Sponsored Content
Operating Systems AIX VIO server does not show new LPAR Post 302609807 by petervg on Tuesday 20th of March 2012 12:37:31 PM
Old 03-20-2012
VIO server does not show new LPAR

Hi All,

I've been trying to create a new LPAR for some days now but I can't get the VIO server to recognize the new LPAR. This is what I did:

  1. On HMC create new LPAR
  2. On HMC create new virtual scsi adapter for LPAR in VIO profile
  3. On HMC add new virtual scsi adapter for LPAR with DLPAR
  4. Add new virtual scsi adapater to new LPAR profile
  5. Check if VIO server sees new LPAR (lsmap -all). It doesn't show a new LPAR.
What am I missing? Why is de output of lsmap -all not showing the new LPAR vhost?


Some output:
VIO profile:
Code:
Maximum adapters: 200

Type           Adapter ID    Connection partition   Connection adapter   Required
Server SCSI    184           newlpar                 184                 Yes

VIO DLPAR:
Code:
Maximum adapters: 200

Type           Adapter ID    Connection partition   Connection adapter   Required
Server SCSI    184           newlpar                 184                 No

LPAR profile:
Code:
Maximum adapter 200

Type           Adapter ID    Connection partition   Connection adapter   Required
Server SCSI    184           vio                 184                 Yes


Last edited by petervg; 03-20-2012 at 01:50 PM..
 

10 More Discussions You Might Find Interesting

1. AIX

Help urgent : vio server - add extral disk on virtual lpar

Hi, I define 2 new LV on the vio server and run a cfgmgr on the partition and see my 2 new hdisk (hdisk6 and hdisk7). I extend my vg vg000 (on the partition) and add the 2 hdisks. I had a filesystem on the vg000 and when I added the disk I would like to increase the filesystem. But I cannot do a... (0 Replies)
Discussion started by: touny
0 Replies

2. AIX

Restoring mksysb to vio lpar?

I have a standard template I deploy for each of my AIX servers. It's in a mksysb format which I pulled via the nim server after I originally set it up. I'm trying to restore this mksysb over the wire to a remote system. The remote system is an lpar running under vio (no HMC attached). The disk... (1 Reply)
Discussion started by: scottsl
1 Replies

3. UNIX for Dummies Questions & Answers

Unix VIO vs Dynamic LPAR

Can you have a Dynamic LPAR without VIO and if yes is there a benefit to having both? I am attempting to implement VIO and Resource pooling at my company and want to understand the limitations. Also, I have been told the managing and allocation of the Logical Volumes is a time consuming task as... (0 Replies)
Discussion started by: bombers73
0 Replies

4. AIX

Lost root password in LPAR (VIO Server).

Hi, I've lost the root password in a virtual partition created in a IBM Vio Server. May I recover that somehow? Thanks (2 Replies)
Discussion started by: r4mp4g3
2 Replies

5. AIX

LPAR and vio disk mapping

We have a frame the uses 2 vios that assign disk storage to LPAR's. We have a LPAr with multiple disk and I want to know how do I tell which vio is serving the disk. For example the LPAr has hdisk 0, 1, 2, 3 all the same size. I want to know which vio is serving hdisk0, 1. (4 Replies)
Discussion started by: daveisme
4 Replies

6. AIX

VIO Backing Disk LPAR how to find which one ?

hello Folks, my vio: $ lsmap -all SVSA Physloc Client Partition ID --------------- -------------------------------------------- ------------------ vhost0 U9117.MMA.6534BE4-V2-C11 0x00000003 VTD ... (0 Replies)
Discussion started by: filosophizer
0 Replies

7. AIX

CDROM Issue on LPAR HMC VIO

Whenever I assign/unassign a CDROM ( RAID CTRL ) to Active LPAR from HMC, I have to reboot the LPAR. How can I do it without rebooting the LPARS. POWER6 with HMC LPARS = AIX 6.1 Any info developerWorks : AIX and UNIX : PowerVM Forum : Moving CD-ROM/DVD-ROM dynamically ... But... (5 Replies)
Discussion started by: filosophizer
5 Replies

8. AIX

LPAR - What is my VIO (hostname, IP, ...)

I am wondering if there is a command I can run from **with-in** LPAR server (server01) to find out the hostname or IP address or other parameters for VIO server in charge of server01? (1 Reply)
Discussion started by: ms1232
1 Replies

9. AIX

Possible to connect a LPAR to two different VIO's?

