Sponsored Content
Operating Systems HP-UX FAULTY DISK replacement HP rx4640 Post 302644183 by gjk on Monday 21st of May 2012 11:54:15 AM
Old 05-21-2012
Thank you for your help VBE and you are not blind but I don't know the OS version. As i have very limited access to the costumer site only tonight i will be able to find out the OS version and more about the disk. What i have confirmed is that it is a boot disk. With what i know from costumer the system is connected to msl6030 tape library and they do backups of configuration every day. Unfortunately I'm not familiar with diagnose tool but I'll try my best to get as much info as possible and post.
Thank you very very much
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
vxsplitlines(1M)														  vxsplitlines(1M)

NAME
vxsplitlines - show disks with conflicting configuration copies in a cluster SYNOPSIS
vxsplitlines [-g diskgroup] [-c daname] DESCRIPTION
If you import portions of a disk group on different systems, this can lead to conflicting configuration copies on the disks of the disk group. If the configuration information in a disk group is ambiguous, it may not be possible for Veritas Volume Manager to determine which config- uration copy is most up-to-date. (This is usually termed a serial split brain (SSB) condition when it occurs in a cluster.) You cannot import a disk group in this state unless you specify which disk's configuration copy to use. You can use the vxsplitlines command to see which disks in a disk group have conflicting configuration copies, and use this information together with your knowledge of the history of the disk groups' usage to determine which configuration copy is most valid. The output from vxsplitlines displays the vxdg commands that you can run to import the disk group using the available configuration copies. The -o selectcp option of the vxdg import command is used to select the configuration copy to use for the import. OPTIONS
-c daname Display the SSB IDs for each disk that are stored in the configuration copy on the disk specified by its disk access name. Note: Although the SSB IDs for some disks may match, this does not necessarily mean that those disks' configuration copies have recorded all the configuration changes. When viewed from some other configuration copies, the SSB IDs of the same disks may not match. -g diskgroup Specifies the disk group. If a disk group is not specified, the default disk group is used as determined from the rules on the vxdg(1M) manual page. EXAMPLES
Display the disks on each side of the split in the disk group newdg: vxsplitlines -g newdg Display the SSB IDs stored in the configuration copy on disk c2t4d0: vxsplitlines -g newdg -c c2t4d0 NOTES
The vxsplitlines is primarily intended to be used with private disk groups, but it also works with shared disk groups. The version number of the disk group must be 110 or greater. SEE ALSO
vxdg(1M) Veritas Volume Manager Administrator's Guide VxVM 5.0.31.1 24 Mar 2008 vxsplitlines(1M)
All times are GMT -4. The time now is 05:49 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy