03-24-2012
PowerHA Disk on VIO Server
Hello AIX GURU's
Can anybody tell me the steps to crate shared VG (enhanced concurent) for my Lpars from VIO server?
my questions are:
1.
Should I crate Enhanced Concurent VG in VIO and map it using virtual Scsi to Lpar?
or
2. Can I just create virtual SCSI in VIO and map to Lpar and create enhanced concurent Vg in LPAR
10 More Discussions You Might Find Interesting
1. AIX
Hi,
I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7).
I extend my vg vg000 (on the partition) and add the 2 hdisks.
I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
Discussion started by: touny
0 Replies
2. AIX
We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Discussion started by: daveisme
4 Replies
3. AIX
Hi,
I want to know wheather partition size for installation of vio client can be specified on vio server
example
If I am installing vio server on blade with 2*300gb hard disk,after that I want to create 2 vio client (AIX Operating system) wheather I can specify hard disk size while... (1 Reply)
Discussion started by: manoj.solaris
1 Replies
4. AIX
hello Folks,
my vio:
$ lsmap -all
SVSA Physloc Client Partition ID
--------------- -------------------------------------------- ------------------
vhost0 U9117.MMA.6534BE4-V2-C11 0x00000003
VTD ... (0 Replies)
Discussion started by: filosophizer
0 Replies
5. AIX
VIO Server is managing both AIX Clients and Linux Clients. For AIX Clients, we could do a disk mapping from slot numbers to VIO and also uname -L to determine the lparid and serial number frame its running on.
From a Linux Client,
How do I know which IBM frame its running on? Any command to... (4 Replies)
Discussion started by: rpangulu
4 Replies
6. AIX
Hi
I need to do the migratepv for the rootvg disks of the vio servers ? The current rootvg disks are on DMX3 storage and the new disks will be given from VMAX. Our setup is dual vio servers with multipathing to the vio clients.
What is the command to do the migratepv for the vio rootvg disks... (5 Replies)
Discussion started by: newtoaixos
5 Replies
7. AIX
Hi
In the vio server when I do # lsattr -El hdisk*, I get a PVID. The same PVID is also seen when I put the lspv command on the vio client partition. This way Im able to confirm the lun using the PVID.
Similarly how does the vio client partition gets the virtual ethernet scsi client adapter... (1 Reply)
Discussion started by: newtoaixos
1 Replies
8. AIX
Hi,
I would like to know installing vio server on local disk and mirroring rootvg,
if I am creating AIX VIO CLIENT(lpar),
and any of single local hard disk failuare.
will it affect lpars? will lpars able to boot.
what needs to be done? (1 Reply)
Discussion started by: manoj.solaris
1 Replies
9. AIX
:wall::wall::wall:
1. I have created an LPAR in the HMC.
2. I have allocated the storage from an Hitachi AMS2500 and assigned it to the host group.
3. I have zoned the LPAR and Storage on a Brocade 5100. (The zone sees the AMS)
Next I activated the LPAR in the HMC, SMS mode for the mksysb... (3 Replies)
Discussion started by: Dallasguy7
3 Replies
10. AIX
Hi,
I am facing an issue in vio server. When I run
bosboot -ad /dev/hdisk0
I am getting an error
trustchk: Verification of attributes failed: /usr/sbin/bootinfo
: accessauths
regards,
vjm
Please use code tags next time for your code and data. (8 Replies)
Discussion started by: vjm
8 Replies
LEARN ABOUT HPUX
vparutil
vparutil(1M) vparutil(1M)
NAME
vparutil - get and set SCSI parameters for SCSI controllers from a virtual partition
SYNOPSIS
dev_path
dev_path
dev_path scsi_id] scsi_rate]
DESCRIPTION
The command gets and sets SCSI parameters for SCSI controllers within a running virtual partition. When setting the SCSI parameters using
the option, the virtual partition which owns the specified SCSI controller must be in the down state. If not, the command will fail with
the appropriate error code.
The SCSI parameters for a given SCSI controller must first be set (from the firmware BCH prompt or using the option) before the parameters
can be retrieved using the option.
The command is allowed on Itanium(R)-based platforms for compatibility. No action is taken for the command.
Options
recognizes the following command-line options:
Deletes an entry for the specified SCSI controller at
dev_path from the SCSI table.
Gets the SCSI parameters for the specified SCSI controller at
dev_path.
Sets the SCSI parameters for the specified SCSI controller at
dev_path.
Operands
recognizes the following command-line operands:
dev_path The device path of the SCSI controller.
id The SCSI ID for the specified controller (defaults to 7).
rate The SCSI rate for the specified controller. This parameter can have one of two values: for the corresponding fast wide and
ultra wide SCSI interfaces.
Note
For managing SCSI controllers, use corresponding SCSI utilities. For further information refer to
SECURITY RESTRICTIONS
This command is restricted to processes owned by superuser.
When virtual partition flexible administrative capability is enabled, only a Designated-Admin vPar can set SCSI parameters for SCSI con-
trollers.
EXAMPLES
Set the SCSI ID for controller at 0/0/2/0 to 3 with the fast wide rate:
RETURN VALUE
Successful.
Invalid SCSI controller specification.
Invalid SCSI ID.
Could not communicate with virtual partition monitor.
Virtual partition which owns SCSI controller is not in down state.
Internal firmware call failed.
Other error.
AUTHOR
was developed by the Hewlett-Packard Company.
SEE ALSO
vparadmin(1M), vparboot(1M), vparcreate(1M), vparconfig(1M), vpardump(1M), vparefiutil(1M), vparenv(1M), vparextract(1M), vparmodify(1M),
vparreloc(1M), vparremove(1M), vparreset(1M), vparstatus(1M), vparresources(5), vpartition(5), vpmon(5).
vparutil(1M)