Sponsored Content
Full Discussion: disk replacment, SUN M3000
Homework and Emergencies Emergency UNIX and Linux Support disk replacment, SUN M3000 Post 302594988 by robsonde on Wednesday 1st of February 2012 05:51:07 PM
Old 02-01-2012
Network disk replacment, SUN M3000

we have a SUN M3000 server.
setup as only 1 domain.

disk c0t0d0 and c0t1d0 and setup as SVM mirrors.

a few days ago disk T1 failed.
new we have replaced the disk, but can's see the disk in format.

have done cfgadm and devfsadm.
still can't access the new disk in format.


the output of some command that maybe of help...
Code:
# uname -a
SunOS server_name 5.10 Generic_144488-08 sun4u sparc SUNW,SPARC-Enterprise

# cfgadm -al
Ap_Id                          Type         Receptacle   Occupant     Condition
SB0                            System_Brd   connected    configured   ok
SB0::cpu0                      cpu          connected    configured   ok
SB0::memory                    memory       connected    configured   ok
SB0::pci0                      io           connected    configured   ok
SB0::pci1                      io           connected    configured   ok
SB0::pci8                      io           connected    configured   ok
c0                             scsi-sata    connected    configured   unknown
c0::dsk/c0t0d0                 disk         connected    configured   unknown
c0::dsk/c0t1d0                 disk         connected    configured   unknown
c0::dsk/c0t2d0                 disk         connected    configured   unknown
c0::dsk/c0t3d0                 disk         connected    configured   unknown
c0::dsk/c0t4d0                 CD-ROM       connected    configured   unknown
c1                             fc-fabric    connected    configured   unknown
c1::50001fe1500d1f78           array-ctrl   connected    configured   unknown
c1::50001fe1500d1f7c           array-ctrl   connected    configured   unknown

# format
Searching for disks...done


AVAILABLE DISK SELECTIONS:
       0. c0t0d0 <FUJITSU-MBD2147RC-3701 cyl 14087 alt 2 hd 24 sec 848>
          /pci@0,600000/pci@0/pci@0/scsi@0/sd@0,0
       1. c0t2d0 <FUJITSU-MBD2300RC-3701-279.40GB>
          /pci@0,600000/pci@0/pci@0/scsi@0/sd@2,0
       2. c0t3d0 <FUJITSU-MBD2300RC-3701-279.40GB>
          /pci@0,600000/pci@0/pci@0/scsi@0/sd@3,0
       3. c1t50001FE1500D1F7Cd1 <HP-HSV200-6240-25.00GB>
          /pci@1,700000/pci@0/pci@9/SUNW,qlc@0/fp@0,0/ssd@w50001fe1500d1f7c,1
       4. c1t50001FE1500D1F78d1 <HP-HSV200-6240-25.00GB>
          /pci@1,700000/pci@0/pci@9/SUNW,qlc@0/fp@0,0/ssd@w50001fe1500d1f78,1
Specify disk (enter its number): ^D

what magic is needed to make Solaris access the disk?



50K bits to anyone who can solve this problem.
 

8 More Discussions You Might Find Interesting

1. UNIX for Dummies Questions & Answers

multiple disk in sun os

i have unix box , which currently has 2 scsi disk , as shown by format command, one at target 1 and another at target3 (which is current boot disk). can i use both the disk , if so will df -k show usage of both ? can any one guide me how to span file system across multiple disk. i m using sun 5.7... (4 Replies)
Discussion started by: raju
4 Replies

2. UNIX for Advanced & Expert Users

Help: Sun Disk partitioning for Sun V240 & StorEdge 3300

Dear Sun gurus, I have Sun Fire V240 server with its StorEdge 3300 disk-array. Following are its disks appeared in format command. I have prepared its partitions thru format and metainit & metattach (may be i have made wrong steps, causing the errors below because I have done thru some document... (1 Reply)
Discussion started by: shafeeq
1 Replies

3. Solaris

SUN T5240 vs M3000

Hi, We are planning to buy new server for our data center. Sun T5240 or M3000 which one have better performance, we are going to create many dt sessions in this server. So, i need your suggestions. RJS (4 Replies)
Discussion started by: rajasekg
4 Replies

4. Solaris

XSCF on M3000

Hi, I've updated a few M3000s to new firmware without any hassle, but on one of them the following is happening: XSCF> getflashimage -u wayner ftp://10.16.122.200/tftpboot/IKXCP1102.tar.gz Error: insufficient free space Any idea how to delete whatever old firmware is on there so I can... (7 Replies)
Discussion started by: cabaiste
7 Replies

5. SCO

sco 5.0.5 5.0.6 openscource replacment ?

is there a version of anything linux distro that could clone/emulate sco close enough to run the 1 software program we keep this server for ? boil this question down some if a program is running on a sco system now are there any alternatives ? (2 Replies)
Discussion started by: crosbymook
2 Replies

