Sponsored Content
Operating Systems Solaris Hardware RAID not recognize the new disk [Sun T6320] Post 302598391 by DukeNuke2 on Tuesday 14th of February 2012 09:54:42 AM
Old 02-14-2012
hmm... i would pull the disk out and after 1 minute put it back in to see if it is recognized by the raid controller.
 

9 More Discussions You Might Find Interesting

1. Solaris

Hardware RAID

I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies

2. Solaris

Sun T5120 hardware RAID question

Hi everyone I've just purchased a Sun T5120 server with 2 internal disks. I've configured hardware RAID (mirror) and as a result the device tree in Solaris only contains 1 hard drive. My question is, how would I know when one of the drives become faulty? Thanks (2 Replies)
Discussion started by: soliberus
2 Replies

3. Solaris

Add new disk to Sun StorEdge 3310 RAID

HI guys. Bit of a noob so bear with me. I have 2 new disks I want to add to my StorEdge 3310 but am getting lost in the steps. We have another 3310 (JBOD) that I was able to plug the disks into and they instantly showed up. Did a few minor commands after (drvconfig, devfsadm etc..) and I was... (4 Replies)
Discussion started by: jamie_collins
4 Replies

4. Hardware

Sun Blade T6320 memory configuration

Can you mix DIMMs in a T6320 (sparc) blade? I have read/heard that the DIMMs in a memory bay must be identical but can you have different size DIMMs installed in the blade? For instance, can you have 1 4GB DIMM in bay 0, 2 2GB DIMMs in bay 1, 4 1 GB DIMMs in bay 2 and 2 2GB DIMMs in bay 3 for a... (0 Replies)
Discussion started by: bluescreen
0 Replies

5. UNIX for Dummies Questions & Answers

RAID software vs hardware RAID

Hi Can someone tell me what are the differences between software and hardware raid ? thx for help. (2 Replies)
Discussion started by: presul
2 Replies

6. Hardware

Hardware RAID on Sun T2000 Server

Hi All I have a Sun T2000 server. Couple of years ago I had configured and mirrored the boot drive with an other drive using hardware RAID 1 using raidctl command. Following is the hardware RAID output. root@oracledatabaseserver / $ raidctl RAID Volume RAID RAID Disk... (0 Replies)
Discussion started by: Tirmazi
0 Replies

7. Solaris

Solaris recognize HW Raid ??

Hardware: HP P2000 HP DL380 G7 with Solaris Software: Solaris 10 05/08 I had made a Hardware raid on P2000 and install solaris on G7, The raid card controller is working fine. How can I make the raid works on OS?? "raidclt" is getting nothing :wall::wall: Thanks (11 Replies)
Discussion started by: stanley1024
11 Replies

8. Hardware

Sun T3-1 hardware RAID

Hi all I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS. The documentation doesn't make it clear if: 1. The... (6 Replies)
Discussion started by: soliberus
6 Replies

9. Solaris

Software RAID on top of Hardware RAID

Server Model: T5120 with 146G x4 disks. OS: Solaris 10 - installed on c1t0d0. Plan to use software raid (veritas volume mgr) on c1t2d0 disk. After format and label the disk, still not able to detect using vxdiskadm. Question: Should I remove the hardware raid on c1t2d0 first? My... (4 Replies)
Discussion started by: KhawHL
4 Replies
chs(7D) 							      Devices								   chs(7D)

NAME
chs - IBM ServeRAID PCI host adapter driver DESCRIPTION
The chs driver is the IBM ServeRAID PCI controller driver. PRECONFIGURATION
Known Problems and Limitations To prevent data loss, a SCSI disk drive that is not defined as part of any physical pack within a logical drive will not be accessible through the Solaris operating environment. CONFIGURATION
Auto-configuration code determines whether the adapter is present at the configured address and what types of devices are attached to it. The IBM ServeRAID is primarily used as a disk array (system drive) controller. To configure the attached disk arrays, you must configure the controller (using the configuration utilities provided by the hardware manu- facturer) before booting the Solaris operating environment You use the configuration utilities to set RAID levels, stripe parameters, cache mechanisms and perform other functions. For more information, see the user manual supplied with your hardware. FILES
/kernel/drv/chs.conf chs configuration file /dev/dsk/cndn[s|p]n block device /dev/rdsk/cndn[s|p]n raw device where: cn controller n dn LUN n (0-7) sn UNIX system slice n (0-15) pn fdisk(1M) partition(0) ATTRIBUTES
See attributes(5) for a description of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | |Architecture |x86 | +-----------------------------+-----------------------------+ SEE ALSO
fdisk(1M), attributes(5), cmdk(7D) SunOS 5.10 27 November 2000 chs(7D)
All times are GMT -4. The time now is 10:58 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.