Sponsored Content
Special Forums Hardware Assistance required when booting M3000, error shows; * MBU_A Status:Degraded; Ver:0701h; Serial: Post 302608949 by DukeNuke2 on Monday 19th of March 2012 04:29:37 AM
Old 03-19-2012
first thing I would try is to get a service password from oracle (a SR has to be opened to get one) and after that use the clearfault command to reset the error.
also check that all cables to the XSCF are in the right place (serial cable on serial port; network cable on network port).
This User Gave Thanks to DukeNuke2 For This Post:
 

10 More Discussions You Might Find Interesting

1. Red Hat

Installing RedHat 8.0 onto Dell PowerEdge SC1425 - hdc: status error: status = 0x58

I have successfully installed RedHat 8.0 onto a Dell PowerEdge SC1425 today. This server has two SATA hard drives, and an IDE DVD-ROM drive. Using the following kernel parameters, i successfully installed across both hard drives from CD: ide0=0x1f0,0x3f6,14 vga=791 resolution=1024x768 expert... (5 Replies)
Discussion started by: fishsponge
5 Replies

2. SCO

Tape Status shows 2 Hard errors and 5 Underruns on new tape

when I do a tape status /dev/rStp0 I get the following on a new tape and I have tried several: Status : ready beginning-of-tape soft errors : 0 hard errors: 2 underruns: 5 My BackupEdge has stopped backing up my system because it asks for a new volume yet my total system data is under 20... (5 Replies)
Discussion started by: psytropic
5 Replies

3. UNIX for Dummies Questions & Answers

multiplication shows syntax error

my shell script is simple arithmetic process.my addtion,substract and divide all can be worked only except multiplication.please help me.the shell is following: #!/usr/bin/sh echo "enter a number1:" read number1 echo "enter an operator:" read operator echo "enter a number2:" read number2... (4 Replies)
Discussion started by: sonicstage
4 Replies

4. Solaris

Shared Storage Array is DEGRADED

Hi, On my X4200 Galaxy cluster, when i plugged out the both cables of Controller A (connected to Node 1 and Node2) , status of registered array became "Degraded". After plugging -in the cables , i should get the status of array as "OK" but i am not getting the status OK. I am using CAM... (2 Replies)
Discussion started by: deepaksharma
2 Replies

5. Solaris

* MBU_A Status:Degraded; Ver:0101h; Serial:PP095200RA ;

Hi Guru, Where is the level to run clearfault command from M3000? I only go XSCF and OS level and don't know how to get into this service level... Need to clearfault for MBU_A as show the error like * MBU_A Status:Degraded; Ver:0101h; Serial:PP095200RA ; when I run showhardconf... (2 Replies)
Discussion started by: mailbox80
2 Replies

6. Shell Programming and Scripting

Assistance Required - manipulating records

Hi guys, I need to do a bit of work to a file. Basically I want to run a SQL statement against each record in this file (hundreds of lines): sample input: 233333 233334 233335 233336 I want to do the following: 1. Add a some text at the beginning to prepare the SQL (3 lines) 2. Add... (7 Replies)
Discussion started by: mcclunyboy
7 Replies

7. Solaris

zpool status shows things NOT OK, but 3rd party raid says all is well

Hi, I've gone around with this on Oracle's site (and tech support) and ended up empty handed and without ideas of what to do to fix the problem. Background: V245, Solaris 10, has 2 12-disk infortrend RAIDs attached. Have replaced faulty disks many times - familiar with the routine. However,... (5 Replies)
Discussion started by: jdigjudy
5 Replies

8. Shell Programming and Scripting

Assistance required with awk and regular expressions

Hello there, I am trying to get my head around the section below of a script we use that incorporates AWK and Regular Expressions. { match($0,"The broker*");print $1,$2,$3 ":", substr($0, RSTART,RLENGTH)} I have a basic understanding of how match works, what I am struggling with is the... (2 Replies)
Discussion started by: jimbojames
2 Replies

9. Solaris

Zpool status shows scrub date of Dec 31, 1969

hello, We are using Solaris 11.3 on SPARC T5-2. The below is the actual output from "zpool status" command. The disks were scrubed last week, but it says the scrub repaired on Dec 31, 1969. Does anyone know how to correct this to report the correct date? Thanks pool: rpool state:... (5 Replies)
Discussion started by: jasonu
5 Replies

10. UNIX for Beginners Questions & Answers

Assistance required to decode sed search using /1

Hi, I am trying to extract line number (first number), as well as everything from TSVal onwards. 4 1.474005 172.18.124.142 -> 74.125.228.46 TCP 2450940617 74 44021 > https Seq=0 Win=5840 Len=0 MSS=1380 SACK_PERM=1 TSval=2450940617 TSecr=0 WS=64 6 1.488149 172.18.124.142 ->... (1 Reply)
Discussion started by: sand1234
1 Replies
APCSMART(8)						      Network UPS Tools (NUT)						       APCSMART(8)

NAME
apcsmart - Driver for American Power Conversion Smart Protocol UPS equipment NOTE
This man page only documents the hardware-specific features of the apcsmart driver. For information about the core driver, see nutups- drv(8). SUPPORTED HARDWARE
apcsmart should recognize all APC models that use a serial protocol at 2400 bps. This is primarily the Smart-UPS and Matrix-UPS lines, but some Back-UPS Pro models are also supported. Some older hardware may only report a handful of variables. This is usually not a bug - they just don't support anything else. CABLING
This driver expects to see a 940-0024C cable or a clone by default. You can switch to the 940-0095B dual-mode cable support with the cable= definition described below. If your 940-0024C cable is broken or missing, use this diagram to build a clone: http://www.exploits.org/nut/library/cables/940-0024C.jpg EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5): cable=940-0095B Configure the serial port for the APC 940-0095B dual-mode cable. sdtype=num Use shutdown type num, according to this table: 0: soft shutdown or powerdown, depending on battery status 1: soft shutdown followed by powerdown 2: instant power off 3: power off with grace period Modes 0 and 1 will power up the load when power returns. Modes 2 and 3 will keep the load turned off when the power returns. BUGS
Some older APC UPS models return bogus data in the status register during a front panel test. This is usually detected and discarded, but some other unexpected values have occasionally slipped through. AUTHOR
Russell Kroll SEE ALSO
The core driver: nutupsdrv(8) Internet resources: The NUT (Network UPS Tools) home page: http://www.exploits.org/nut/ NUT mailing list archives and information: http://lists.exploits.org/ Tue Oct 22 2002 APCSMART(8)
All times are GMT -4. The time now is 06:07 AM.