Sponsored Content
Operating Systems Solaris Hardware RAID not recognize the new disk [Sun T6320] Post 302598391 by DukeNuke2 on Tuesday 14th of February 2012 09:54:42 AM
Old 02-14-2012
hmm... i would pull the disk out and after 1 minute put it back in to see if it is recognized by the raid controller.
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

Sun T5120 hardware RAID question

Hi everyone I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive. My question is, how would I know when one of the drives become faulty? Thanks (2 Replies)
Discussion started by: soliberus
2 Replies

3. Solaris

Add new disk to Sun StorEdge 3310 RAID

HI guys. Bit of a noob so bear with me. I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies

4. Hardware

Sun Blade T6320 memory configuration

Can you mix DIMMs in a T6320 (sparc) blade? I have read/heard that the DIMMs in a memory bay must be identical but can you have different size DIMMs installed in the blade? For instance, can you have 1 4GB DIMM in bay 0, 2 2GB DIMMs in bay 1, 4 1 GB DIMMs in bay 2 and 2 2GB DIMMs in bay 3 for a... (0 Replies)
Discussion started by: bluescreen
0 Replies

5. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

6. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

7. Solaris

Solaris recognize HW Raid ??

Hardware: HP P2000 HP DL380 G7 with Solaris Software: Solaris 10 05/08 I had made a Hardware raid on P2000 and install solaris on G7, The raid card controller is working fine. How can I make the raid works on OS?? "raidclt" is getting nothing :wall::wall: Thanks (11 Replies)
Discussion started by: stanley1024
11 Replies

8. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

9. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies
smd-pull(1)						 Sync Mail Dir (smd) documentation					       smd-pull(1)

NAME
smd-pull - syncs the local mail dir letting the remote one untouched SYNOPSIS
smd-pull [-d|--dry-run] [-v|--verbose] [-s|--show-tags] [-t|--template-only] [-n|--no-delete] [endpoint] DESCRIPTION
smd-pull performs in the local maildir all the changes that were performed on remote one. No changes are made on the remote maildir. Use smd-push(1) for that. Refer to smd-config(5) for the configuration file format. OPTIONS
-v --verbose Verbose output -s --show-tags Machine readable output -d --dry-run Do not perform any action for real -n --no-delete Do not propagate deletions -t --template-only Just create a template configuration file if none endpoint Is the suffix for the name of the configuration file to use. If it is omitted, the configuration file ~/.smd/config.default is used. FILES
~/.smd/config.* ~/.smd/hooks/pre-pull.d/ ~/.smd/hooks/post-pull.d/ SEE ALSO
mddiff(1), smd-server(1), smd-client(1), smd-push(1), smd-loop(1), smd-config(5) AUTHOR
Enrico Tassi <gares@fettunta.org> 11 June 2012 smd-pull(1)
All times are GMT -4. The time now is 10:07 AM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy