type this cmd on ALOM
type set /HOST/bootmode script="setenv auto-boot? false"

this stop automatically goto ok prompt
 

7 More Discussions You Might Find Interesting

1. Solaris

Sun ultra enterprise 450 server does not power on

Hi, I have a sun ultra enterprise 450 server. There is no power supply to the peripheral components. Can anyone suggest what might be the problem with the server? What do i have to check for? I am new to the solaris and server world. Please suggest in detail. :) Thanks, Ashwini (5 Replies)
Discussion started by: tgashwini
5 Replies

2. UNIX for Dummies Questions & Answers

Sun ultra enterprise 450 power issue

I've search the forum and came up with someone having the same issue where the power does not going to the main board. I turn the key and nothing, no lights or anything moving. I have another board put it in the same system and it works just fine. Please help, thank you in advance. (2 Replies)
Discussion started by: vhtran
2 Replies

3. Solaris

Adding new hard drives on Sun SPARC T5440 server with Solaris 10

I need to add two new hard drives of 300 GB capacity to a SunSPARC T5440 server. The server currently has two hard drives of 146 GB each. How do I add the new drives to the existing UFS? What are the procedures involved in setting this server with the new hard drives? I am very new to Solaris... (6 Replies)
Discussion started by: ramatnmcc
6 Replies

4. Solaris

Application running too slow on Sun SPARC T5440 but run normal on sun M3000

Hi all, I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly. Here is my server T5440 info: ... (6 Replies)
Discussion started by: insatiable1610
6 Replies

5. Solaris

Unplug power from Sparc Server T5440 when in OpenBoot

show /HOST command shows that status = OpenBoot Running when in this state, can the power be unplugged from the server ? we are unable to bring the status to "powered off". Even if we issue "stop /SYS" it will momentarily be in the powered off status and then go back to power on... (1 Reply)
Discussion started by: paulk93
1 Replies

6. Solaris

Test program running taking much more time on high end server T5440 than low end server T5220

Hi all, I have written the following program and run on both T5440 and T5220 on same OS version. I found that T5540 server takes more time than T5220. Please find below the details. test1.cpp #include <iostream> #include <pthread.h> using namespace std; #define NUM_OF_THREADS 20... (17 Replies)
Discussion started by: sanjay_singh85
17 Replies

7. UNIX for Beginners Questions & Answers

Start /SYS on SUN SPARC does not start machine [SUN SPARC ENTERPRISE T-5240]

-> start /SYS Are you sure you want to start /SYS (y/n)? y Starting /SYS ]-> show HOST /HOST Targets: bootmode diag domain Properties: autorestart = reset autorunonerror = false bootfailrecovery = poweroff ... (29 Replies)
Discussion started by: z_haseeb
29 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_alom - Fence agent for Sun ALOM DESCRIPTION
fence_alom is an I/O Fencing agent which can be used with ALOM connected machines. fence_alom accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_alom can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. Vendor URL: http://www.sun.com PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -x, --ssh SSH connection (Default Value: true) -k, --identity-file=<filename> Identity file for ssh -4, --inet4-only Forces agent to use IPv4 addresses only -6, --inet6-only Forces agent to use IPv6 addresses only -u, --ipport=<port> TCP port to use for connection with device -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 5) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 0) --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password secure SSH connection (Default Value: true) identity_file Identity file for ssh inet4_only Forces agent to use IPv4 addresses only inet6_only Forces agent to use IPv6 addresses only ipport TCP port to use for connection with device verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 5) power_wait Wait X seconds after issuing ON/OFF (Default Value: 0) delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_alom (Fence Agent) 2009-10-20 FENCE_AGENT(8)