Just a question which may seem dumb to some out there, but then again I am not a super technie so that's my excuse. Is it possible to say provision a test AIX LPAR (has a 10gb boot lun and 20gb data) under a VIO which has connectivity to SAN Array A so it can see the disks provisioned to it,... (2 Replies)
Discussion started by: Johnny1314
2 Replies

10. AIX

cdrom confusion on the vio client lpar

Hi In my vio server I have the below output $ lsvopt | grep -i SAPSITGS sapsitgs_cdrom TL12UP.iso 3182 In my vio client lpar I have the below output root@sapsitgs:/ # lsdev -Cc cdromcd0 Available Virtual SCSI Optical Served by VIO Server cd1... (1 Reply)
Discussion started by: newtoaixos
1 Replies
FENCE_AGENT(8)						      System Manager's Manual						    FENCE_AGENT(8)

NAME
fence_lpar - Fence agent for IBM LPAR DESCRIPTION
fence_lpar accepts options on the command line as well as from stdin. Fenced sends parameters through stdin when it execs the agent. fence_lpar can be run by itself with command line options. This is useful for testing and for turning outlets on or off from scripts. PARAMETERS
-o, --action=<action> Fencing Action (Default Value: reboot) -a, --ip=<ip> IP Address or Hostname This parameter is always required. -l, --username=<name> Login Name This parameter is always required. -p, --password=<password> Login password or passphrase -S, --password-script=<script> Script to retrieve password -x, --ssh SSH connection (Default Value: 1) -k, --identity-file=<filename> Identity file for ssh -n <id> Name of the partition Partition name -s <id> Name of the managed system Managed system name -H, --hmc-version=<version> Force HMC version to use (3 or 4) (Default Value: 4) -c, --command-prompt=<prompt> Force command prompt (Default Value: [':~>', ']$', '$ ']) -4, --inet4-only Forces agent to use IPv4 addresses only -6, --inet6-only Forces agent to use IPv6 addresses only -u, --ipport=<port> TCP port to use for connection with device -v, --verbose Verbose mode -D, --debug-file=<debugfile> Write debug information to given file -V, --version Display version information and exit -h, --help Display help and exit -C, --separator=<char> Separator for CSV created by operation list (Default Value: ,) --power-timeout Test X seconds for status change after ON/OFF (Default Value: 20) --shell-timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) --login-timeout Wait X seconds for cmd prompt after login (Default Value: 15) --power-wait Wait X seconds after issuing ON/OFF (Default Value: 0) --delay Wait X seconds before fencing is started (Default Value: 0) --retry-on Count of attempts to retry power on (Default Value: 1) ACTIONS
on Power on machine. off Power off machine. reboot Reboot machine. status This returns the status of the plug/virtual machine. list List available plugs with aliases/virtual machines if there is support for more then one device. Returns N/A otherwise. monitor Check if fencing device is running. List available plugs/virtual machines or get status of machine (if it does not support more). metadata The operational behavior of this is not known. STDIN PARAMETERS
action Fencing Action (Default Value: reboot) ipaddr IP Address or Hostname This parameter is always required. login Login Name This parameter is always required. passwd Login password or passphrase passwd_script Script to retrieve password secure SSH connection (Default Value: 1) identity_file Identity file for ssh partition Partition name managed Managed system name hmc_version Force HMC version to use (3 or 4) (Default Value: 4) cmd_prompt Force command prompt (Default Value: [':~>', ']$', '$ ']) inet4_only Forces agent to use IPv4 addresses only inet6_only Forces agent to use IPv6 addresses only ipport TCP port to use for connection with device verbose Verbose mode debug Write debug information to given file version Display version information and exit help Display help and exit separator Separator for CSV created by operation list (Default Value: ,) power_timeout Test X seconds for status change after ON/OFF (Default Value: 20) shell_timeout Wait X seconds for cmd prompt after issuing command (Default Value: 3) login_timeout Wait X seconds for cmd prompt after login (Default Value: 15) power_wait Wait X seconds after issuing ON/OFF (Default Value: 0) delay Wait X seconds before fencing is started (Default Value: 0) retry_on Count of attempts to retry power on (Default Value: 1) fence_lpar (Fence Agent) 2009-10-20 FENCE_AGENT(8)
All times are GMT -4. The time now is 10:00 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy