Sponsored Content
Operating Systems Solaris Hardware Alarms on HP-ux Solarisx86 Post 302615741 by Scrutinizer on Friday 30th of March 2012 03:48:50 AM
Old 03-30-2012
I noticed the last line says: maintenance ?
Code:
maintenance 16:16:54 svc:/application/management/hmaided:default

Also, what is
Quote:
HP-ux Solarisx86
?
 

10 More Discussions You Might Find Interesting

1. Solaris

Alarms/Alerts

Is there a imbedded command (Solaris v8 ksh) that will send an administrative alert/alarm. Or is it just triggering a mail message via shell script? If no, is there a good open-source code someone knows about? Thanks so much in advance for any replies. ...Gozer13 (3 Replies)
Discussion started by: gozer13
3 Replies

2. Shell Programming and Scripting

alarms

Hi I have been trying to set up alarms on my Solaris box (Sun OS 5.8) The objective is to present the user an audible alarm every hour or so. I have so far done this: #!/bin/sh val=1 while do printf "\a" val=`expr $val + 1` done I have put this in my crontab to run hourly.... (2 Replies)
Discussion started by: run_time_error
2 Replies

3. UNIX for Dummies Questions & Answers

Autosys Email Alarms

Hello, I'm kind of new to autosys, but I'm assuming there is a way to have Alarms be emailed instead of having to run jobscape and click the Alarm button to see what jobs have failed? Does anyone have an insight onto how this can be done? Thanks. (14 Replies)
Discussion started by: rpiller
14 Replies

4. Infrastructure Monitoring

Sun Solaris 9 Traps Contain Multiple Alarms

Hi all, I have a Sun Solaris 9 box which acts as a firewall. Sometimes if multiple actions which cause snmp traps occur very close together, a single snmp trap that is sent containing the text for multiple alarms. I would like to prevent that and have a trap sent for each action which would... (0 Replies)
Discussion started by: g0ld2k
0 Replies

5. Solaris

lp serverlist alarms in messages

Hello, I have been receiving following alarms in /var/adm/messages dtcp: WARNING DB (db_tcp.c,363) db_alloc_connid: lp && lp->serverlist error for service 20 It seems like this message is related to LP print service. Since I am not using any print service, is there any way to switch it... (2 Replies)
Discussion started by: aalishan
2 Replies

6. Solaris

Hardware faulty, but which hardware?

Hi folk, I have this hardware faunty message, but dont know which hardware is this ? can you guide me ? --------------- ------------------------------------ -------------- --------- TIME EVENT-ID MSG-ID SEVERITY ---------------... (9 Replies)
Discussion started by: dehetoxic
9 Replies

7. Solaris

Strange power supply units alarms!!!

Hi folks, I encountered this alarms on a solaris server: 04/21/12 23:17:55 MNP-PGW-A_bge3 mnp 231748 Power Supply Unit 0 is faulty 04/21/12 23:17:55 MNP-PGW-A_bge3 mnp 231748 Power Supply Unit 1 is faulty 04/21/12 23:18:26 MNP-PGW-A_bge3 mnp 231822 Power Supply Unit 0 is faulty:CLEAR... (0 Replies)
Discussion started by: kimurayuki
0 Replies

8. Solaris

Ftpd alarms

Hi, I am facing following alarms in var/adm/messages after an interval of 10 mins. I dont know what the impact is and how can i fix it. Can anyone help please? Dec 4 07:50:03 hxcsvc-a01 ftpd: open_module: stat(/usr/lib/security/pam_unix_session.so.1) failed: No such file or directory Dec ... (4 Replies)
Discussion started by: sni_engineer
4 Replies

9. Solaris

Sudden Service Busy Alarms

Hi, I am getting service busy alarms on my machines which are using MongoDB every now and then. When the service busy alarm appears, I get the following errors on my mongo router logs. Tue Apr 7 08:01:08.445 dbclient_rs nodes.ok = true hxcslc-b05:27014 Tue Apr 7 08:01:08.445 dbclient_rs... (0 Replies)
Discussion started by: sni_engineer
0 Replies

10. UNIX for Beginners Questions & Answers

CentOs server generating several alarms on partition /proc/

Greetings, I have been facing one issue here and I am not understanding what is causing. I am getting a lot of alarms complaining that the partition for example /proc/12345 , is full, but the partition does not existe on the server. Which is not supposed to happen, because /proc is not a real... (10 Replies)
Discussion started by: Yagami_Sama
10 Replies
alarm_handler(3erl)					     Erlang Module Definition					       alarm_handler(3erl)

NAME
alarm_handler - An Alarm Handling Process DESCRIPTION
The alarm handler process is a gen_event event manager process which receives alarms in the system. This process is not intended to be a complete alarm handler. It defines a place to which alarms can be sent. One simple event handler is installed in the alarm handler at start-up, but users are encouraged to write and install their own handlers. The simple event handler sends all alarms as info reports to the error logger, and saves all of them in a list which can be passed to a user defined event handler, which may be installed at a later stage. The list can grow large if many alarms are generated. So it is a good reason to install a better user defined handler. There are functions to set and clear alarms. The format of alarms are defined by the user. For example, an event handler for SNMP could be defined, together with an alarm MIB. The alarm handler is part of the SASL application. When writing new event handlers for the alarm handler, the following events must be handled: {set_alarm, {AlarmId, AlarmDescr}} : This event is generated by alarm_handler:set_alarm({AlarmId, AlarmDecsr}) . {clear_alarm, AlarmId} : This event is generated by alarm_handler:clear_alarm(AlarmId) . The default simple handler is called alarm_handler and it may be exchanged by calling gen_event:swap_handler/3 as gen_event:swap_han- dler(alarm_handler, {alarm_handler, swap}, {NewHandler, Args}) . NewHandler:init({Args, {alarm_handler, Alarms}}) is called. Refer to gen_event(3erl) for further details. EXPORTS
clear_alarm(AlarmId) -> void() Types AlarmId = term() Clears all alarms with id AlarmId . get_alarms() -> [alarm()] Returns a list of all active alarms. This function can only be used when the simple handler is installed. set_alarm(alarm()) Types alarm() = {AlarmId, AlarmDescription} AlarmId = term() AlarmDescription = term() Sets an alarm with id AlarmId . This id is used at a later stage when the alarm is cleared. SEE ALSO
error_logger(3erl), gen_event(3erl) Ericsson AB sasl 2.1.9.3 alarm_handler(3erl)
All times are GMT -4. The time now is 04:01 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy