Operating Systems AIX PowerVM HA questions Post 302605557 by gullio23 on Wednesday 7th of March 2012 06:21:28 PM
Old 03-07-2012
i have found the reply alone, but tell me if it is correct for you:

dual-vios setup with SEA failover, NPIV and sdmc, create dlpar with 2 fc virtual adapter 1 in vios1 and 1 in vios 2, create 2 virtual ethernet adapter with priority order following the primary/standby sea.

then i suppose that if i shutdown 1 server(and 1 vios) nothing happened to dlpar because it can access disks and network.
or i'm wrong? i mean i need to migrate 1st the dlpar to another physical server to failover?

this is the point that i cannot understand well because i didn't have direct experience.

can anyone help me with this?

Thanks
 

10 More Discussions You Might Find Interesting

1. AIX

PowerVM Express and IVM limitations

When using PowerVM Express and IVM (no HMC) on a Power6 P520 , can I configure 2 LPARs in addition to a VIO server, or does the VIO Server count as one of the two LPAR's that PowerVM Express allows? (1 Reply)
Discussion started by: JodyTek
1 Replies

2. AIX

Need IBM PowerVM

Hi all please give me a link for IBM PowerVM (4 Replies)
Discussion started by: babinlonston
4 Replies

3. AIX

IBM VIOS POWERVM IVM error

Hi, When I try to login on my vios ivm website http://vios through the browser -- all three of them -- firefox , chrome , Internet Explorer , i get this error http://vioserver/j_security_check I have java installed on the machine from where i am trying to open up the IVM/VIOS webpage. I... (2 Replies)
Discussion started by: filosophizer
2 Replies

4. AIX

CD-ROM issue with PowerVM IVM VIOS

I am facing problems in moving CD-ROM from one lpar to another. CDROM can be seen on the POWERVM (IVM) server , but through the web-access if I move it ( assign it ) to LPAR it will be assigned. I run cfgmgr , and the cdrom does not show up in the LPAR. I firmly believe this is the reason why I... (2 Replies)
Discussion started by: filosophizer
2 Replies

5. AIX

Implementing PowerVM without spending a single dollar

Hi experts. I want to setup a training lab. I have a Power 5 standalone server 9110-51A (p5 510) I want to enable PowerVM on it and create two LPARs I don't have money for an HMC I know I can use IVM instead I understand IVM is part of the VIOS software TWO QUESTIONS: 1- If... (12 Replies)
Discussion started by: livehho
12 Replies

6. AIX

Some questions about Intellistation 285 and powervm

Some simple questions about Intellistation 285 and powervm. I want to learn AIX,so i will buy an used I285 from ebay. 1)Will support aix 7.1? 2)Is powervm avaliable?Where to download or buy it? Thanks (3 Replies)
Discussion started by: Linusolaradm1
3 Replies

7. AIX

PowerVM/lpar creation problems

Hi, I'm a newbie to PowerVM and LPARs ( I work with VmWare and Oracle VM Server for Sparc) .recently we purchased an 8202-e4b server, with two enclosures for add'l disk capacity. it is licensed for PowerVM standard,came preloaded as such, AIX 7.1. I've set up HMC v8.2, and run it through a VM on... (30 Replies)
Discussion started by: computron
30 Replies

8. AIX

PowerVM SEA etherchannel performance ?

Hello, POWER7 machine. 4 x 1Gbit port ethernet adapter is dedicated to vios. 8023ad etherchannel is created using those 4 ports. Etherchannel adapter is shared to lpars using SEA. If I test network performance directly from vios partition (using iperf) I'm geting nice 4Gbit throughput. But if... (3 Replies)
Discussion started by: vilius
3 Replies

9. AIX

Revisiting IBM PowerVM VIOS AIX

coming from this thread: https://www.unix.com/aix/211107-ibm-power-pseries-open-firmware-boot-vios-powervm-vet-code.html PowerVM, formerly known as Advanced Power Virtualization (APV), is a chargeable feature of IBM POWER5, POWER6, POWER7, POWER8, and POWER9 servers and is required for support... (0 Replies)
Discussion started by: filosophizer
0 Replies

10. AIX

Powervm ivm vios

Hello, After installing on P6 which is POWERVM IVM VIOS enabled (VET CODE D21C77ACD9229817CA1F00002C10004164 ) i get this message "I/O hosting requires a hosting partition - boot not permitted". HMC was connected to the machine then HMC was removed through ASMI Searching on... (2 Replies)
Discussion started by: filosophizer
2 Replies
CARP(4) 						   BSD Kernel Interfaces Manual 						   CARP(4)

