Hi DukeNuke2

Thanks for the info.
The procedure that finally solved it was as follows;

To clear service led: Power off the platform, put key in service position,power on platform.


Appreciate your rapid responses


Cheers

Last edited by DukeNuke2; 03-19-2012 at 07:40 AM..
 

10 More Discussions You Might Find Interesting

1. Red Hat

Installing RedHat 8.0 onto Dell PowerEdge SC1425 - hdc: status error: status = 0x58

I have successfully installed RedHat 8.0 onto a Dell PowerEdge SC1425 today. This server has two SATA hard drives, and an IDE DVD-ROM drive. Using the following kernel parameters, i successfully installed across both hard drives from CD: ide0=0x1f0,0x3f6,14 vga=791 resolution=1024x768 expert... (5 Replies)
Discussion started by: fishsponge
5 Replies

2. SCO

Tape Status shows 2 Hard errors and 5 Underruns on new tape

when I do a tape status /dev/rStp0 I get the following on a new tape and I have tried several: Status : ready beginning-of-tape soft errors : 0 hard errors: 2 underruns: 5 My BackupEdge has stopped backing up my system because it asks for a new volume yet my total system data is under 20... (5 Replies)
Discussion started by: psytropic
5 Replies

3. UNIX for Dummies Questions & Answers

multiplication shows syntax error

my shell script is simple arithmetic process.my addtion,substract and divide all can be worked only except multiplication.please help me.the shell is following: #!/usr/bin/sh echo "enter a number1:" read number1 echo "enter an operator:" read operator echo "enter a number2:" read number2... (4 Replies)
Discussion started by: sonicstage
4 Replies

4. Solaris

Shared Storage Array is DEGRADED

Hi, On my X4200 Galaxy cluster, when i plugged out the both cables of Controller A (connected to Node 1 and Node2) , status of registered array became "Degraded". After plugging -in the cables , i should get the status of array as "OK" but i am not getting the status OK. I am using CAM... (2 Replies)
Discussion started by: deepaksharma
2 Replies

5. Solaris

* MBU_A Status:Degraded; Ver:0101h; Serial:PP095200RA ;

Hi Guru, Where is the level to run clearfault command from M3000? I only go XSCF and OS level and don't know how to get into this service level... Need to clearfault for MBU_A as show the error like * MBU_A Status:Degraded; Ver:0101h; Serial:PP095200RA ; when I run showhardconf... (2 Replies)
Discussion started by: mailbox80
2 Replies

6. Shell Programming and Scripting

Assistance Required - manipulating records

Hi guys, I need to do a bit of work to a file. Basically I want to run a SQL statement against each record in this file (hundreds of lines): sample input: 233333 233334 233335 233336 I want to do the following: 1. Add a some text at the beginning to prepare the SQL (3 lines) 2. Add... (7 Replies)
Discussion started by: mcclunyboy
7 Replies

7. Solaris

zpool status shows things NOT OK, but 3rd party raid says all is well

Hi, I've gone around with this on Oracle's site (and tech support) and ended up empty handed and without ideas of what to do to fix the problem. Background: V245, Solaris 10, has 2 12-disk infortrend RAIDs attached. Have replaced faulty disks many times - familiar with the routine. However,... (5 Replies)
Discussion started by: jdigjudy
5 Replies

8. Shell Programming and Scripting

Assistance required with awk and regular expressions

Hello there, I am trying to get my head around the section below of a script we use that incorporates AWK and Regular Expressions. { match($0,"The broker*");print $1,$2,$3 ":", substr($0, RSTART,RLENGTH)} I have a basic understanding of how match works, what I am struggling with is the... (2 Replies)
Discussion started by: jimbojames
2 Replies

9. Solaris

Zpool status shows scrub date of Dec 31, 1969

hello, We are using Solaris 11.3 on SPARC T5-2. The below is the actual output from "zpool status" command. The disks were scrubed last week, but it says the scrub repaired on Dec 31, 1969. Does anyone know how to correct this to report the correct date? Thanks pool: rpool state:... (5 Replies)
Discussion started by: jasonu
5 Replies

10. UNIX for Beginners Questions & Answers

Assistance required to decode sed search using /1

Hi, I am trying to extract line number (first number), as well as everything from TSVal onwards. 4 1.474005 172.18.124.142 -> 74.125.228.46 TCP 2450940617 74 44021 > https Seq=0 Win=5840 Len=0 MSS=1380 SACK_PERM=1 TSval=2450940617 TSecr=0 WS=64 6 1.488149 172.18.124.142 ->... (1 Reply)
Discussion started by: sand1234
1 Replies
pmconfig(1M)                                              System Administration Commands                                              pmconfig(1M)

NAME
pmconfig - Configure the Power Management system SYNOPSIS
/usr/sbin/pmconfig [-r] DESCRIPTION
The pmconfig utility sets the Power Management and suspend-resume configuration. User has permission to change Power Management configu- ration using pmconfig only if he is allowed to do so according to PMCHANGEPERM keyword of /etc/default/power. User has permission to change the suspend-resume configuration using pmconfig only if he is allowed to do so according to the CPRCHANGEPERM keyword of /etc/default/power. See FILES section below for a description of the PMCHANGEPERM and CPRCHANGEPERM keywords of /etc/default/power. Based on user permissions, pmconfig first resets the Power Management and/or suspend-resume state back to its default and then reads the new Power Management and/or suspend-resume configuration from /etc/power.conf and issues the commands to activiate the new configu- ration. The pmconfig utility is run at system boot. This utility can also be run from the command line after manual changes have been made to the /etc/power.conf file. For editing changes made to the /etc/power.conf file to take effect, users must run pmconfig. The preferred interface for changing Power Management and suspend-resume configuration is dtpower(1M). OPTIONS
The following options are supported: -r Reset Power Management and suspend-resume state to default and exit. User must have both Power Management and suspend-resume configuration permission for this option. EXIT STATUS
The following exit values are returned: 0 Upon successful completion >0 An error occurred FILES
/etc/power.conf System Power Management configuration file /etc/default/power File that controls permissions for system's Power Management and suspend-resume features. The PMCHANGEPERM key- board controls the Power Management configuration permissions, while the CPRCHANGEPERM keyword controls the sus- pend-resume configuration permissions. Allowed values are: all Any user can change the configuration. - No one except super-user can change the configuration. <user1, user2,...> A user in this user list or a super-user can change the configuration. The user list is a space and/or comma (,) separated list. You must enclose the list in < and > characters. console-owner A user who owns the system console device node or a super-user can change the configuration. The default values are PMCHANGEPERM=console-owner and CPRCHANGEPERM=console-owner. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWpmu | +-----------------------------+-----------------------------+ |Interface stability |Unstable | +-----------------------------+-----------------------------+ SEE ALSO
svcs(1), powerd(1M), power.conf(4), svcadm(1M), attributes(5), smf(5), cpr(7), pm(7D) Using Power Management NOTES
The pmconfig service is managed by the service management facility, smf(5), under the service identifier: svc:/system/power:default Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The ser- vice's status can be queried using the svcs(1) command. DIAGNOSTICS
If the program cannot open the configuration file, it prints an error message to standard error. If the program encounters a syntax error in the configuration file, it prints an error message and the line number of the error in the configuration file. It then skips the rest of the information on that line and processes the next line. Any configuration information already processed on the line containing the error is used. If user does not have permission to change Power Management and/or suspend-resume configuration, and configuration file has entries for which user doesn't have permission, it process the entries for which user has permissions and prints error on rest. SunOS 5.10 12 Aug 2004 pmconfig(1M)
All times are GMT -4. The time now is 04:23 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy