In my vio server I have the below output
In my vio client lpar I have the below output
So it is clear that the cd device has been served to the lpar by the vio server. My question is why there are 2 cd devices showing up in available state?
I have a standard template I deploy for each of my AIX servers. It's in a mksysb format which I pulled via the nim server after I originally set it up.
I'm trying to restore this mksysb over the wire to a remote system. The remote system is an lpar running under vio (no HMC attached). The disk... (1 Reply)
Can you have a Dynamic LPAR without VIO and if yes is there a benefit to having both? I am attempting to implement VIO and Resource pooling at my company and want to understand the limitations.
Also, I have been told the managing and allocation of the Logical Volumes is a time consuming task as... (0 Replies)
We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Hi,
I want to know wheather partition size for installation of vio client can be specified on vio server
example
If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR.
How can I do it without rebooting the LPARS.
POWER6 with HMC
LPARS = AIX 6.1
Any info
developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ...
But... (5 Replies)
I am wondering if there is a command I can run from **with-in** LPAR server (server01) to find out the hostname or IP address or other parameters for VIO server in charge of server01? (1 Reply)
Just a question which may seem dumb to some out there, but then again I am not a super technie so that's my excuse.
Is it possible to say provision a test AIX LPAR (has a 10gb boot lun and 20gb data) under a VIO which has connectivity to SAN Array A so it can see the disks provisioned to it,... (2 Replies)
Hi All,
I've been trying to create a new LPAR for some days now but I can't get the VIO server to recognize the new LPAR. This is what I did:
On HMC create new LPAR
On HMC create new virtual scsi adapter for LPAR in VIO profile
On HMC add new virtual scsi adapter for LPAR with DLPAR... (6 Replies)
:wall::wall::wall:
1. I have created an LPAR in the HMC.
2. I have allocated the storage from an Hitachi AMS2500 and assigned it to the host group.
3. I have zoned the LPAR and Storage on a Brocade 5100. (The zone sees the AMS)
Next I activated the LPAR in the HMC, SMS mode for the mksysb... (3 Replies)
Discussion started by: Dallasguy7
3 Replies
LEARN ABOUT SUNOS
ppmtosixel
ppmtosixel(1) General Commands Manual ppmtosixel(1)NAME
ppmtosixel - convert a portable pixmap into DEC sixel format
SYNOPSIS
ppmtosixel [-raw] [-margin] [ppmfile]
DESCRIPTION
Reads a portable pixmap as input. Produces sixel commands (SIX) as output. The output is formatted for color printing, e.g. for a DEC
LJ250 color inkjet printer.
If RGB values from the PPM file do not have maxval=100, the RGB values are rescaled. A printer control header and a color assignment table
begin the SIX file. Image data is written in a compressed format by default. A printer control footer ends the image file.
OPTIONS -raw If specified, each pixel will be explicitly described in the image file. If -raw is not specified, output will default to com-
pressed format in which identical adjacent pixels are replaced by "repeat pixel" commands. A raw file is often an order of magni-
tude larger than a compressed file and prints much slower.
-margin
If -margin is not specified, the image will be start at the left margin (of the window, paper, or whatever). If -margin is speci-
fied, a 1.5 inch left margin will offset the image.
PRINTING
Generally, sixel files must reach the printer unfiltered. Use the lpr -x option or cat filename > /dev/tty0?.
BUGS
Upon rescaling, truncation of the least significant bits of RGB values may result in poor color conversion. If the original PPM maxval was
greater than 100, rescaling also reduces the image depth. While the actual RGB values from the ppm file are more or less retained, the
color palette of the LJ250 may not match the colors on your screen. This seems to be a printer limitation.
SEE ALSO ppm(5)AUTHOR
Copyright (C) 1991 by Rick Vinci.
26 April 1991 ppmtosixel(1)