Sponsored Content
Operating Systems HP-UX FAULTY DISK replacement HP rx4640 Post 302644051 by vbe on Monday 21st of May 2012 08:28:56 AM
Old 05-21-2012
I dont know if I can help because I have VERY little experience on RX boxes now I managed to find one for home someone removed the disks before I got hold of it...
You did not say (or Im blind...) your OS version!
vg00 is usually the OS (and so root / boot disks...) even more true when you see no lvol2... for its the swap...
I would suggest before going further to get 2 new disks, get them ordered you may not need them or perhaps one but if things go wrong or the situation is not cool you may be glad to have 2 with you (believe my experience...).
Next once you have them try to make a recovery tape or an "Golden Image" somehow, if the system manages then you are perhaps in the way to solve your issue online, if not try to find the last bootable backup of the system (you may need it...)
Lest say you managed a make_recovery, you know can go and try stm or xstm (X GUI ) and see what the tool diagnose about your disks

here give us what you found, and we will do a bit of brainstorming...

Good luck!
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
vxbootsetup(1M) 														   vxbootsetup(1M)

NAME
vxbootsetup - set up system boot information on a Veritas Volume Manager disk SYNOPSIS
/etc/vx/bin/vxbootsetup [-g diskgroup] [medianame ... ] DESCRIPTION
The vxbootsetup utility configures physical disks so that they can be used to boot the system. Before vxbootsetup is called to configure a disk, the required volumes, standvol, rootvol and swapvol (and optionally, dumpvol) must be created on the disk. All of these volumes must be contiguous with only one subdisk. The -g option may be used to specify the boot disk group. If no medianame arguments are specified, all disks that contain usable mirrors of the root, swap, /usr and /var volumes are configured to be bootable. If medianame arguments are given, only the disks that are associated with the specified disk names are configured to be bootable. vxbootsetup requires that: o The root volume must be named rootvol and must have a usage type of root. o The swap volume must be named swapvol and must have a usage type of swap. o The volumes containing /usr and /var (if any) must be named usr and var, respectively. See the chapter "Recovery from Boot Disk Failure" in the Veritas Volume Manager Troubleshooting Guide for detailed information on how the system boots and how VxVM impacts the system boot process. The vxmirror, vxrootmir, and vxresize utilities call vxbootsetup automatically. If you use vxassist, or vxmake and vxplex to create mirrors of the root volume on a disk, you must run vxbootsetup explicitly to make the disk bootable. ARGUMENTS
medianame Specifies the disk name (disk media name) of a VM disk that is to be configured as bootable. SEE ALSO
disksetup(1M), edvtoc(1M), vxassist(1M), vxevac(1M), vxinstall(1M), vxintro(1M), vxmake(1M), vxmirror(1M), vxplex(1M), vxresize(1M), vxrootmir(1M) Veritas Volume Manager Troubleshooting Guide VxVM 5.0.31.1 24 Mar 2008 vxbootsetup(1M)
All times are GMT -4. The time now is 07:32 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy