL disks as a db server and seems to be doing a pretty good job. It is not I/O, CPU or Memory constrained and the... (2 Replies)
Discussion started by: si_linux
2 Replies

2. Solaris

2 x HBA, connected to a SAN, but no Multi path software - What happens ?

Hi there Now, Ive always support servers that used multi path software with dual cards, e.g. powerpath (emc ) / MPXIO. I got asked a question today, that if a solaris 8/9/10 host had 2 HBA cards, but no multipathing software, what would happen ?? Does the HBA card with the highest id on the... (2 Replies)
Discussion started by: sbk1972
2 Replies

3. AIX

can't find a LTO3 drive through SAN,pls help!

Hi,everyone the situation is: at the very beginning ,through cfgmgr i find all LTO3 drives and 9840D drives. Then, some guy changed the device id(loop id) of all the stk drives on the tape lib panel. This time, i ran the cfgmgr but got nothing. so i asked that guy to change the loop id... (2 Replies)
Discussion started by: zzisking
2 Replies

4. AIX

How to find the status of SAN Disc through command prompt

How to find the status of SAN Disc through command prompt (1 Reply)
Discussion started by: AIXlearner
1 Replies

5. AIX

Find information for Host and SAN disconnect

Can someone point me in the right direction as to where I can find information on how to cleanly disconnect my AIX 5.3 host from our DS/4200 SAN. I have to do a firmware upgrade on the SAN. -Thanks (2 Replies)
Discussion started by: tfort73
2 Replies

6. Solaris

Find Brocade SAN switch’s IP in Sun server?

We have a Sun M5000 connecting to a Brocade SAN switch. I don't know the IP of the Brocade switch and don't want to use its serial port to get the info. How can I find the IP of the Brocade switch under Solaris 10? Snoop is not supported by Solaris multipathing. What other tools can I use to find... (6 Replies)
Discussion started by: aixlover
6 Replies

7. UNIX for Advanced & Expert Users

Shell script to check the SAN dual path.

Hello, I would like to create a shell script which would check whether the hosts have SAN dual path or not. If yes, then I should get a success message, else should get a list of hosts on which SAN dual path is not working. Thanks.. (4 Replies)
Discussion started by: mahive
4 Replies

8. Shell Programming and Scripting

"find . -printf" without prepended "." path? Getting path to current working directory?

If I enter (simplified): find . -printf "%p\n" then all files in the output are prepended by a "." like ./local/share/test23.log How can achieve that a.) the leading "./" is omitted and/or b.) the full path to the current directory is inserted (enclosed by brackets and a blank)... (1 Reply)
Discussion started by: pstein
1 Replies

9. Linux

How to Find out if an HP/Linux uses SAN or not?

Is there a command I can run on my HP /LINUX to see if uses SAN? This command work son AIX ls -al /DEV/rdsk however it does not work on HP Linux. Please let me know? Thanks (4 Replies)
Discussion started by: mrn6430
4 Replies

10. Filesystems, Disks and Memory

Faster way: SAN hd to SAN hd copying

hi! i got a rhel 6.3 host that already have an xfs filesystem mounted from a SAN (let's call it SAN-1) whose size is 9TB. i will be receiving another SAN (let's call it SAN-2) storage of 15TB size. this new addition is physically on another SAN storage. SAN-1 is on a Pillar storage while the new... (6 Replies)
Discussion started by: rino19ny
6 Replies
norewind_close_disabled(5)					File Formats Manual					norewind_close_disabled(5)

NAME
norewind_close_disabled - determine whether access to tape device special files without the no-rewind-on-close option is allowed VALUES
Default Allowed values DESCRIPTION
Note: this tunable was named in releases prior to HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on, the tape driver will fail any open on a tape device special file that does not have the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued accidentally from this system on close, possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. EXAMPLES
Query the current value of the tunable: Set the value of the tunable to To save the value of the tunable across reboots: WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters norewind_close_disabled(5)
All times are GMT -4. The time now is 05:58 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy