04-17-2012
Thanks all for your valuable comments ...
catch u later in another query ...
Chrees
10 More Discussions You Might Find Interesting
1. Filesystems, Disks and Memory
Am trying to differentiate between the local disks and LUN's presented from SAN onto the server. Have Tried fdisk -l, however I quite cudn't differentiate the local disks from SAN presented LUN's.
Can you pls. let me know the procedure and commands to find this.
OS - RHEL 4
SAN - EMC... (3 Replies)
Discussion started by: Crazy_murli
3 Replies
2. Solaris
hi all
can anyone tell me how to track a new attached LUN in a solaris server?? (3 Replies)
Discussion started by: raynu.sharma
3 Replies
3. Red Hat
Hi,
I have a SAN LUN of 550 GB created as an ext3 partition of the entire lun and need to make the lun and partition larger... 600 GB
# fdisk -l /dev/sdj
Disk /dev/sdj: 590.5 GB, 590558003200 bytes
255 heads, 63 sectors/track, 71797 cylinders
Units = cylinders of 16065 * 512 = 8225280... (3 Replies)
Discussion started by: jamba1
3 Replies
4. Solaris
Hello to all,
Actually, currently on my Solaris box, I've a LUN (5TB space) from a EMC storage which is working fine, and a partition with ZFS filesystem is created for that LUN. as further you'll see in the logs, the "c4t6006016053802E00E6A9196B6506E211d0s2" is the current configured LUN in the... (4 Replies)
Discussion started by: Anti_Evil
4 Replies
5. Red Hat
Hi,
I am trying to setup multipathing (using DM multipath) for a redhat cluster setup ...all setup is done but issue is :
node 1 shows the shared iscsi lun as sdc
node 2 shows the same as sdg (changes on reboots)
Due to this (i guess) i get i/o error & i can not read files created by... (0 Replies)
Discussion started by: heman96
0 Replies
6. Linux
I have created a lun on Storage and connected it to server using fiber channel.
LUN is presented on new Server .
How do i check and mount this newly created LUN? (1 Reply)
Discussion started by: pinga123
1 Replies
7. UNIX for Advanced & Expert Users
Hello,
We have IBM storwize v7000 storage. I have created thin provisioned LUN and attached it to my server(dell r910, Centos 7).
Whenever I copy files in that LUN correspondingly Thin provisioned LUN's used space increases but when I remove files to free up space the LUN's size isn't... (5 Replies)
Discussion started by: Vit0_Corleone
5 Replies
8. Post Here to Contact Site Administrators and Moderators
ssssssssssss (0 Replies)
Discussion started by: sampathenjoy
0 Replies
9. Linux
Hi
I am not familiar with the linux, but I was asked to create a file system on a LUN from the NetApp that was mapped to the linux server.
The server is runing:
uname -a
Linux localhost.localdomain 2.6.18-92.el5 #1 SMP Tue Apr 29 13:16:15 EDT 2008 x86_64 x86_64 x86_64 GNU/Linux
and now... (6 Replies)
Discussion started by: fretagi
6 Replies
10. Red Hat
I have NetApp LUN that was presented to a Red Hat Enterprise Linux Server release 5.7 (Tikanga) machine.
But this LUN has already data, because it was being used on another server.
I can see the new LUN when running fdisk:
fdisk -l | egrep '^Disk' | egrep -v 'dm-' | grep -v identifier
Disk... (15 Replies)
Discussion started by: fretagi
15 Replies
format(1M) format(1M)
NAME
format - format an HP SCSI disk array LUN
SYNOPSIS
device_file
DESCRIPTION
formats one LUN of the HP SCSI disk array associated with device file, device_file. The format will usually be a soft or zeroing format,
in which the controller writes zeroes to the data area and parity area, if any, of the LUN.
NOTE: The above should always be true of a sub-LUN, but the controller might decide, based on certain conditions, to do a full format of a
regular LUN, which consists of sending a mode select and a media initialization command to the physical drive(s) in question, fol-
lowed by zeroing the data and parity area, if any. The conditions which will cause a full format to be done are as follows:
1. The controller received a Mode Select command which requires a drive sector size change.
2. The controller received a Mode Select command which changed a parameter in the Format Device Page(0x03).
3. The LUN contains one or more failed drives. In this case only a certain subset of the drives containing the failed drives
will be formatted.
4. Either the FmtData or the CmpLst bit in the Format Unit CDB is set.
RETURN VALUE
returns the following values:
0 Successful completion.
-1 Command failed.
DIAGNOSTICS AND ERRORS
Errors can originate from problems with:
o
o SCSI (device level) communications
o system calls
Error messages generated by format:
An error in command syntax has occurred.
Enter command again with all required arguments, in the order shown.
To ensure that
does not modify a disk array that is being used by another process, attempts to obtain exclusive access to the disk array. If the
disk array is already opened by another process (for example, LVM -- the Logical Volume Manager), a "" error message is returned by
the driver. To eliminate the "" condition, determine what process has the device open. In the case of LVM, it is necessary to
deactivate the volume group containing the array before formatting array LUNs (see vgchange(1M)).
The LUN number, which is derived from the device file name, is out of range.
The addressed LUN
is not configured, and thus is not known to the array controller.
Utilities must be able to open the device file for raw access.
The device being addressed is not an HP SCSI disk array.
SCSI (device level) communication errors:
Sense data associated with the failed operation is printed.
Error messages generated by system calls:
uses the following system calls:
and
Documentation for these HP-UX system calls contains information about the specific error conditions associated with each call. does not
alter the value of The interpretation of for printing purposes is performed by the system utility
EXAMPLES
To format the HP SCSI disk array LUN on a Series 800:
WARNING
The command will destroy all user data on the addressed LUN.
DEPENDENCIES
The HP C2425 and HP C2427 disk arrays are only supported on Series 700 systems running HP-UX version 9.0X.
The HP C2430 disk array is supported on Series 700 and 800 systems running HP-UX versions 9.0X and 10.0X.
AUTHOR
was developed by HP.
format(1M)