Sponsored Content
Operating Systems Solaris Hardware to software RAID migration Post 302626269 by rock123 on Thursday 19th of April 2012 06:08:40 AM
Old 04-19-2012
Hardware to software RAID migration

We have hardware RAID configured on our T6320 server and two LDOMs are running on this server. One of our disk got failed and replaced. After replacemnt the newly installed disk not detected by RAID controlled so Oracle suggested to upgrade the REM firmware. As this is the standalone production server, we do not want to take risk on REM upgrade. So we are planning for migrating the h/w RAID to software RAID. Kindly suggest how to perform this migration without disturbing LDOMs running on this server.

root@hostname# raidctl -l
Controller: 0
Volume:c0t0d0
Volume:c0t2d0
Disk: 0.3.0
Disk: 0.6.0
Disk: 0.7.0

root@hostname# format
Searching for disks...done


AVAILABLE DISK SELECTIONS:
0. c0t0d0 <LSILOGIC-LogicalVolume-3000 cyl 65533 alt 2 hd 16 sec 273>
/pci@0/pci@0/pci@2/LSILogic,sas@0/sd@0,0
1. c0t2d0 <LSILOGIC-LogicalVolume-3000 cyl 65533 alt 2 hd 16 sec 273>
/pci@0/pci@0/pci@2/LSILogic,sas@0/sd@2,0
2. c5t600A0B80003391A40000047E49C1B118d0 <SUN-CSM200_R-0710 cyl 34989 alt 2 hd 64 sec 64>
/scsi_vhci/ssd@g600a0b80003391a40000047e49c1b118
3. c5t600A0B80003391A40000146A4D958AAAd0 <SUN-CSM200_R-0715 cyl 48638 alt 2 hd 128 sec 64>
/scsi_vhci/ssd@g600a0b80003391a40000146a4d958aaa
4. c5t600A0B800033935C000004BD49A4FC4Fd0 <SUN-CSM200_R-0710 cyl 41598 alt 2 hd 256 sec 64>
/scsi_vhci/ssd@g600a0b800033935c000004bd49a4fc4f
5. c5t600A0B800033935C000004FF49AB3881d0 <SUN-CSM200_R-0710 cyl 2558 alt 2 hd 64 sec 64>
/scsi_vhci/ssd@g600a0b800033935c000004ff49ab3881
6. c5t600A0B800033935C0000205F4E80D62Ed0 <SUN-CSM200_R-0715 cyl 51198 alt 2 hd 64 sec 64>
/scsi_vhci/ssd@g600a0b800033935c0000205f4e80d62e
7. c5t600A0B800033935C000015914D8194C6d0 <SUN-CSM200_R-0715 cyl 10238 alt 2 hd 64 sec 64>
/scsi_vhci/ssd@g600a0b800033935c000015914d8194c6
8. c5t5000C5003AE7DCBFd0 <LSILOGIC-LogicalVolume-3000 cyl 65533 alt 2 hd 16 sec 273>
/scsi_vhci/disk@g5000c5003ae7dcbf


# df -h /vdisk*
Filesystem size used avail capacity Mounted on
/dev/dsk/c0t2d0s0 69G 68G 160M 100% /vdisk2
/dev/dsk/c0t0d0s3 69G 68G 160M 100% /vdisk1
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

how to hardware RAID 1 on T5120

Hi, I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1" The System did come preinstalled as it comes from sun. I did not do much on it. I booted system using boot cdrom -s gave format... (6 Replies)
Discussion started by: upengan78
6 Replies

3. Solaris

T2000 Hardware RAID

Hi, I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds. I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this? AVAILABLE DISK SELECTIONS: 0.... (12 Replies)
Discussion started by: honmin
12 Replies

4. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

5. Solaris

Hardware Raid - LiveUpgrade

Hi, I have a question. Do LiveUpgrade supports hardware raid? How to choose the configuration of the system disk for Solaris 10 SPARC? 1st Hardware RAID-1 and UFS 2nd Hardware RAID-1 and ZFS 3rd SVM - UFS and RAID1 4th Software RAID-1 and ZFS I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies

6. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

7. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies

8. Solaris

Hardware raid patching

Dear All , we have hardware raid 1 implemented on Solaris Disks. We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers. Thanks... Rj (7 Replies)
Discussion started by: jegaraman
7 Replies

9. Solaris

Hardware RAID using three disks

Dear All , Pl find the below command , # raidctl -l Controller: 1 Volume:c1t0d0 Disk: 0.0.0 Disk: 0.1.0 Disk: 0.3.0 # raidctl -l c1t0d0 Volume Size Stripe Status Cache RAID Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
scsi_vhci(7D)							      Devices							     scsi_vhci(7D)

NAME
scsi_vhci - SCSI virtual host controller interconnect driver DESCRIPTION
The scsi_vhci driver is a SCSA compliant pseudo nexus driver that supports Solaris operating system I/O multipathing services for SCSI-3 devices. This driver introduces a fundamental restructuring of the Solaris device tree to enable a multipath device to be represented as single device instance rather than as an instance per physical path as in earlier Solaris versions. The multipath SCSI target devices managed by this driver are identified and represented by using SCSI-3 VPD page(0x83) as the device's unit address. Symbolic links in /dev/[r]dsk continue to adhere to the cNtNdNsN format. cN is the logical controller number assigned to this driver instance. tN is the global unique identifier (GUID) of the multipath target device (64/128 bits), represented as hexadecimal numbers. The following is an example of a system with a A5000 storage array: ... /dev/rdsk/c4t200000203709C3F5d0s0 -> ../../devices/scsi_vhci/ ssd@g200000203709c3f5:a,raw ... /dev/rdsk/c4t200000203709C3F5d0s7 -> ../../devices/scsi_vhci/ ssd@g200000203709c3f5:h,ra ... The following is an example of a system with a T300 storage array: ... /dev/rdsk/c1t60020F200000033939C2C2B60008D4AEd0s0 -> ../../devices/ scsi_vhci/ssd@g60020f200000033939a2c2b60008d4ae:a,raw ... /dev/rdsk/c1t60020F200000033939A2C2B60008D4AEd0s7 -> ../../devices/ scsi_vhci/ssd@g60020f200000033939a2c2b60008d4ae:h,raw The scsi_vhci driver receives naming and transport services from one or more physical HBA (host bus adapter) devices. To support multi- pathing, a physical HBA driver must comply with the multipathing services provided by this driver. The scsi_vhci driver supports the standard functions provided by the SCSA interface. Configuration The scsi_vhci driver can be configured by defining properties in the scsi_vhci.conf file. The scsi_vhci driver supports the following property: device-type-scsi-options-list To add a third-party (non-Sun) symmetric storage device to run under scsi_vhci (and thereby take advantage of Solaris I/O multipathing), you add the vendor ID and product ID for the device, as those strings are returned by the SCSI Inquiry command. As shipped, the scsi_vhci.conf file contains, in part: # device-type-scsi-options-list = # "SUN SENA", "symmetric-option"; # symmetric-option=0x1000000; For example,to add a device from a vendor with the ID of "Acme" and a product ID of "MSU", you would add: device-type-scsi-options-list = "Acme MSU", "symmetric-option"; symmetric-option=0x1000000; In addition to "Acme," you also might want to add another entry, for example, a device from "XYZ" vendor with a product ID of "ABC:" device-type-scsi-options-list = "Acme MSU", "symmetric-option", "XYZ ABC", "symmetric-option"; symmetric-option=0x1000000; FILES
/kernel/drv/sparcv9/scsi_vhci 64-bit kernel module (SPARC). /kernel/drv/scsi_vhci 32-bit kernel module (x86). /kernel/drv/scsi_vhci.conf Driver configuration file. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Architecture |PCI-based systems | +-----------------------------+-----------------------------+ |Availability |SUNWckr | +-----------------------------+-----------------------------+ SEE ALSO
eeprom(1M), prtconf(1M), attributes(5), fcp(7D), fctl(7D), fp(7D), ssd(7D), scsi_abort(9F), scsi_ifgetcap(9F), scsi_pkt(9S), scsi_reset(9F), scsi_transport(9F), scsi_inquiry(9S), scsi_extended_sense(9S) Writing Device Drivers Small Computer System Interface-3 (SCSI-3) NOTES
In previous releases, the scsi_vhci.conf file supported the mpxio-disable property, which allowed you to disable Solaris I/O multipathing on a system-wide basis. This property is not present in the current release of the Solaris operating system. Multipathing is always enabled in scsi_vhci. If you want to disable multipathing, use the mechanisms provided by the HBA drivers. See fp(7D). In previous releases, Solaris I/O multipathing was also known as MPxIO and Sun StorEdge Traffic Manager (STMS). SunOS 5.10 2 Dec 2004 scsi_vhci(7D)