Sponsored Content
Operating Systems AIX Live Partition Mobility using HP XP SAN storage Post 302669493 by johnf on Wednesday 11th of July 2012 03:53:22 AM
Old 07-11-2012
Live Partition Mobility using HP XP SAN storage

I have a real problem that I hope someone has experience of. I am setting up an LPM for a client who use HP SAN storage. In the past when I setup an LPM system the second World Wide Name (WWN) for the virtual client adapters were given to the storage team who then zoned and mapped these to same LUNs as the first WWN, simple. However with this client the storage team reckon there is no way they can do this! This is because the only way to zone and map is to see the WWN on the GUI tool and attach that using the same GUI to the LUN! As the second WWN is always invisible until LPM is started I cannot "illuminate it" for the GUI to see.

The HP SAN storage model is XP24000.

I sincerely hope someone out there has experience of this problem.
 

9 More Discussions You Might Find Interesting

1. Filesystems, Disks and Memory

Switching SAN storage

Hi, I have an existing SUN server that has a SAN storage installed on it. It also has softwares like Appwrox(scheduler), Taradata (database client), Samba Share and a few more installed on it. Now suppose that I have a new unix server server and i switch the same SAN store from the old unix... (1 Reply)
Discussion started by: myloginid
1 Replies

2. AIX

SAN storage and speed

I have 3 SAN disks of 1 TB each. Is it more efficient to make 1 large Volume group with multiple LV's or 3 Volume Groups with 1 LV each. The SAN disk is where all my backups will be dumped.:confused: (1 Reply)
Discussion started by: daveisme
1 Replies

3. Solaris

SAN Storage to solaris 10 server

Hi, I have configured our SAN Storage to be connected to our new SUN T5220. On the SAn it looks all fine on the server I do not see any connection: cfgadm -al Ap_Id Type Receptacle Occupant Condition c1 scsi-bus connected ... (4 Replies)
Discussion started by: manni2
4 Replies

4. Red Hat

how do we check SAN storage?

Hello, I am using LINUX OS. I want to check what is the SAN storage size. How do i check this in server? Any help is really appreciated.. (3 Replies)
Discussion started by: govindts
3 Replies

5. Solaris

Cannot see the IBM SAN storage

HI all, I had recently change the Server storage from EMC to the IBM SAN. but after the configuration, the IBM success to see the server HBA port and successfully assign a LUN for the server. When i go to the server, and restarted it. i use the "format" command to check, but din see any... (1 Reply)
Discussion started by: SmartAntz
1 Replies

6. UNIX for Dummies Questions & Answers

Storage from SAN

hi guys I installed Centos 5.5 (local disk). I am using 2 HBAs Now I mapped 5 LUNs from a Storage. I will be using LVM just to test I assigned a LUN I've read I have to use multipath to avoid my Centos see the LUN twice I enabled mdmpd and multipathd... something else I should do? ... (8 Replies)
Discussion started by: kopper
8 Replies

7. Solaris

SAN Storage for ASM

Hi, We are planning to setup a 10gR2 RAC and storage on ASM. We use Sun StorEdge SAN. The installation and configuration manual says to configure ASM diskgroups with raw devices (preferably raw disk not volumes). I dont really know if its possible to present raw disks to the Solaris... (4 Replies)
Discussion started by: esmgr
4 Replies

8. AIX

New to San Storage

Can anyone recommend a good book on san storage basics and how it communicates with an AIX server? (1 Reply)
Discussion started by: NycUnxer
1 Replies

9. AIX

Live Partition Mobility

Hello All, I recently did LPM at one of my client site, and thought of sharing it with the forum. I hope you find it helpful. (2 Replies)
Discussion started by: ibmtech
2 Replies
st_san_safe(5)							     OBSOLETED							    st_san_safe(5)

NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED) VALUES
Failsafe Default Allowed values Recommended values or DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3. This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with a status of The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from HP-UX systems via standard tape commands like which would corrupt a backup in process. Who Is Expected to Change This Tunable? Anyone. Restrictions on Changing Changes to this tunable take effect immediately. When Should the Tunable Be Turned On? This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration. What Are the Side Effects of Turning the Tunable On? The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This behavior prevents the usage of any tape device special file without the no-rewind-on-close option. When Should the Tunable Be Turned Off? This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not function unless it has access to device special files without the no-rewind-on-close option. What Are the Side Effects of Turning the Tunable Off? A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN. What Other Tunables Should Be Changed at the Same Time? None. WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of HP-UX. Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation, some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun- able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was factory installed on your system, see at AUTHOR
was developed by Hewlett-Packard. SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7). Tunable Kernel Parameters st_san_safe(5)
All times are GMT -4. The time now is 08:53 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy