07-26-2012
Storagetek 2540
Hi Guys and Gals,
Wionder if you could help me, got a problem with a controller on a storagetek 2540, dead when fully powered up but if you reboot, it is ok for a couple of seconds (and you can ping it). Then once the array is fully up, it goes faulty and is un-pingable.
Had anyone experienced this? Did they resolve it or is the controller stuffed and needs replacing?
Thanks in advance
Rgrds
Martin
9 More Discussions You Might Find Interesting
1. Solaris
I have a Sun Sparc T2000 (Solaris 10 05-08) and have installed a PCI-X 4GB Single Port HBA card in it.
I have one StorageTek 2540 array that I would like to connect to the T2000.
For the moment it would be a single path connection, but I've ordered a 2nd HBA, so eventually it would be... (4 Replies)
Discussion started by: soliberus
4 Replies
2. Solaris
We're moving our production 3510FC to development, so we need to replace the production 3510FC. The 6140 is nice, but pricey.
Here's the question: Would two 2540's (RAID 10) be 'faster' than one 3510? (RAID 10) and faster than one 6140 (RAID 10)?
One StoregeTek 6140 (16x72GB 15k rpm fc-al... (12 Replies)
Discussion started by: buddhavelvet
12 Replies
3. Filesystems, Disks and Memory
Hi,
We have 12x1TB SATA disks in our array and I need to create 10TB volume. I defined new storage profile on array and when I tried to add volume, I faced with ~2TB limit for new volumes. I didn't find how to set another limit on my storage profile. Is there is a way to configure one large... (3 Replies)
Discussion started by: Sapfeer
3 Replies
4. Solaris
Hi,
I have a simple question on how to correctly disable the matrix?
Looking for the Common Array Manager and I do not see this option...
Thank for help (3 Replies)
Discussion started by: bieszczaders
3 Replies
5. Solaris
Hi peeps,
Was wondering if anyone can help me, got a couple of storagetek 2540's that I need to configure. Trouble is I think they were brought as second user as all that came with them was cables.
Does anyone know how to configure them (i.e. create raid sets and map to Luns and present... (1 Reply)
Discussion started by: callmebob
1 Replies
6. Hardware
Hello all !
I am a beginner about system and networking , and after some research on internet , i didn't find any relevant information , so i post here , if someone have an experience with this kind of material or if some documentation about how to connect my storage device on my server.
I... (2 Replies)
Discussion started by: acorradi
2 Replies
7. Hardware
Hi all,
My Sun StorageTek 2540 have redundant batteries, but a battery was failed.
# /opt/SUNWstkcam/bin/sscs list -d MyStorage1 fru
Name FRU Alarm State Status Revision Unique Id
-------------------------- ----------- --------... (2 Replies)
Discussion started by: buyantugs
2 Replies
8. Solaris
Bought a Sun StorageTek 2540 SAN array a few years ago from a company that was going out of business. When we first set it up, we were able to get all the software (Common Array Manager) and firmware directly from Sun.
We just upgraded the drives, but the array is too large for the firmware. Now... (6 Replies)
Discussion started by: edison303
6 Replies
9. Solaris
Hi Guys,
I have situation here ...
server M4000 server lost connectivity to storagetek 2540
, storagetek 2540 unable to be ping.From DAS URL the storage is undetected.
Any idea why this is happening. Please share.
Thank you.
Raj (1 Reply)
Discussion started by: muralirajah
1 Replies
LEARN ABOUT DEBIAN
ocf_pacemaker_ping
OCF_PACEMAKER_PING(7) Pacemaker Configuration OCF_PACEMAKER_PING(7)
NAME
ocf_pacemaker_ping - node connectivity
SYNOPSIS
[OCF_RESKEY_pidfile=string] [OCF_RESKEY_dampen=integer] [OCF_RESKEY_name=string] [OCF_RESKEY_multiplier=integer]
[OCF_RESKEY_host_list=string] [OCF_RESKEY_attempts=integer] [OCF_RESKEY_timeout=integer] [OCF_RESKEY_options=string]
[OCF_RESKEY_debug=string]
ping [start | stop | reload | monitor | meta-data | validate-all]
DESCRIPTION
Every time the monitor action is run, this resource agent records (in the CIB) the current number of ping nodes the host can connect to. It
is essentially the same as pingd except that it uses the system ping tool to obtain the results.
SUPPORTED PARAMETERS
OCF_RESKEY_pidfile = string [/ping-]
PID file
OCF_RESKEY_dampen = integer [5s]
Dampening interval
The time to wait (dampening) further changes occur
OCF_RESKEY_name = string [pingd]
Attribute name
The name of the attributes to set. This is the name to be used in the constraints.
OCF_RESKEY_multiplier = integer []
Value multiplier
The number by which to multiply the number of connected ping nodes by
OCF_RESKEY_host_list = string []
Host list
The list of ping nodes to count.
OCF_RESKEY_attempts = integer [2]
no. of ping attempts
Number of ping attempts, per host, before declaring it dead
OCF_RESKEY_timeout = integer [2]
ping timeout in seconds
How long, in seconds, to wait before declaring a ping lost
OCF_RESKEY_options = string []
Extra Options
A catch all for any other options that need to be passed to ping.
OCF_RESKEY_debug = string [false]
Verbose logging
Enables to use default attrd_updater verbose logging on every call.
AUTHOR
Andrew Beekhof <andrew@beekhof.net>
Author.
Pacemaker Configuration 04/17/2012 OCF_PACEMAKER_PING(7)