Sponsored Content
Full Discussion: Net Boot with Flash install
Operating Systems Solaris Net Boot with Flash install Post 302619943 by hicksd8 on Friday 6th of April 2012 12:40:31 PM
Old 04-06-2012
How are you configuring the IP address of the netboot'd server? DCHP or static ip? Is this machine on the same subnet as the system holding the flash? Is the directory holding the flash file shared to this machine?

You have a number of other options if this netboot cannot be made to work (assuming the .flar file is healthy).
 

9 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

Install of net

How do you install linux over the net? (1 Reply)
Discussion started by: macdonto
1 Replies

2. Solaris

Solaris 10 - non-interactive flash install

I have a jumpstart server setup and it's functional. I can do a standalone install no problem. I have created rules, sysidcfg, and profile files for both the standalone install and flash install. But when I try to do flash install, everything is non-interaticve up to this point (it asks me to... (1 Reply)
Discussion started by: kungpow
1 Replies

3. Solaris

Flash install ERROR

Hi, I need help because I am not able to install a created flar archive. First of all the ls of the flar: -rw-r--r-- 1 root root 5.2G Aug 6 10:23 OTS_FLASH_000_20070806.flar bash-3.00# Then the flar info: bash-3.00# flar info OTS_FLASH_000_20070806.flar... (4 Replies)
Discussion started by: joerg
4 Replies

4. HP-UX

rp 3440 flash red light and can't boot to unix

I have a rp 3440 cluster.This node restarted twice and became normal. It restarted last night and it now blinking red light. Below are logs from the console After doing Cl command. firmware Version 45.11 Duplex Console IO Dependent Code (IODC) revision 1 ******* Unexpected... (1 Reply)
Discussion started by: niggersak
1 Replies

5. Solaris

boot net problem

Hi my friends when I want to make boot net for my server I have receive: Time out ARP/RARP note: I have use Ok boot net (this is my Syntax) so what is the problem? (2 Replies)
Discussion started by: bintaleb
2 Replies

6. Solaris

How to install flash archive over the netwrok

Hi Gurus I've to install the flash archive over the network. The archive is created and directory has been shared, what else all i have to do. Once i go to install option on other system and choose FTP( flash archive only) . Will appreciate if some one can help me or directed me towards some... (9 Replies)
Discussion started by: kumarmani
9 Replies

7. Solaris

how can i install flash player

:( i download flashplayer for solaris ;but i couldnt install for firefox;please help (1 Reply)
Discussion started by: buketbarazi
1 Replies

8. Solaris

M5000 boot net- install failed

Good evening all,I'm new to your site, so please bear any infringements or transgressions on my part.I'm new to the whole Solaris boot install over the net scenario, but here's where I'm stuck:I have an M5000 with 2 domains (running unimode). Domain 0 is configured and running Solaris 10. Domain 1... (9 Replies)
Discussion started by: RandomSun
9 Replies

9. Boot Loaders

How to install grub on USB flash drive?

I wanna install grub on my flash drive for rescue usage. My computer installs winxp, and I have fedora12 installed in vmware. I did like this: step1: format the flash drive as FAT in winXP. step2: in fedora12, mount the flash drive on /media/flash step3: excute the command: grub-install... (10 Replies)
Discussion started by: vistastar
10 Replies
UPSLUG2(8)						      System Manager's Manual							UPSLUG2(8)

