I dont know if I can help because I have VERY little experience on RX boxes now I managed to find one for home someone removed the disks before I got hold of it...
You did not say (or Im blind...) your OS version!
vg00 is usually the OS (and so root / boot disks...) even more true when you see no lvol2... for its the swap...
I would suggest before going further to get 2 new disks, get them ordered you may not need them or perhaps one but if things go wrong or the situation is not cool you may be glad to have 2 with you (believe my experience...).
Next once you have them try to make a recovery tape or an "Golden Image" somehow, if the system manages then you are perhaps in the way to solve your issue online, if not try to find the last bootable backup of the system (you may need it...)
Lest say you managed a make_recovery, you know can go and try stm or xstm (X GUI ) and see what the tool diagnose about your disks

here give us what you found, and we will do a bit of brainstorming...

Good luck!
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
SCSI(4) 						     Kernel Interfaces Manual							   SCSI(4)

Name
       SCSI - Small Computer System Interconnect

Description
       The  ULTRIX  system interfaces to disk and tape devices through the Small Computer System Interconnect (SCSI).  Initial ULTRIX SCSI support
       is limited to the Digital-supplied mass storage devices.  The following devices are fully supported on the ULTRIX system:

       o    Winchester disks: RZ22, RZ23, RZ23L, RZ24, RZ55, RZ56, RZ57, RX23, RX26, RX33

       o    Magnetic tapes: TZ30, TZK50, TLZ04, TSZ05, TKZ08, TZK10

       o    Optical disks: RRD40, RRD42

       Under the ULTRIX operating system, a SCSI device is referred to by its logical name.  Logical names take the following form:
       nn#
       The nn argument is the two-character name; the number sign (#) represents the unit number.  The two character names for SCSI devices are:

       rz  -  RZ22, RZ23, RZ23L, RZ24, RZ55, RZ56, RZ57, RX23, RX26, RX33, RRD40, RRD42 disks

       tz  -  TZ30, TZK50, TLZ04, TSZ05, TKZ08, and TZK10 tapes

       The unit number is a combination of the SCSI bus number, either 0, 1, ... and the device's target ID number.   The  unit  number  is  eight
       times  the  bus	number plus the target ID.  For example, an RZ23 disk at target ID 3 on bus 0 would be referred to as rz3; a TZK50 tape at
       target ID 5 on the second SCSI bus would be referred to as 13.

       The SCSI bus has eight possible target device IDs.  By default, one is allocated to the system.	This allows for a maximum of seven  target
       devices connected to a SCSI bus.

Restrictions
       The ULTRIX SCSI device driver does not operate with optical disks, other than the Digital-supplied devices.

       The SCSI driver attempts to support on a best effort basis, non-Digital-supplied winchester disks and magnetic tapes.

       The following notes apply to the driver's handling of non-Digital-supplied disks:

	  o   These disks are assigned a device type of RZxx, instead of RZ22, RZ23, RZ23L, RZ55, RZ56, RZ57, RX23, RX26, or RX33.  The RZxx disks
	      follow the same logical device naming scheme as the Digital-supplied disks.

	  o   During the autoconfigure phase of the system startup, the driver prints the contents of the SCSI vendor  ID,  product  ID,  and  the
	      revision level fields of the inquiry data return by the SCSI device.

	  o   RZxx  disks  are	assigned a default partition table. The default table can be modified by editing the sz_rzxx_sizes[8] entry in the
	      file The utility can also be used to modify the partition table on a RZxx disk.

	  o   The only logical unit number (LUN) supported for each target ID is 0.