07-30-2012
Sorted now guys, not sure what it was as we pulled the controller and the disks and I think this forced a reset (array is DR stock so not in use). Controller has come back to life so I am thinking firware updates.
Thanks for your help
Rgrds
Martin
9 More Discussions You Might Find Interesting
1. Solaris
I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it.
I have one StorageTek 2540 array that I would like to connect to the T2000.
For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies
2. Solaris
We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey.
Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)?
One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies
3. Filesystems, Disks and Memory
Hi,
We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies
4. Solaris
Hi,
I have a simple question on how to correctly disable the matrix?
Looking for the Common Array Manager and I do not see this option...
Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies
5. Solaris
Hi peeps,
Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables.
Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies
6. Hardware
Hello all !
I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server.
I... (2 Replies)
Discussion started by: acorradi
2 Replies
7. Hardware
Hi all,
My Sun StorageTek 2540 have redundant batteries, but a battery was failed.
# /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru
Name FRU Alarm State Status Revision Unique Id
-------------------------- ----------- --------... (2 Replies)
Discussion started by: buyantugs
2 Replies
8. Solaris
Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun.
We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies
9. Solaris
Hi Guys,
I have situation here ...
server M4000 server lost connectivity to storagetek 2540
, storagetek 2540 unable to be ping.From DAS URL the storage is undetected.
Any idea why this is happening. Please share.
Thank you.
Raj (1 Reply)
Discussion started by: muralirajah
1 Replies
LEARN ABOUT DEBIAN
tie::array::sorted
Tie::Array::Sorted(3pm) User Contributed Perl Documentation Tie::Array::Sorted(3pm)
NAME
Tie::Array::Sorted - An array which is kept sorted
SYNOPSIS
use Tie::Array::Sorted;
tie @a, "Tie::Array::Sorted", sub { $_[0] <=> $_[1] };
push @a, 10, 4, 7, 3, 4;
print "@a"; # "3 4 4 7 10"
DESCRIPTION
This presents an ordinary array, but is kept sorted. All pushes and unshifts cause the elements in question to be inserted in the appropri-
ate location to maintain order.
Direct stores ("$a[10] = "wibble"") effectively splice out the original value and insert the new element. It's not clear why you'd want to
use direct stores like that, but this module does the right thing if you do.
If you don't like the ordinary lexical comparator, you can provide your own; it should compare the two elements it is given. For instance,
a numeric comparator would look like this:
tie @a, "Tie::Array::Sorted", sub { $_[0] <=> $_[1] }
Whereas to compare a list of files by their sizes, you'd so something like:
tie @a, "Tie::Array::Sorted", sub { -s $_[0] <=> -s $_[1] }
LAZY SORTING
If you do more stores than fetches, you may find Tie::Array::Sorted::Lazy more efficient.
AUTHOR
Original author: Simon Cozens
Current maintainer: Tony Bowden
BUGS and QUERIES
Please direct all correspondence regarding this module to: bug-Tie-Array-Sorted@rt.cpan.org
This module was originall written as part of the Plucene project. However, as Plucene no longer uses this, it is effectively unmaintained.
COPYRIGHT AND LICENSE
Copyright (C) 2003-2006 Simon Cozens and Tony Bowden.
This program is free software; you can redistribute it and/or modify it under
the terms of the GNU General Public License; either version 2 of the License,
or (at your option) any later version.
This program is distributed in the hope that it will be useful, but WITHOUT
ANY WARRANTY; without even the implied warranty of MERCHANTABILITY or FITNESS
FOR A PARTICULAR PURPOSE.
perl v5.8.8 2004-10-10 Tie::Array::Sorted(3pm)