Hi,
I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7).
I extend my vg vg000 (on the partition) and add the 2 hdisks.
I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
I have a standard template I deploy for each of my AIX servers. It's in a mksysb format which I pulled via the nim server after I originally set it up.
I'm trying to restore this mksysb over the wire to a remote system. The remote system is an lpar running under vio (no HMC attached). The disk... (1 Reply)
Can you have a Dynamic LPAR without VIO and if yes is there a benefit to having both? I am attempting to implement VIO and Resource pooling at my company and want to understand the limitations.
Also, I have been told the managing and allocation of the Logical Volumes is a time consuming task as... (0 Replies)
We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR.
How can I do it without rebooting the LPARS.
POWER6 with HMC
LPARS = AIX 6.1
Any info
developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ...
But... (5 Replies)
I am wondering if there is a command I can run from **with-in** LPAR server (server01) to find out the hostname or IP address or other parameters for VIO server in charge of server01? (1 Reply)
Just a question which may seem dumb to some out there, but then again I am not a super technie so that's my excuse.
Is it possible to say provision a test AIX LPAR (has a 10gb boot lun and 20gb data) under a VIO which has connectivity to SAN Array A so it can see the disks provisioned to it,... (2 Replies)
Hi
In my vio server I have the below output
$ lsvopt | grep -i SAPSITGS
sapsitgs_cdrom TL12UP.iso 3182
In my vio client lpar I have the below output
root@sapsitgs:/ # lsdev -Cc cdromcd0 Available Virtual SCSI Optical Served by VIO Server
cd1... (1 Reply)
Discussion started by: newtoaixos
1 Replies
LEARN ABOUT DEBIAN
fence_lpar
FENCE_AGENT(8) System Manager's Manual FENCE_AGENT(8)NAME
fence_lpar - Fence agent for IBM LPAR
DESCRIPTION
fence_lpar accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent.
fence_lpar can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts.
PARAMETERS -o, --action=<action>
Fencing Action (Default Value: reboot)
-a, --ip=<ip>
IP Address or Hostname This parameter is always required.
-l, --username=<name>
Login Name This parameter is always required.
-p, --password=<password>
Login password or passphrase
-S, --password-script=<script>
Script to retrieve password
-x, --ssh
SSH connection (Default Value: 1)
-k, --identity-file=<filename>
Identity file for ssh
-n <id> Name of the partition
Partition name
-s <id> Name of the managed system
Managed system name
-H, --hmc-version=<version>
Force HMC version to use (3 or 4) (Default Value: 4)
-c, --command-prompt=<prompt>
Force command prompt (Default Value: [':~>', ']$', '$ '])
-4, --inet4-only
Forces agent to use IPv4 addresses only
-6, --inet6-only
Forces agent to use IPv6 addresses only
-u, --ipport=<port>
TCP port to use for connection with device
-v, --verbose
Verbose mode
-D, --debug-file=<debugfile>
Write debug information to given file
-V, --version
Display version information and exit
-h, --help
Display help and exit
-C, --separator=<char>
Separator for CSV created by operation list (Default Value: ,)
--power-timeout
Test X seconds for status change after ON/OFF (Default Value: 20)
--shell-timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
--login-timeout
Wait X seconds for cmd prompt after login (Default Value: 15)
--power-wait
Wait X seconds after issuing ON/OFF (Default Value: 0)
--delay
Wait X seconds before fencing is started (Default Value: 0)
--retry-on
Count of attempts to retry power on (Default Value: 1)
ACTIONS
on Power on machine.
off Power off machine.
reboot Reboot machine.
status This returns the status of the plug/virtual machine.
list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise.
monitor
Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more).
metadata
The operational behavior of this is not known.
STDIN PARAMETERS
action Fencing Action (Default Value: reboot)
ipaddr IP Address or Hostname This parameter is always required.
login Login Name This parameter is always required.
passwd Login password or passphrase
passwd_script
Script to retrieve password
secure SSH connection (Default Value: 1)
identity_file
Identity file for ssh
partition
Partition name
managed
Managed system name
hmc_version
Force HMC version to use (3 or 4) (Default Value: 4)
cmd_prompt
Force command prompt (Default Value: [':~>', ']$', '$ '])
inet4_only
Forces agent to use IPv4 addresses only
inet6_only
Forces agent to use IPv6 addresses only
ipport TCP port to use for connection with device
verbose
Verbose mode
debug Write debug information to given file
version
Display version information and exit
help Display help and exit
separator
Separator for CSV created by operation list (Default Value: ,)
power_timeout
Test X seconds for status change after ON/OFF (Default Value: 20)
shell_timeout
Wait X seconds for cmd prompt after issuing command (Default Value: 3)
login_timeout
Wait X seconds for cmd prompt after login (Default Value: 15)
power_wait
Wait X seconds after issuing ON/OFF (Default Value: 0)
delay Wait X seconds before fencing is started (Default Value: 0)
retry_on
Count of attempts to retry power on (Default Value: 1)
fence_lpar (Fence Agent) 2009-10-20 FENCE_AGENT(8)