03-03-2012
a quick question:
I have one free disk plugged in the SAN Storage. It is not part of any array or hotspare coverage ( I have removed it from hotspare coverage -- )
Can I just remove the disk while the SAN is powered on and plugged into the failed disk ?
or
Do I need to shutdown the SAN Storage and remove the disk ?
--------------------
SOLUTION:
1) You can remove / unplug an ununsed powered Disk from the SAN STORAGE and use it in place of failed disk without powering off or anything
2) You can make the HOTSPARE a permanent disk provided this option is supported by the firmware level and software of DS4000
Last edited by filosophizer; 03-14-2012 at 08:44 AM..
9 More Discussions You Might Find Interesting
1. AIX
To summarize the problem: The "IBM FastT Storage Manager Client v8" shows that our Disk Farm is arranged into 6 logical drives each in a RAID 5 configuration. This software also shows that 5 of the 6 logical drives (from Disk Farm) are in a error state: "Failed Logical Drive - Drive Failure".... (1 Reply)
Discussion started by: aix-olympics
1 Replies
2. AIX
Hello,
Does anyone know how to copy SAN Storage logical disks from IBM TotalStorage Software.
I have a SAN Logical Disk of 200GB mounted on my AIX LPAR_1 via fibre channel fcs0
I would like to make an exact copy of the SAN Logical Disk from IBM totalStorage and mount it on AIX LPAR_2
... (4 Replies)
Discussion started by: filosophizer
4 Replies
3. Solaris
One more query in SVM :) Now with hot spare spool...
I can understand adding/replacing a slice in particular hot spare pool with "-a / -r" option (or) adding a slice to all existing hot spare pool with "-all" option. Here my query is for deleting, we have only option "-d".
1) If the hot... (2 Replies)
Discussion started by: gowthamakanthan
2 Replies
4. AIX
Hello,
I have AIX 6.1 with TL 4 and it is connected to IBM SAN STORAGE DS4700
After assigning some disks from SAN to AIX, I can see the disks in my AIX as
hdisk2 Available 05-00-02 MPIO Other DS4K Array Disk
hdisk3 Available 05-00-02 MPIO Other DS4K Array Disk
But it should... (0 Replies)
Discussion started by: filosophizer
0 Replies
5. Solaris
HI all,
I had recently change the Server storage from EMC to the IBM SAN.
but after the configuration, the IBM success to see the server HBA port and successfully assign a LUN for the server.
When i go to the server, and restarted it. i use the "format" command to check, but din see any... (1 Reply)
Discussion started by: SmartAntz
1 Replies
6. Solaris
Hi Guys,
Can Someone pls let me know the thorough process for Hot spare replacement
as current Hot spare slice has broken down . :mad:
Thanks
---------- Post updated at 06:34 PM ---------- Previous update was at 05:21 PM ----------
Update : Its a solaris 10 box (1 Reply)
Discussion started by: Solarister
1 Replies
7. AIX
Hello,
I have IBM SAN STORAGE DS4100 and one of the cache battery for the controller is dead. Suddenly the performance has been degraded and access to SAN disks ( reading and writing ) became very slow ?
My query: Replacing the battery will take 6 days, so in the mean time what are the ways... (1 Reply)
Discussion started by: filosophizer
1 Replies
8. AIX
Has anyone tried SAN to SAN mirroring on IBM DS SAN Storage.
DS5020 mentions Enhanced Remote Mirror to multi-LUN applications
I wonder if Oracle High availibility can be setup using Remote Mirror option of SAN ? (1 Reply)
Discussion started by: filosophizer
1 Replies
9. AIX
Hi,
This is follow up to the post https://www.unix.com/aix/233361-san-disk-appearing-double-aix.html
When I connected Pseries Machine HBA Card ( Dual Port ) directly to the SAN Storage DS4300 , I was able to see Host Port Adapter WWN numbers , although I was getting this message... (2 Replies)
Discussion started by: filosophizer
2 Replies
LEARN ABOUT HPUX
st_san_safe
st_san_safe(5) OBSOLETED st_san_safe(5)
NAME
st_san_safe - determine whether access to tape device special files without the no-rewind-on-close option is allowed (OBSOLETED)
VALUES
Failsafe
Default
Allowed values
Recommended values
or
DESCRIPTION
Note: this tunable is obsoleted and has been renamed to beginning with release HP-UX 11i v3.
This tunable notifies the tape driver whether it should allow access to device special files without the no-rewind-on-close option. When
this tunable is on the tape driver will fail any open on a tape device special file without the no-rewind-on-close option (that is, or with
a status of
The tunable allows the safe sharing of tape devices in SAN tape backup solution configurations. The disabling of device special files
without no-rewind-on-close in a SAN tape backup solution configuration prevents the accidental sending of a rewind command on close from
HP-UX systems via standard tape commands like which would corrupt a backup in process.
Who Is Expected to Change This Tunable?
Anyone.
Restrictions on Changing
Changes to this tunable take effect immediately.
When Should the Tunable Be Turned On?
This tunable should be turned on if the system is going to be used in a SAN tape backup solution configuration.
What Are the Side Effects of Turning the Tunable On?
The tape driver will fail any open to a tape device special file that does not have the no-rewind-on-close option with a status of This
behavior prevents the usage of any tape device special file without the no-rewind-on-close option.
When Should the Tunable Be Turned Off?
This tunable should be turned off if the system is not part of a SAN tape backup solution configuration or the system utilizes will not
function unless it has access to device special files without the no-rewind-on-close option.
What Are the Side Effects of Turning the Tunable Off?
A rewind may be issued from this system accidentally on close possibly corrupting a backup being issued from another system on the SAN.
What Other Tunables Should Be Changed at the Same Time?
None.
WARNINGS
All HP-UX kernel tunable parameters are release specific. This parameter may be removed or have its meaning changed in future releases of
HP-UX.
Installation of optional kernel software, from HP or other vendors, may cause changes to tunable parameter values. After installation,
some tunable parameters may no longer be at the default or recommended values. For information about the effects of installation on tun-
able values, consult the documentation for the kernel software being installed. For information about optional kernel software that was
factory installed on your system, see at
AUTHOR
was developed by Hewlett-Packard.
SEE ALSO
norewind_close_disabled(5), scsi_tape(7), scsimgr_estape(7).
Tunable Kernel Parameters st_san_safe(5)