Is there a imbedded command (Solaris v8 ksh) that will send an administrative alert/alarm. Or is it just triggering a mail message via shell script? If no, is there a good open-source code someone knows about?
Thanks so much in advance for any replies.
...Gozer13 (3 Replies)
Hi
I have been trying to set up alarms on my Solaris box (Sun OS 5.8)
The objective is to present the user an audible alarm every hour or so.
I have so far done this:
#!/bin/sh
val=1
while
do
printf "\a"
val=`expr $val + 1`
done
I have put this in my crontab to run hourly.... (2 Replies)
Hello,
I'm kind of new to autosys, but I'm assuming there is a way to have Alarms be emailed instead of having to run jobscape and click the Alarm button to see what jobs have failed? Does anyone have an insight onto how this can be done? Thanks. (14 Replies)
Hi all,
I have a Sun Solaris 9 box which acts as a firewall. Sometimes if multiple actions which cause snmp traps occur very close together, a single snmp trap that is sent containing the text for multiple alarms. I would like to prevent that and have a trap sent for each action which would... (0 Replies)
Hello,
I have been receiving following alarms in /var/adm/messages
dtcp: WARNING DB (db_tcp.c,363) db_alloc_connid: lp && lp->serverlist error for service 20
It seems like this message is related to LP print service. Since I am not using any print service, is there any way to switch it... (2 Replies)
Hi folk,
I have this hardware faunty message, but dont know which hardware is this ? can you guide me ?
--------------- ------------------------------------ -------------- ---------
TIME EVENT-ID MSG-ID SEVERITY
---------------... (9 Replies)
Hi folks,
I encountered this alarms on a solaris server:
04/21/12 23:17:55 MNP-PGW-A_bge3 mnp 231748 Power Supply Unit 0 is faulty
04/21/12 23:17:55 MNP-PGW-A_bge3 mnp 231748 Power Supply Unit 1 is faulty
04/21/12 23:18:26 MNP-PGW-A_bge3 mnp 231822 Power Supply Unit 0 is faulty:CLEAR... (0 Replies)
Hi,
I am facing following alarms in var/adm/messages after an interval of 10 mins. I dont know what the impact is and how can i fix it. Can anyone help please?
Dec 4 07:50:03 hxcsvc-a01 ftpd: open_module: stat(/usr/lib/security/pam_unix_session.so.1) failed: No such file or directory
Dec ... (4 Replies)
Hi,
I am getting service busy alarms on my machines which are using MongoDB every now and then. When the service busy alarm appears, I get the following errors on my mongo router logs.
Tue Apr 7 08:01:08.445 dbclient_rs nodes.ok = true hxcslc-b05:27014
Tue Apr 7 08:01:08.445 dbclient_rs... (0 Replies)
Greetings,
I have been facing one issue here and I am not understanding what is causing.
I am getting a lot of alarms complaining that the partition for example /proc/12345 , is full, but the partition does not existe on the server. Which is not supposed to happen, because /proc is not a real... (10 Replies)
Discussion started by: Yagami_Sama
10 Replies
LEARN ABOUT OSX
cups-snmp
cups-snmp(8) Apple Inc. cups-snmp(8)NAME
snmp - cups snmp backend
SYNOPSIS
/usr/lib/cups/backend/snmp ip-address-or-hostname
/usr/libexec/cups/backend/snmp ip-address-or-hostname
lpinfo -v --include-schemes snmp
DESCRIPTION
The CUPS SNMP backend provides legacy discovery and identification of network printers using SNMPv1. When used for discovery through the
scheduler, the backend will list all printers that respond to a broadcast SNMPv1 query with the "public" community name. Additional queries
are then sent to printers that respond in order to determine the correct device URI, make and model, and other information needed for
printing.
In the first form, the SNMP backend is run directly by the user to look up the device URI and other information when you have an IP address
or hostname. This can be used for programs that need to configure print queues where the user has supplied an address but nothing else.
In the second form, the SNMP backend is run indirectly using the lpinfo(8) command. The output provides all printers detected via SNMP on
the configured broadcast addresses. Note: no broadcast addresses are configured by default.
MIBS
The CUPS SNMP backend uses the information from the Host, Printer, and Port Monitor MIBs along with some vendor private MIBs and intelli-
gent port probes to determine the correct device URI and make and model for each printer.
CONFIGURATION
The SNMP backend reads the /etc/cups/snmp.conf configuration file, if present, to set the default broadcast address, community name, and
logging level. The configuration file is documented in cups-snmp.conf(5). The DebugLevel value can be overridden using the CUPS_DEBUG_LEVEL
environment variable and the MaxRunTime value can be overridden using the CUPS_MAX_RUN_TIME environment variable.
SEE ALSO backend(7), cups-snmp.conf(5), cupsd(8), cupsd.conf(5), filter(7), lpinfo(8),
http://localhost:631/help
COPYRIGHT
Copyright 2007-2013 by Apple Inc.
8 July 2013 CUPS cups-snmp(8)