Sponsored Content
Operating Systems Solaris Hardware RAID not recognize the new disk [Sun T6320] Post 302599084 by little2712 on Thursday 16th of February 2012 06:58:13 AM
Old 02-16-2012
yes i also face this type of problems once a time,,where LBA,s are not the same due to which we have order other disk with same LBA..plz check that part number should be same...
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

Sun T5120 hardware RAID question

Hi everyone I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive. My question is, how would I know when one of the drives become faulty? Thanks (2 Replies)
Discussion started by: soliberus
2 Replies

3. Solaris

Add new disk to Sun StorEdge 3310 RAID

HI guys. Bit of a noob so bear with me. I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies

4. Hardware

Sun Blade T6320 memory configuration

Can you mix DIMMs in a T6320 (sparc) blade? I have read/heard that the DIMMs in a memory bay must be identical but can you have different size DIMMs installed in the blade? For instance, can you have 1 4GB DIMM in bay 0, 2 2GB DIMMs in bay 1, 4 1 GB DIMMs in bay 2 and 2 2GB DIMMs in bay 3 for a... (0 Replies)
Discussion started by: bluescreen
0 Replies

5. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

6. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

7. Solaris

Solaris recognize HW Raid ??

Hardware: HP P2000 HP DL380 G7 with Solaris Software: Solaris 10 05/08 I had made a Hardware raid on P2000 and install solaris on G7, The raid card controller is working fine. How can I make the raid works on OS?? "raidclt" is getting nothing :wall::wall: Thanks (11 Replies)
Discussion started by: stanley1024
11 Replies

8. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

9. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies
SG_REFERRALS(8) 						     SG3_UTILS							   SG_REFERRALS(8)

NAME
sg_referrals - send the SCSI REPORT REFERRALS command SYNOPSIS
sg_referrals [--help] [--hex] [--lba=LBA] [--maxlen=LEN] [--one-segment] [--raw] [--verbose] [--version] DEVICE DESCRIPTION
Send the SCSI REPORT REFERRALS command to the DEVICE and outputs the response. This command was introduced in (draft) SBC-3 revision 24 and devices that support referrals should support this command. The default action is to decode the response for all user data segment referral descriptors. The amount of output can be reduced by the --lba and --one-segment options. OPTIONS
Arguments to long options are mandatory for short options as well. -h, --help output the usage message then exit. -H, --hex output response to this command in ASCII hex. -l, --lba=LBA where LBA is the Logical Block Address (LBA) in the first user data segment the DEVICE should report the referrals parameter data for. -m, --maxlen=LEN where LEN is the (maximum) response length in bytes. It is placed in the cdb's "allocation length" field. If not given then 256 is used. 256 is enough space for the response header and user data segment descriptors. -s, --one-segment report the user data segment of the segment spefified by the LBA parameter only. -r, --raw output response in binary (to stdout). -v, --verbose increase the level of verbosity, (i.e. debug output). Additional output caused by this option is sent to stderr. -V, --version print the version string and then exit. NOTES
For a discussion of referrals see section 4.25 of sbc3r25.pdf at http://www.t10.org (or the corresponding section of a later draft). EXIT STATUS
The exit status of sg_referrals is 0 when it is successful. Otherwise see the sg3_utils(8) man page. AUTHORS
Written by Douglas Gilbert and Hannes Reinecke. REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>. COPYRIGHT
Copyright (C) 2009-2010 Douglas Gilbert and Hannes Reinecke This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR- POSE. SEE ALSO
sg_vpd(8) sg3_utils-1.30 November 2010 SG_REFERRALS(8)
All times are GMT -4. The time now is 08:17 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy