I have successfully installed RedHat 8.0 onto a Dell PowerEdge SC1425 today. This server has two SATA hard drives, and an IDE DVD-ROM drive.
Using the following kernel parameters, i successfully installed across both hard drives from CD:
ide0=0x1f0,0x3f6,14 vga=791 resolution=1024x768 expert... (5 Replies)
when I do a tape status /dev/rStp0 I get the following on a new tape and I have tried several:
Status : ready beginning-of-tape
soft errors : 0
hard errors: 2
underruns: 5
My BackupEdge has stopped backing up my system because it asks for a new volume yet my total system data is under 20... (5 Replies)
my shell script is simple arithmetic process.my addtion,substract and divide all can be worked only except multiplication.please help me.the shell is following:
#!/usr/bin/sh
echo "enter a number1:"
read number1
echo "enter an operator:"
read operator
echo "enter a number2:"
read number2... (4 Replies)
Hi,
On my X4200 Galaxy cluster, when i plugged out the both cables of Controller A (connected to Node 1 and Node2) , status of registered array became "Degraded".
After plugging -in the cables , i should get the status of array as "OK" but i am not getting the status OK.
I am using CAM... (2 Replies)
Hi Guru,
Where is the level to run clearfault command from M3000?
I only go XSCF and OS level and don't know how to get into this service level...
Need to clearfault for MBU_A as show the error like
* MBU_A Status:Degraded; Ver:0101h; Serial:PP095200RA ;
when I run showhardconf... (2 Replies)
Hi guys, I need to do a bit of work to a file.
Basically I want to run a SQL statement against each record in this file (hundreds of lines):
sample input:
233333
233334
233335
233336
I want to do the following:
1. Add a some text at the beginning to prepare the SQL (3 lines)
2. Add... (7 Replies)
Hi,
I've gone around with this on Oracle's site (and tech support) and ended up empty handed and without ideas of what to do to fix the problem.
Background:
V245, Solaris 10, has 2 12-disk infortrend RAIDs attached.
Have replaced faulty disks many times - familiar with the routine. However,... (5 Replies)
Hello there,
I am trying to get my head around the section below of a script we use that incorporates AWK and Regular Expressions.
{ match($0,"The broker*");print $1,$2,$3 ":", substr($0, RSTART,RLENGTH)}
I have a basic understanding of how match works, what I am struggling with is the... (2 Replies)
hello,
We are using Solaris 11.3 on SPARC T5-2. The below is the actual output from "zpool status" command. The disks were scrubed last week, but it says the scrub repaired on Dec 31, 1969.
Does anyone know how to correct this to report the correct date?
Thanks
pool: rpool
state:... (5 Replies)
Hi,
I am trying to extract line number (first number), as well as everything from TSVal onwards.
4 1.474005 172.18.124.142 -> 74.125.228.46 TCP 2450940617 74 44021 > https Seq=0 Win=5840 Len=0 MSS=1380 SACK_PERM=1 TSval=2450940617 TSecr=0 WS=64
6 1.488149 172.18.124.142 ->... (1 Reply)
Discussion started by: sand1234
1 Replies
LEARN ABOUT SUSE
irsend
IRSEND(1) FSF IRSEND(1)NAME
irsend - basic LIRC program to send infra-red commands
SYNOPSIS
irsend [options] DIRECTIVE REMOTE CODE [CODE...]
DESCRIPTION
Asks the lircd daemon to send one or more CIR (Consumer Infra-Red) commands. This is intended for remote control of electronic devices such
as TV boxes, HiFi sets, etc.
DIRECTIVE can be:
SEND_ONCE - send CODE [CODE ...] once
SEND_START - start repeating CODE
SEND_STOP - stop repeating CODE
LIST - list configured remote items
SET_TRANSMITTERS - set transmitters NUM [NUM ...]
SIMULATE - simulate IR event
REMOTE is the name of a remote, as described in the lircd configuration file.
CODE is the name of a remote control key of REMOTE, as it appears in the lircd configuration file.
NUM is the transmitter number of the hardware device.
For the LIST DIRECTIVE, REMOTE and/or CODE can be empty:
LIST "" "" - list all configured remote names
LIST REMOTE "" - list all codes of REMOTE
LIST REMOTE CODE - list only CODE of REMOTE
The SIMULATE command only works if it has been explicitly enabled in lircd.
-h --help
display usage summary
-v --version
display version
-d --device
use given lircd socket [/var/run/lirc/lircd]
-a --address=host[:port]
connect to lircd at this address
-# --count=n
send command n times
EXAMPLES
irsend LIST DenonTuner ""
irsend SEND_ONCE DenonTuner PROG-SCAN
irsend SEND_ONCE OnkyoAmpli VOL-UP VOL-UP VOL-UP VOL-UP
irsend SEND_START OnkyoAmpli VOL-DOWN ; sleep 3
irsend SEND_STOP OnkyoAmpli VOL-DOWN
irsend SET_TRANSMITTERS 1
irsend SET_TRANSMITTERS 1 3 4
irsend SIMULATE "0000000000000476 00 OK TECHNISAT_ST3004S"
FILES
/etc/lirc/lircd.conf
Default lircd configuration file. It should contain all the remotes, their infra-red codes and the corresponding timing and wave-
form details.
DIAGNOSTICS
If lircd is not running (or /var/run/lirc/lircd lacks write permissions) irsend aborts with the following diagnostics:
"irsend: could not connect to socket"
"irsend: Connection refused" (or "Permission denied").
SEE ALSO
The documentation for lirc is maintained as html pages. They are located under html/ in the documentation directory.
lircd(8), mode2(1), smode2(1), xmode2(1), irrecord(1), irw(1), http://www.lirc.org.
irsend 0.8.7pre1 May 2010 IRSEND(1)