03-02-2012
Does this still happen if you power cycle the machine? I do mean close down and remove the actual mains cables completely. When you reinsert the power only the SC will boot up to the "login". Same problem??
10 More Discussions You Might Find Interesting
1. UNIX for Advanced & Expert Users
No, its not a movie, its a command to get you from the sc> ALOM prompt back to the console or ok prompt.
You must log into the ALOM, then to jump back to the console enter "console -f".
Problem is that this leaves you logged in on the ALOM.
Question: is there an escape key sequence to get... (1 Reply)
Discussion started by: jsy
1 Replies
2. Solaris
Hello Guys,
I am working with sunfire V480 and wants to know how to connect to alom. Can you please guide? (7 Replies)
Discussion started by: mokkan
7 Replies
3. Solaris
hello guys.... I'm newbie in solaris server / os, anybody know how disable alom server v240.
thank u (9 Replies)
Discussion started by: yanto85
9 Replies
4. Solaris
Hi guys,
I'm in trouble with a Sunfire T2000.
The OS (Solaris10) is up and running, but I can't log in the sc>I think the terminal server is crashed!
Does anyone know if I can reset the sc> from the OS?
How can I do that?
Thx (6 Replies)
Discussion started by: cecco16
6 Replies
5. Solaris
Hi Everyone.
What is the differece b/n ALOM and ALOM CMT Service processor.
I am trying reset ALOM login/passwd using scadm utility on T2000, while I am googling I came cross ALOM CMT doesnt support scadm utility, but ALOM supports.
Not sure how different are these.
Thanks, (0 Replies)
Discussion started by: bobby320
0 Replies
6. Solaris
Hi gurus,
I have a sun netra 240 server. I want to get to the ALOM but it always ask for login and password. Can anyone tell me how I can reset the ALOM it to default so I can be able to configure it?
Thanks lots. (2 Replies)
Discussion started by: cjashu
2 Replies
7. Solaris
Hello forum,
I have a SUN v250 at home that I have to practice Solaris. I currently have Solaris 9 installed and the ALOM Sun(tm) Advanced Lights Out Manager 1.5.2.
From the ALOM I want to access the console.
sc> console -f
Enter #. to return to ALOM.
after that there is no response.... (19 Replies)
Discussion started by: br1an
19 Replies
8. Solaris
Hi guys,
I'm new with solaris.
I just received sunfire T2000 server.
Problem:
ALOM keep hang/stuck/jammed.
Steps do before it hang :
1. Connect to T2000 (using RJ45 - DB9 cable)
2. Open putty, connect via serial.
3. Power on the server.
4. Its loading.
5. then, hang.
... (1 Reply)
Discussion started by: rajasraf
1 Replies
9. Solaris
Hi,
How to set ip address on eth0 for access ssh from ALOM? Is it possible? Now i cannot access it because don't have VGA.
I keep try to access using ssh. Please guide me.
Thanks. (16 Replies)
Discussion started by: mzainal
16 Replies
10. Hardware
Hi all,
I have some problems with the fan FT0.F0, which looks like has a problem with the PROM/ALOM ( I am nor sure who).....but, in fact, the fan is working properly even in other V440 Sparc Server.
We checked HW comunication between Fan and the MotherBoard, and we think is a problem of... (8 Replies)
Discussion started by: proof_enrique
8 Replies
LEARN ABOUT FREEBSD
safenet
SAFENET(8) NUT Manual SAFENET(8)
NAME
safenet - Driver for SafeNet compatible UPS equipment
NOTE
This man page only documents the hardware-specific features of the safenet driver. For information about the core driver, see nutupsdrv(8).
SUPPORTED HARDWARE
This driver supports UPS equipment which can be controlled via SafeNet v1.0 for Windows (serial interface only).
EXTRA ARGUMENTS
This driver supports the following optional settings in the ups.conf(5) file:
manufacturer=value
Autodetection of this parameter is not possible yet (and it probably never will be). Therefore, this user-defined string accepts any
name. The default is unknown.
modelname=value
Like manufacturer above. The default is unknown.
serialnumber=value
Like manufacturer above. The default is unknown.
ondelay=value
Time to wait before switching on the UPS (minutes). Defaults to 1 minute.
offdelay=value
Time to wait before shutting down the UPS (seconds). Defaults to 30 seconds.
UPSCMD
This driver supports some instant commands (see upscmd(8)):
test.battery.start
Start UPS self test
test.battery.stop
Cancel UPS self test
test.failure.start
Start simulated power failure
test.failure.stop
Cancel simulated power failure
beeper.enable
Enable the UPS beeper
beeper.mute
Temporarily mute the UPS beeper
beeper.toggle
Toggle the UPS beeper
shutdown.return
Turn off the load and wait for the power to return. Uses the timer defined by offdelay.
shutdown.reboot
Turn off the load and return. Uses the timers defined by offdelay and ondelay.
KNOWN PROBLEMS
If you run the shutdown.return command with mains present, the output may stay on or switch off and not back on again. The shutdown.reboot
command will unconditionally switch on the load again (with or without mains present).
If the driver is called with the -k option (or through upsdrvctl shutdown) it tries to detect which command should be used in an attempt to
stay off until mains is present again or to cycle the output if the power returned in the mean time. This isn't bullet-proof, and you
should be prepared that the power will either not be shutdown, or that it doesn't return when the power comes back.
AUTHOR
Arjen de Korte <adkorte-guest at alioth.debian.org>
SEE ALSO
The core driver:
nutupsdrv(8)
Internet resources:
The NUT (Network UPS Tools) home page: http://www.networkupstools.org/
Network UPS Tools 05/21/2012 SAFENET(8)