02-16-2012
yes i also face this type of problems once a time,,where LBA,s are not the same due to which we have order other disk with same LBA..plz check that part number should be same...
9 More Discussions You Might Find Interesting
1. Solaris
I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies
2. Solaris
Hi everyone
I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive.
My question is, how would I know when one of the drives become faulty?
Thanks (2 Replies)
Discussion started by: soliberus
2 Replies
3. Solaris
HI guys.
Bit of a noob so bear with me.
I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies
4. Hardware
Can you mix DIMMs in a T6320 (sparc) blade? I have read/heard that the DIMMs in a memory bay must be identical but can you have different size DIMMs installed in the blade?
For instance, can you have 1 4GB DIMM in bay 0, 2 2GB DIMMs in bay 1, 4 1 GB DIMMs in bay 2 and 2 2GB DIMMs in bay 3 for a... (0 Replies)
Discussion started by: bluescreen
0 Replies
5. UNIX for Dummies Questions & Answers
Hi
Can someone tell me what are the differences between software and hardware raid ?
thx for help. (2 Replies)
Discussion started by: presul
2 Replies
6. Hardware
Hi All
I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command.
Following is the hardware RAID output.
root@oracledatabaseserver / $ raidctl
RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies
7. Solaris
Hardware:
HP P2000
HP DL380 G7 with Solaris
Software:
Solaris 10 05/08
I had made a Hardware raid on P2000 and install solaris on G7,
The raid card controller is working fine.
How can I make the raid works on OS??
"raidclt" is getting nothing :wall::wall:
Thanks (11 Replies)
Discussion started by: stanley1024
11 Replies
8. Hardware
Hi all
I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS.
The documentation doesn't make it clear if:
1. The... (6 Replies)
Discussion started by: soliberus
6 Replies
9. Solaris
Server Model: T5120 with 146G x4 disks.
OS: Solaris 10 - installed on c1t0d0.
Plan to use software raid (veritas volume mgr) on c1t2d0 disk.
After format and label the disk, still not able to detect using vxdiskadm.
Question:
Should I remove the hardware raid on c1t2d0 first?
My... (4 Replies)
Discussion started by: KhawHL
4 Replies
LEARN ABOUT DEBIAN
sg_referrals
SG_REFERRALS(8) SG3_UTILS SG_REFERRALS(8)
NAME
sg_referrals - send the SCSI REPORT REFERRALS command
SYNOPSIS
sg_referrals [--help] [--hex] [--lba=LBA] [--maxlen=LEN] [--one-segment] [--raw] [--verbose] [--version] DEVICE
DESCRIPTION
Send the SCSI REPORT REFERRALS command to the DEVICE and outputs the response. This command was introduced in (draft) SBC-3 revision 24 and
devices that support referrals should support this command.
The default action is to decode the response for all user data segment referral descriptors. The amount of output can be reduced by the
--lba and --one-segment options.
OPTIONS
Arguments to long options are mandatory for short options as well.
-h, --help
output the usage message then exit.
-H, --hex
output response to this command in ASCII hex.
-l, --lba=LBA
where LBA is the Logical Block Address (LBA) in the first user data segment the DEVICE should report the referrals parameter data
for.
-m, --maxlen=LEN
where LEN is the (maximum) response length in bytes. It is placed in the cdb's "allocation length" field. If not given then 256 is
used. 256 is enough space for the response header and user data segment descriptors.
-s, --one-segment
report the user data segment of the segment spefified by the LBA parameter only.
-r, --raw
output response in binary (to stdout).
-v, --verbose
increase the level of verbosity, (i.e. debug output). Additional output caused by this option is sent to stderr.
-V, --version
print the version string and then exit.
NOTES
For a discussion of referrals see section 4.25 of sbc3r25.pdf at http://www.t10.org (or the corresponding section of a later draft).
EXIT STATUS
The exit status of sg_referrals is 0 when it is successful. Otherwise see the sg3_utils(8) man page.
AUTHORS
Written by Douglas Gilbert and Hannes Reinecke.
REPORTING BUGS
Report bugs to <dgilbert at interlog dot com>.
COPYRIGHT
Copyright (C) 2009-2010 Douglas Gilbert and Hannes Reinecke
This software is distributed under a FreeBSD license. There is NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PUR-
POSE.
SEE ALSO
sg_vpd(8)
sg3_utils-1.30 November 2010 SG_REFERRALS(8)