6. Solaris

Help with faulty Disk on Sun OS

Hi, Recently i came across a disk that seems to be faulty and need help. I have gathered some information by running below commands and any help on how to solve this will be great. # uname –a SunOS XYZ 5.7 Generic_106541-16 sun4u sparc SUNW,Ultra-4 #df -k Filesystem kbytes used... (3 Replies)
Discussion started by: phanidhar6039
3 Replies

7. Solaris

Application running too slow on Sun SPARC T5440 but run normal on sun M3000

Hi all, I have application running on sun server T5440 4x8x1.4 GHz, 64 GB RAM, application running very slow though load average too low. when I install my application on another server SUN M3000 (One CPU 1x8x2.5GHz, 8GB RAM), application run smoothly. Here is my server T5440 info: ... (6 Replies)
Discussion started by: insatiable1610
6 Replies

8. UNIX for Beginners Questions & Answers

Help with sed replacment

Hi All, I am new to Unix and have a simple question. I would like to do three sed replacements in a large text file. The command I am using is as follows.... sed –n –e ‘s/:A/:X/’ –e ‘s/:B/:Y/’ –e ‘s/:C/:Z/’ myfile.txt > myfile_SED.txt The : need to be the search to identify specific :A, :B,... (3 Replies)
Discussion started by: landrjos
3 Replies
cfgadm_scsi(1M) 					  System Administration Commands					   cfgadm_scsi(1M)

