Sponsored Content
Operating Systems HP-UX FAULTY DISK replacement HP rx4640 Post 302643801 by Scrutinizer on Sunday 20th of May 2012 04:56:44 PM
Old 05-20-2012
I would not touch this if I were you. Ask an experienced HP-UX admin in your company to have a look...
 

10 More Discussions You Might Find Interesting

1. Solaris

Disk replacement with svm

I dont even know what raid level this is, but its raid 5 mirrored from the looks of it. I have a failed disk (t12) within this mirror. What is the best way to replace this disk? 2 things concern me, isn't there a command to prepare the disk for a hot swap? and what should i do with the... (3 Replies)
Discussion started by: BG_JrAdmin
3 Replies

2. AIX

Removing Faulty Disk SSA

Hi Experts, I have configured A D40 Array. There is an faulty disk which is not part of an raid volume but shows fault in the diagnostics. pdisk15 U0.1-P1-I1/Q1-W40AA83CC2400D SSA160 Physical Disk Drive ( MB) Is there a way to stop this... (2 Replies)
Discussion started by: vuppala360
2 Replies

3. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

4. HP-UX

Remove Faulty disk from HP-UX LVM VG

Requirement to remove a faulty mirrored disk from hp-ux LVM <root@pdwp1s>/etc # vgdisplay -v /dev/vg00 vgdisplay: Warning: couldn't query physical volume "/dev/dsk/c2t0d0": The specified path does not correspond to physical volume attached to this volume group vgdisplay: Warning: couldn't... (9 Replies)
Discussion started by: Shirishlnx
9 Replies

5. HP-UX

Remove faulty disk LV from VG

Hi, Have mirrored the primary disk to 3 . Server and OS: # uname -a HP-UX pdwp1s B.11.11 U 9000/800 118434630 unlimited-user license # model 9000/800/L3000-7x # strings /etc/lvmtab /dev/vg00 +F@< /dev/dsk/c1t2d0 /dev/dsk/c2t2d0 /dev/dsk/c2t0d0 But now I have only 1 disk... (5 Replies)
Discussion started by: Shirishlnx
5 Replies

6. Solaris

[solved] How to blink faulty disk in Solaris hardware?

Hi Guys, One of two disks in my solaris machine has failed, the name is disk0, this is SUN physical sparc machine But I work remotely, so people working near that physical server are not that technical, so from OS command prompt can run some command to bink faulty disk at front panel of Server.... (9 Replies)
Discussion started by: manalisharmabe
9 Replies

7. AIX

Disk replacement on SharedVG.

Hi, One of my disk is in 'disk missing state'. It is a sharedVG and cluster nodes. The errpt keeps reporting stale partition error. lvs are in open/stale state. In this sceanario is replacing the disk the best practice? When i do a lsdev the disk is labelled as below. hdisk3 Available ... (2 Replies)
Discussion started by: ElizabethPJ
2 Replies

8. Filesystems, Disks and Memory

DISK ARRAY PROTECTION SUSPENDED message displayed following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (1 Reply)
Discussion started by: terrya
1 Replies

9. AIX

DISK ARRAY PROTECTION SUSPENDED message following disk replacement

Hello, On 4/20/2018, we performed a disk replacement on our IBM 8202 P7 server. After the disk was rebuilt, the SAS Disk Array sissas0 showed a status of degraded. However, the pdisks in the array all show a status of active. We did see a message in errpt. DISK ARRAY PROTECTION SUSPENDED. ... (3 Replies)
Discussion started by: terrya
3 Replies

10. UNIX for Beginners Questions & Answers

Show faulty shows PS1 faulty

I plugged both power cables in both power supply. When I unplugged each power cable one by one, the SPARC T4-1 machine keep running. However, show faulty command shows below message. (I have also attached the picture of both power supply) -> show faulty Target ... (1 Reply)
Discussion started by: z_haseeb
1 Replies
mwrite(1)						      General Commands Manual							 mwrite(1)

NAME
mwrite - mtools utility to perform a low level write (copy) of a UNIX file to DOS SYNOPSIS
mwrite [-mntv] unixfile msdosfile mwrite [-mntv] unixfile [unixfiles...] [msdosdirectory] OPTIONS
Preserves the file modification time. Specifies that a warning is not issued when an existing file is specified as the target file. If this option is not specified, the mwrite command verifies whether or not to overwrite an existing file. Specifies a text file transfer. Line terminators are converted to the appropriate format. Specifies verbose mode. Displays the new file name if the UNIX file name requires conversion. DESCRIPTION
The mwrite command copies the specified UNIX file to the named DOS file, or copies multiple UNIX files to the named DOS directory. The destination directory cannot be omitted. Reasonable care is taken to create a valid DOS file name. If an invalid name is specified, the mwrite command changes the name, then displays the new name if the -v option is specified. DOS subdirectory names that contain the '/' or '' separator are supported. If you use the '' separator or wildcards, you must enclose file names in quotes to protect them from the shell. The mcd command can be used to establish the device and the current working directory (relative to DOS), otherwise the default is A:. Not all UNIX file names are supported in the DOS world. The mwrite command may have to change UNIX names to fit the DOS file name conven- tions. The following table shows some examples of file name conversions: ----------------------------------------------- UNIX name DOS name Reason for the change ----------------------------------------------- thisisatest THISISAT file name too long file.stuff FILE.STU extension too long prn.txt XRN.TXT PRN is a device name .abc X.ABC null file name hot+cold HOTXCOLD illegal character ----------------------------------------------- EXIT STATUS
The following exit values are returned: Success. Failure. ENVIRONMENT VARIABLES
The following environment variables affect the execution of mwrite: If set, this variable names the file that contains the name of the cur- rent mtools working directory as established by the mcd command. If this variable is not set, the file $HOME/.mcwd is used. FILES
Contains the name of the current mtools working directory as established by the mcd command. If this file does not exist, the default mtools working directory is A:. Executable file SEE ALSO
Commands: dos2unix(1) mcd(1), mcopy(1), mdiskcopy(1), mkmanifest(1), mread(1), mtools(1), unix2dos(1) mwrite(1)
All times are GMT -4. The time now is 01:02 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.