Operating Systems Solaris Connecting an array and a tape library Post 302603863 by M_Owen on Friday 2nd of March 2012 07:38:21 AM
Old 03-02-2012
Connecting an array and a tape library

I am a solaris noob. I have a SPARC enterprise T5120 server which i am trying to connect 1 StorEdge 3300 and 1 StorageWorks MSL2024 tape library. Each device is connecting to 1 pci card on the server. I can see the array when i run the format command but i can't seem to detect the tape library.

# cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c1 scsi-sata connected configured unknown
c1::dsk/c1t0d0 disk connected configured unknown
c2 scsi-bus connected configured unknown
c2::dsk/c2t0d0 disk connected configured unknown
usb0/1 unknown empty unconfigured ok
usb0/2 unknown empty unconfigured ok
usb0/3 unknown empty unconfigured ok
usb1/1 unknown empty unconfigured ok
usb1/2 unknown empty unconfigured ok
usb2/1 unknown empty unconfigured ok
usb2/2 usb-storage connected configured ok
usb2/3 unknown empty unconfigured ok
usb2/4 usb-hub connected configured ok
usb2/4.1 unknown empty unconfigured ok
usb2/4.2 unknown empty unconfigured ok
usb2/4.3 unknown empty unconfigured ok
usb2/4.4 unknown empty unconfigured ok
usb2/5 unknown empty unconfigured ok

{0} ok probe-scsi-all
/pci@0/pci@0/pci@9/pci@0/LSILogic,scsi@8

MPT Version 1.02, Firmware Version 1.03.39.00

Initiator ID is 7

Target 6
Unit 0 Removable Tape HP Ultrium 4-SCSI B49W
Unit 1 Removable Device type 8 HP MSL G3 Series 4.40

/pci@0/pci@0/pci@8/pci@0/pci@1/pci@0/LSILogic,scsi@8

MPT Version 1.02, Firmware Version 1.03.39.00

Initiator ID is 7

Target 0
Unit 0 Disk SUN StorEdge 3310 0325 706068480 Blocks, 361 GB

/pci@0/pci@0/pci@2/scsi@0

MPT Version 1.05, Firmware Version 1.22.00.00

Target 0 Volume 0
Unit 0 Disk LSILOGICLogical Volume 3000 286617600 Blocks, 146 GB

/pci@0/pci@0/pci@1/pci@0/pci@1/pci@0/usb@0,2/storage@2
Unit 0 Removable Read Only device TSSTcorpCD/DVDW TS-T632ASR03

Any help would be appreciated.
 

10 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

ATL L200 Tape Library and Solaris

I picked up this library but I cannot get the device to actuate. How do I make this work with Solaris 7? (2 Replies)
Discussion started by: n9ninchd
2 Replies

2. HP-UX

HP-UX / Tape Library Communication Problems

Hi All, Hoping that you'll be able to help out on - I've a problem occuring in our backups that's driving me up the wall. I've got an HP-UX Visualise 6500 as below: ================================ root # uname -a HP-UX <NAME> B.11.00 A 9000/785 2005956095 two-user license... (2 Replies)
Discussion started by: geralex
2 Replies

3. AIX

Tape Library 3583

Hello every body, I have one tape library 3583 but I can't install this some body have ben installed?? when I tray to install it, the output is the next: Method error (/etc/methods/cfgAtape): 0514-022 The specified connection is not valid. some Idea?? thanks greetings (5 Replies)
Discussion started by: xanatos
5 Replies

4. AIX

Tape Library on Aix

I am having my 14 Aix 5.3 servers on bladecenters connected with my Tape Library. I had a backup scheduled on tape library but after taking backup successfully, Now, Question 1:- I wanted to restore backup but tape library could not recognize the tape and I get I/O error in TSM. I think it... (0 Replies)
Discussion started by: Shrek
0 Replies

5. Solaris

C4 tape library

Hi all , Anybody has an installation manual for Sun StorageTek C4 tape library . i am trying to do the installation on a Sun Fire V245 . Thanks a million cheers ppass (4 Replies)
Discussion started by: ppass
4 Replies

6. Solaris

Configuration issue with Tape Library in Solaris 10

Env: Server : Sparc Ultra-80 OS: Solaris 10 Direct SCSI connection to Library. Terminator connected at the Tape End. Problem: Unable to see any device file related to Robotic /dev/rsst0. Unable to see any device file /dev/rmt. ------------ Messages while the machine boots sst0: No... (3 Replies)
Discussion started by: amqstam
3 Replies