NAME
cfgadm_scsi - SCSI hardware specific commands for cfgadm SYNOPSIS
/usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option] -c function ap_id... /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_option] -x hardware_function ap_id... /usr/sbin/cfgadm [-v] [-a] [-s listing_option] [-o hardware_option] [-l [ap_id | ap_type ... ]] /usr/sbin/cfgadm [-v] [-o hardware_option] -t ap_id... /usr/sbin/cfgadm [-v] [-o hardware_option] -h [ap_id...] DESCRIPTION
The SCSI hardware specific library /usr/lib/cfgadm/scsi.so.1 provides the functionality for SCSI hot-plugging through the cfgadm(1M) com- mand. cfgadm operates on attachment points, which are locations in the system where hardware resources can be dynamically reconfigured. Refer to cfgadm(1M) for information regarding attachment points. For SCSI hot-plugging, each SCSI controller is represented by an attachment point in the device tree. In addition, each SCSI device is rep- resented by a dynamic attachment point. Attachment points are named through ap_ids. Two types of ap_ids are defined: logical and physical. The physical ap_id is based on the physical pathname, whereas the logical ap_id is a shorter more user-friendly name. For SCSI con- trollers, the logical ap_id is usually the corresponding disk controller number. For example, a typical logical ap_id would be c0. SCSI devices are named relative to the controller ap_id. Thus if a disk device is attached to controller c0, its ap_id can be: c0::dsk/c0t0d0 where dsk/c0t0d0 identifies the specific device. In general, the device identifier is derived from the corresponding logical link for the device in /dev. For example, a SCSI tape drive logical ap_id could be c0::rmt/0. Here c0 is the logical ap_id for the SCSI controller and rmt/0 is derived from the logical link for the tape drive in /dev/rmt. If an identifier can not be derived from the link in /dev, a unique identifier will be assigned to it. For example, if the tape device has no link in /dev, it can be assigned an ap_id of the form c0::st3 where st3 is a unique internally generated identifier. A simple listing of attachment points in the system will include attachment points at SCSI controllers but not SCSI devices. Use the -a flag to the list option (-l) to list SCSI devices as well. For example: # cfgadm -l Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown sysctrl0:slot0 cpu/mem connected configured ok sysctrl0:slot1 sbus-upa connected configured ok To list SCSI devices in addition to SCSI controllers: # cfgadm -al Ap_Id Type Receptacle Occupant Condition c0 scsi-bus connected configured unknown c0::dsk/c0t14d0 disk connected configured unknown c0::dsk/c0t11d0 disk connected configured unknown c0::dsk/c0t8d0 disk connected configured unknown c0::dsk/c0t0d0 disk connected configured unknown c0::rmt/0 tape connected configured unknown sysctrl0:slot0 cpu/mem connected configured ok sysctrl0:slot1 sbus-upa connected configured ok Refer to cfgadm(1M) for more information regarding listing attachment points. The receptacle and occupant state for attachment points at the SCSI controller have the following meanings: empty not applicable disconnected bus quiesced (I/O activity on bus is suspended) connected bus active configured one or more devices on the bus is configured unconfigured no device on the bus is configured The corresponding states for individual SCSI devices are: empty not applicable disconnected bus to which the device is attached is quiesced connected bus to which device is attached is active configured device is configured unconfigured device is not configured OPTIONS
cfgadm defines several types of operations besides listing (-l).These operations include testing, (-t), invoking configuration state changes, (-c), invoking hardware specific functions (-x), and obtaining configuration administration help messages (-h). -c function The following generic commands are defined for the SCSI hardware specific library: For SCSI controller attachment points, the following configuration state change operations are supported: connect Unquiesce the SCSI bus. disconnect Quiesce the bus (suspend I/O activity on bus). Incorrect use of this command can cause the system to hang. See NOTES. configure Configure new devices on SCSI bus. unconfigure Unconfigure all devices connected to bus. The following generic commands are defined for SCSI devices: configure configure a specific device unconfigure unconfigure a specific device -f When used with the disconnect command, forces a quiesce of the SCSI bus, if supported by hardware. Incorrect use of this command can cause the system to hang. See NOTES. -h ap_id SCSI specific help can be obtained by using the help option with any SCSI attachment point. -o hardware_option No hardware specific options are currently defined. -s listing_option Attachment points of class scsi can be listed by using the select sub-option. Refer to the cfgadm(1M) man page for additional information. -t ap_id No test commands are available at present. -x hardware_function Some of the following commands can only be used with SCSI controllers and some only with SCSI devices. In the following, controller_ap_id refers to an ap_id for a SCSI controller, for example, c0. device_ap_id refers to an ap_id for a SCSI device, for example: c0::dsk/c0dt3d0. The following hardware specific functions are defined: insert_device controller_ap_id Add a new device to the SCSI controller, controller_ap_id. This command is intended for interactive use only. remove_device device_ap_id Remove device device_ap_id. This command is intended for interactive use only. replace_device device_ap_id Remove device device_ap_id and replace it with another device of the same kind. This command is intended for interactive use only. reset_device device_ap_id Reset device_ap_id. reset_bus controller_ap_id Reset bus controller_ap_id without resetting any devices attached to the bus. reset_all controller_ap_id Reset bus controller_ap_id and all devices on the bus. EXAMPLES
Example 1: Configuring a Disk The following command configures a disk attached to controller c0: # cfgadm -c configure c0::dsk/c0t3d0 Example 2: Unconfiguring a Disk The following command unconfigures a disk attached to controller c0: # cfgadm -c unconfigure c0::dsk/c0t3d0 Example 3: Adding a New Device The following command adds a new device to controller c0: # cfgadm -x insert_device c0 The system responds with the following: Adding device to SCSI HBA: /devices/sbus@1f,0/SUNW,fas@e,8800000 This operation will suspend activity on SCSI bus c0 Continue (yes/no)? Enter: y The system responds with the following: SCSI bus quiesced successfully. It is now safe to proceed with hotplug operation. Enter y if operation is complete or n to abort (yes/no)? Enter: y Example 4: Replacing a Device The following command replaces a device attached to controller c0: # cfgadm -x replace_device c0::dsk/c0t3d0 The system responds with the following: Replacing SCSI device: /devices/sbus@1f,0/SUNW,fas@e,8800000/sd@3,0 This operation will suspend activity on SCSI bus: c0 Continue (yes/no)? Enter: y The system responds with the following: SCSI bus quiesced successfully. It is now safe to proceed with hotplug operation. Enter y if operation is complete or n to abort (yes/no)? Enter: y Example 5: Encountering a Mounted File System While Unconfiguring a Disk The following command illustrates encountering a mounted file system while unconfiguring a disk: # cfgadm -c unconfigure c1::dsk/c1t0d0 The system responds with the following: cfgadm: Component system is busy, try again: failed to offline: /devices/pci@1f,4000/scsi@3,1/sd@1,0 Resource Information ------------------ -------------------------- /dev/dsk/c1t0d0s0 mounted filesystem "/mnt" FILES
/usr/lib/cfgadm/scsi.so.1 hardware specific library for generic SCSI hot-plugging ATTRIBUTES
See attributes(5) for descriptions of the following attributes: +-----------------------------+-----------------------------+ | ATTRIBUTE TYPE | ATTRIBUTE VALUE | +-----------------------------+-----------------------------+ |Availability |SUNWcsl | +-----------------------------+-----------------------------+ SEE ALSO
cfgadm(1M), luxadm(1M), config_admin(3CFGADM), libcfgadm(3LIB), attributes(5) NOTES
The disconnect (quiesce) operation is not supported on controllers which control disks containing critical partitions such as root (/), /usr, swap, or /var. The disconnect operation should not be attempted on such controllers. Incorrect usage can result in a system hang and require a reboot. Hotplugging operations are not supported by all SCSI controllers. WARNINGS
The connectors on some SCSI devices do not conform to SCSI hotplug specifications. Performing hotplug operations on such devices can cause damage to the hardware on the SCSI bus. Refer to your hardware manual for additional information. SunOS 5.10 21 Sept 2005 cfgadm_scsi(1M)
All times are GMT -4. The time now is 10:20 PM.
Unix & Linux Forums Content Copyright 1993-2022. All Rights Reserved.
Privacy Policy