NAME
upslug2 - utility to upgrade the firmware of a NSLU2 via the network SYNOPSIS
upslug2 [options] DESCRIPTION
upslug2 is a command line program intended to allow the upgrade the firmware of a Linksys NSLU2 (Network Storage Link for USB 2.0 Disk Drives) to new or different versions. When a NSLU2 in the local network is put in upgrade mode, upslug2 can connect to it and upload a new firmware. upslug2 will accept a full firmware image but it can also upgrade the flash from individual files holding the kernel, ramdisk and root filesystem. upslug2 provides status information during the upgrade process and verifies the written image after the upgrade. OPTIONS
-C, --Complete-reprogram Reprogram the complete flash, including the RedBoot boot loader and the SysConf partition holding configuration information. Using this option may result in the NSLU2 becoming permanently unusable! By default, upslug2 will not touch these two partitions since this allows flashing a new firmware if an uploaded firmware does not work. This is not possible if RedBoot itself is damaged. Use with caution. -d, --device The network device on the host machine connected to the network on which the NSLU2 is located. (Default: eth0). -e, --endian The endianness of the files to be uploaded. upslug2 will usually detected the endianness automatically but this option can be used to force byte swapping to occur. This option accepts three values, separated by comma: endianness of kernel, data and RedBoot FIS directory. Valid values are l (little endian), p (pdp endian) and b (big endian). (Default: ,b,b) -f, --from The MAC address of the host system. -h, --help Show summary of options. -i, --image The complete flash image to use. -j, --rootfs A root filesystem, usually of type jffs. -k, --kernel A compressed kernel zImage image. -n, --no-reboot Do not reboot after upgrade -p, --payload FIS directory payload. There are about 140 Kb in the last block (between the FIS dir and the trailer at the end) which can be used for data. -r, --ramdisk A compressed ramdisk image. -R, --ram-payload A ram paylod (replaced ramdisk). (FIXME: if it replaced the ramdisk, why cannot you just use the -r option? What's the difference) -t, --target The MAC address of the NSLU2 to upgrade. Without this option, upslug2 will only perform an upgrade if there is just one NSLU2 in upgrade mode. -U, --no-verify Do not verify the image, only upgrade. -v, --verify Do not write to flash, only verify the image. Options to specify firmware information The following options should be used when individual kernel, ramdisk and root filesystem files are specified rather than a complete firmware image. -E, --extra-version Extra version information, a 2 byte value. (Default: 0x90f7) -F, --firmware-version The firmware version, a 2 byte value. (Default: 0x2329) -P, --product-id The product ID, a 2 byte value. (Default: 1) -T, --protocol-id The protocol ID, a 2 byte value. (Default: 0) USING UPSLUG2 In order to use upslug2 the NSLU2 which is to be upgraded has to be put in upgrade mode: 1. Disconnect any disks and/or devices from the USB ports. 2. Power off the NSLU2 3. Press and hold the reset button (accessible through the small hole on the back just above the power input). 4. Press and release the power button to power on the NSLU2. 5. Wait for 10 seconds watching the ready/status LED. After 10 seconds it will change from amber to red. Immediately release the reset but- ton. 6. The NSLU2 ready/status LED will flash alternately red/green (there is a 1 second delay before the first green). The NSLU2 is now in upgrade mode. If you decide not to flash the image the NSLU2 can be rebooted by disconnecting the power. If the ready/status LED does not turn green after step four it will remain red for several seconds then flash amber. This happens if you do not release the reset button in time - pull the power, reconnect it and repeat from the second step. Once the NSLU2 is in upgrade mode it will remain in this state until either the power is connected or a new image has been flashed. If the flash fails the NSLU2 will (eventually) return to upgrade mode EXAMPLES
The most common use of upslug2 is the following: upslug2 --image NSLU2_V23R63.bin This specifies a complete firmware image which will be written to flash. Alternatively, kernel, ramdisk and root filesystem can be specified individually: upslug2 -k nslu2-zImage -r ramdisk -j root.jffs In this case, the options -E, -F, -P and -T should typically be specified as well. By default, upslug2 will search for the NSLU2 on the network on your eth0 network interface. If the network is on a different interface, you can easily specify it: upslug2 -d eth1 --image NSLU2_V23R63.bin If there are potentially more than one NSLU2 in your network which may be in upgrade mode, you can specify its MAC address: upslug2 -t 00:11:85:12:34:56 --image NSLU2_V23R63.bin SEE ALSO
slugimage(1) AUTHOR
John Bowler <jbowler@acm.org> January 2006 UPSLUG2(8)