7. AIX

AIX doesn't detect TS3200 tape library

Hi all, I have a problem here root@host1 / # lsdev -Cc tape rmt0 Defined 07-00-02 IBM 3580 Ultrium Tape Drive (FCP) rmt1 Defined 07-00-02 IBM 3580 Ultrium Tape Drive (FCP) smc0 Defined 07-00-02 IBM 3573 Tape Medium Changer (FCP) root@host1 / # cfgmgr -l fcs2 Method error... (2 Replies)
Discussion started by: h@foorsa.biz
2 Replies

8. Solaris

SL24 tape library connection.

hi all please tell me how can i connect SunFire V240 to a SL24 tape library. is there any slots which i can connect? can i connect through SCSI port? (1 Reply)
Discussion started by: nikhil kasar
1 Replies

9. UNIX for Advanced & Expert Users

NDMP To Backup a Disk Array to HP B6200, EML 103e Tape Library

Hi All, Seeking information on the following and perhaps a bit of insight and opinions: I would like to look into using NDMP to backup a disk array using NetBackup 7.5 to HP B6200 StoreOnce Backup System (i.e. Virtual Tape Library) as well as physical tape library. Does anyone think... (0 Replies)
Discussion started by: zixzix01
0 Replies

10. Solaris

[Solved] Issues connecting to storage array

I have two T2000 servers connected to sun storage array StorEdge 3310 as follows: CH0 connected to SNGL BUS CONF CH1 connected to HOST1 CH2 open CH3 connected to HOST2 DUAL BUS CONF open I have created some luns which I can mount and use on HOST1 but from HOST2 I cant see them ... (3 Replies)
Discussion started by: aliyesami
3 Replies
cfgadm_pci(1M)						  System Administration Commands					    cfgadm_pci(1M)

NAME
cfgadm_pci - PCI Hotplug hardware specific commands for cfgadm SYNOPSIS
/usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -c function ap_id [ap_id] /usr/sbin/cfgadm [-f ] [-y | -n ] [-v] [-o hardware_options] -x hardware_function ap_id [ap_id] /usr/sbin/cfgadm [-v] [-s listing_options] [-o hardware_options] [-l [ ap_id | ap_type]] /usr/sbin/cfgadm [-v] [-o harware_options] -t ap_id [ap_id] /usr/sbin/cfgadm [-v] [-o hardware_function] -h [ ap_id| ap_type] DESCRIPTION
The PCI hardware specific library /usr/lib/cfgadm/pci.so.1 provides the support for hot plugging pci adapter cards into pci hot pluggable slots in a system that is hot plug capable, through the cfgadm command. See cfgadm(1M). For PCI Hot Plug, each hot plug slot on a specific PCI bus is represented by an attachment point of that specific PCI bus. An attachment point consist of two parts: a receptacle and an occupant. The receptacle under PCI hot plug is usually referred to as the physical hot pluggable slot; and the occupant is usually referred to as the PCI adapter card that plugs into the slot. Attachment points are named through ap_ids. There are two types of ap_ids: logical and physical. The physical ap_id is based on the physi- cal pathname, that is, /devices/pci@1/hpc0_slot3, whereas the logical ap_id is a shorter, and more user-friendly name. For PCI hot plug- gable slots, the logical ap_id is usually the corresponding hot plug controller driver name plus the logical slot number, that is, pci0:hpc0slot1; pci nexus driver, with hot plug controller driver named hpc and slot number 1. The ap_type for Hot plug PCI is pci. Note that the ap_type is not the same as the information in the Type field. See the System Administration Guide: Basic Administration for a detailed description of the hot plug procedure. OPTIONS
The following options are supported: -c function The following functions are supported for PCI hot pluggable slots: configure Configure the PCI device in the slot to be used by Solaris. connect Connect the slot to PCI bus. disconnect Disconnect the slot from the PCI bus. insert Not supported. remove Not supported. unconfigure Logically remove the PCI device's resources from the system. -f Not supported. -h ap_id | ap_type Print out PCI hot plug specific help message. -l list List the values of PCI Hot Plug slots. -o hardware_options No hardware specific options are currently defined. -s listing_options Same as the generic cfgadm(1M). -t ap_id This command is only supported on platforms which support testing capability on the slot. -v Execute in verbose mode. When -v is used with -l option the cfgadm command outputs information about the attachment point. For PCI Hot Plug, the Information field will be the slot's system label. This string will be obtained from the slot-name property of the slot's bus node. The information in the Type field is printed with or without the -v option. The occupant Type field will describe the contents of the slot. There are 2 possible values: unknown The slot is empty. If a card is in the slot, the card is not configured or there is no driver for the device on the card. subclass/board The card in the slot is either a single-function or multi-function device. subclass is a string representing the subclass code of the device, for example, SCSI, ethernet, pci-isa, and so forth. If the card is a multi-functional device, MULT will get printed instead. board is a string representing the board type of the device. For example, hp is the string used for a PCI Hot Plug adapter, hs is used for a Hot Swap Board, nhs for a Non--Hot Swap cPCI Board, bhs for a Basic Hot Swap cPCI Board, and fhs for a Full Hot Swap cPCI Board. Most pci cards with more than one device are not multi-function devices, but are implemented as a pci bridges with arbitrary devices behind them. In those cases, the subclass displayed is that of the pci bridge. Most com- monly the bridges are pci-pci, a generic pci to pci bridge or stpci, a semi-transparent pci bridge. -x hardware_function Perform hardware specific function. These hardware specific functions should not normally change the state of a receptacle or occupant. The following hardware_functions are supported: enable_slot | disable_slot Change the state of the slot and preserve the state of slot across reboot. Preservation of state across reboot is only supported on select platforms. enable_slot enables the addition of hardware to this slot for hot plugging and at boot time. disable_slot disables the addition of hardware to this slot for hot plugging and at boot time. When a slot is disabled its condi- tion is shown as unusable. enable_autoconfig | disable_autoconfig Change the ability to autoconfigure the occupant of the slot. Only platforms that support auto configuration support this feature. enable_autoconfig enables the ability to autoconfigure the slot. diable_autoconfig disables the ability to autoconfigure the slot. led=[led_sub_arg],mode=[mode_sub_arg] Without sub-arguments, print a list of the current LED settings. With sub-arguments, set the mode of a specific LED for a slot. Specify led_sub_arg as fault, power, att, or active. Specify mode_sub_arg as on, off or blink. Changing the state of the LED does not change the state of the receptacle or occupant. Normally, the LEDs are controlled by the hot plug controller, no user intervention is necessary. Use this command for testing purposes. Caution: Changing the state of the LED can misrepresent the state of occupant or receptacle. The following command prints the values of LEDs: example# cfgadm -x led pci0:hpc0_slot1 Ap_Id Led pci0:hpc0_slot1 power=on,fault=off,active=off,attn=off The following command turns on the Fault LED: example# cfgadm -x led=fault,mode=on pci0:hpc0_slot1 The following command turns off the Power LED: example# cfgadm -x led=power,mode=off pci0:hpc0_slot0 The following command sets the active LED to blink to indicate the location of the slot: example# cfgadm -x led=active,mode=on pci0:hpc0_slot3 EXAMPLES
Example 1: Printing out the Value of Each Slot The following command prints out the values of each slot: example# cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok Example 2: Replacing a Card The following command lists all DR-capable attachment points: example# cfgadm Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c1 scsi-bus connected unconfigured unknown c2 scsi-bus connected unconfigured unknown cpci_slot1 stpci/fhs connected configured ok cpci_slot2 unknown empty unconfigured unknown cpci_slot4 stpci/fhs connected configured ok cpci_slot5 stpci/fhs connected configured ok The following command unconfigures and electrically disconnects the card: example# cfgadm -c disconnect cpci_slot4 The change can be verified by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 unknown disconnected unconfigured unknown Now the card can be swapped. The following command electrically connects and configures the card: example# cfgadm -c configure cpci_slot4 The change can be verifed by entering the following command: example# cfgadm cpci_slot4 Ap_Id Type Receptacle Occupant Condition cpci_slot4 stpcipci/fhs connected configured ok FILES
/usr/lib/cfgadm/pci.so.1 Hardware specific library for PCI hot plugging. ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWkvm.u | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5) System Administration Guide: Basic Administration SunOS 5.10 27 Oct 2003 cfgadm_pci(1M)
All times are GMT -4. The time now is 01:05 PM.