NAME
carp -- Common Address Redundancy Protocol SYNOPSIS
device carp DESCRIPTION
The carp interface is a pseudo-device that implements and controls the CARP protocol. CARP allows multiple hosts on the same local network to share a set of IP addresses. Its primary purpose is to ensure that these addresses are always available, but in some configurations carp can also provide load balancing functionality. A carp interface can be created at runtime using the ifconfig carpN create command or by configuring it via cloned_interfaces in the /etc/rc.conf file. To use carp, the administrator needs to configure at minimum a common virtual host ID (VHID) and virtual host IP address on each machine which is to take part in the virtual group. Additional parameters can also be set on a per-interface basis: advbase and advskew, which are used to control how frequently the host sends advertisements when it is the master for a virtual host, and pass which is used to authenticate carp advertisements. The advbase parameter stands for ``advertisement base''. It is measured in seconds and specifies the base of the advertisement interval. The advskew parameter stands for ``advertisement skew''. It is measured in 1/256 of seconds. It is added to the base advertisement interval to make one host advertise a bit slower that the other does. Both advbase and advskew are put inside CARP adver- tisements. These configurations can be done using ifconfig(8), or through the SIOCSVH ioctl(2). Additionally, there are a number of global parameters which can be set using sysctl(8): net.inet.carp.allow Accept incoming carp packets. Enabled by default. net.inet.carp.preempt Allow virtual hosts to preempt each other. It is also used to failover carp interfaces as a group. When the option is enabled and one of the carp enabled physical interfaces goes down, advskew is changed to 240 on all carp interfaces. See also the first example. Disabled by default. net.inet.carp.log Value of 0 disables any logging. Value of 1 enables logging state changes of carp interfaces. Values above 1 enable logging of bad carp packets. Default value is 1. net.inet.carp.arpbalance Balance local traffic using ARP (see below). Disabled by default. net.inet.carp.suppress_preempt A read only value showing the status of preemption suppression. Preemption can be suppressed if link on an inter- face is down or when pfsync(4) interface is not synchronized. Value of 0 means that preemption is not suppressed, since no problems are detected. Every problem increments suppression counter. ARP level load balancing The carp has limited abilities for load balancing the incoming connections between hosts in Ethernet network. For load balancing operation, one needs several CARP interfaces that are configured to the same IP address, but to a different VHIDs. Once an ARP request is received, the CARP protocol will use a hashing function against the source IP address in the ARP request to determine which VHID should this request belong to. If the corresponding CARP interface is in master state, the ARP request will be replied, otherwise it will be ignored. See the EXAMPLES section for a practical example of load balancing. The ARP load balancing has some limitations. First, ARP balancing only works on the local network segment. It cannot balance traffic that crosses a router, because the router itself will always be balanced to the same virtual host. Second, ARP load balancing can lead to asym- metric routing of incoming and outgoing traffic, and thus combining it with pfsync(4) is dangerous, because this creates a race condition between balanced routers and a host they are serving. Imagine an incoming packet creating state on the first router, being forwarded to its destination, and destination replying faster than the state information is packed and synced with the second router. If the reply would be load balanced to second router, it will be dropped due to no state. EXAMPLES
For firewalls and routers with multiple interfaces, it is desirable to failover all of the carp interfaces together, when one of the physical interfaces goes down. This is achieved by the preempt option. Enable it on both host A and B: sysctl net.inet.carp.preempt=1 Assume that host A is the preferred master and 192.168.1.x/24 is configured on one physical interface and 192.168.2.y/24 on another. This is the setup for host A: ifconfig carp0 create ifconfig carp0 vhid 1 pass mekmitasdigoat 192.168.1.1/24 ifconfig carp1 create ifconfig carp1 vhid 2 pass mekmitasdigoat 192.168.2.1/24 The setup for host B is identical, but it has a higher advskew: ifconfig carp0 create ifconfig carp0 vhid 1 advskew 100 pass mekmitasdigoat 192.168.1.1/24 ifconfig carp1 create ifconfig carp1 vhid 2 advskew 100 pass mekmitasdigoat 192.168.2.1/24 Because of the preempt option, when one of the physical interfaces of host A fails, advskew is adjusted to 240 on all its carp interfaces. This will cause host B to preempt on both interfaces instead of just the failed one. In order to set up an ARP balanced virtual host, it is necessary to configure one virtual host for each physical host which would respond to ARP requests and thus handle the traffic. In the following example, two virtual hosts are configured on two hosts to provide balancing and failover for the IP address 192.168.1.10. First the carp interfaces on host A are configured. The advskew of 100 on the second virtual host means that its advertisements will be sent out slightly less frequently. ifconfig carp0 create ifconfig carp0 vhid 1 pass mekmitasdigoat 192.168.1.10/24 ifconfig carp1 create ifconfig carp1 vhid 2 advskew 100 pass mekmitasdigoat 192.168.1.10/24 The configuration for host B is identical, except the advskew is on virtual host 1 rather than virtual host 2. ifconfig carp0 create ifconfig carp0 vhid 1 advskew 100 pass mekmitasdigoat 192.168.1.10/24 ifconfig carp1 create ifconfig carp1 vhid 2 pass mekmitasdigoat 192.168.1.10/24 Finally, the ARP balancing feature must be enabled on both hosts: sysctl net.inet.carp.arpbalance=1 When the hosts receive an ARP request for 192.168.1.10, the source IP address of the request is used to compute which virtual host should answer the request. The host which is master of the selected virtual host will reply to the request, the other(s) will ignore it. This way, locally connected systems will receive different ARP replies and subsequent IP traffic will be balanced among the hosts. If one of the hosts fails, the other will take over the virtual MAC address, and begin answering ARP requests on its behalf. SEE ALSO
inet(4), pfsync(4), rc.conf(5), ifconfig(8), sysctl(8) HISTORY
The carp device first appeared in OpenBSD 3.5. The carp device was imported into FreeBSD 5.4. BSD
January 5, 2010 BSD
All times are GMT -4. The time now is 02:05 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy