12-29-2011
Thanx jegaraman,
I am communicating the same thing to customer to bring the temp of the room below 22 degree. But they suspect to change the heat sink of the processor ? Is this a solution ?? I don't think so.
In that DC they are having some SF 280R servers also. But their concern is why the temp of the SF v440 server is increasing why not with 280 servers.
Is the amount of heat generated by a SF v440 server is same as SF280R server ?????
regards
Sudhansu
10 More Discussions You Might Find Interesting
1. Solaris
Got an curious issue.
I applied 109147-39 to, oh 15 or so various systems all running Jumpstarted Solaris 8. When I hit the first two V440s, they both failed with Return code 139. All non shell commands segfaulted from then on.
The patch modified mainly the linker libraries and commands.
... (2 Replies)
Discussion started by: BOFH
2 Replies
2. Solaris
Hello,
I hope you can help me. I am new to Sun servers and we have a Sun Fire v440 server in which one power supply failed, we are waiting for new one. But now our server is shutting down constantly. Is there any setting with which we can prevent this behaviour? (1 Reply)
Discussion started by: Tibor
1 Replies
3. Solaris
Dear All,
I am facing a specfic problem with my New SunFire T2000.Recently we bought new sunfire T2000 sparc server.When i am trying to install solaris 10 through cdrom , I get error messgae
Error:Last Trap: Instaruction Access Exception
{0} ok boot cdrom
Boot device:... (6 Replies)
Discussion started by: solaris8in
6 Replies
4. Solaris
First of all it's shut down 60 second after power on and write on console :
SC Alert: Correct SCC not replaced - shutting managed system down!
This is cured by moving out battery from ALOM card.
Now server start to loop during the testing.
That's on the console:
>@(#) Sun Fire V440,Netra... (14 Replies)
Discussion started by: Alisher
14 Replies
5. Solaris
Hello,
I am seeing error messages in V440 (OS = solaris 8). I have copied here :
The system does not reboot constantly and it is up for last 67 days. One more interesting thing I found, I see errors start appearing at 4:52AM last until 6am and again start at 16:52am on same day..
I... (5 Replies)
Discussion started by: upengan78
5 Replies
6. Solaris
Hi,
I was asked to connect a KVM screen to a Sun Fire V440 last night so I connected it up but no joy and nothing on the KVM screen. I was told that a reboot may fix the problem so connected to the ALOM and rebooted. On the plus side, the KVM screen now works but I lost the ALOM connection.
... (0 Replies)
Discussion started by: jimmy54321
0 Replies
7. Solaris
Hi:
I bougth an used Sun Fire v440, and It have a firmware password. When I turn on the server, it ask for firmware password. (I don 't know what is the correct password). I can access to SC, but when I want to access to OBP, Firmware Password appears again. I remove the battery for two hours,... (1 Reply)
Discussion started by: mguazzardo
1 Replies
8. Solaris
Hi,
I have Sun Fire V440. Boot disks are mirrored. system crashed and it's not coming up. Error message is
Insufficient metadevice database replicas located. Use Metadb to delete databases which are broken.
Boot disks are mirrored and other disks are ZFS configuration. Please... (2 Replies)
Discussion started by: samnyc
2 Replies
9. Solaris
Hi,
I have a SUN Fire V440 server running Solaris 8. One of the 4 disks do not appear when issued the format command. The "ready to remove" LED is not on either.
Metastat command warns that this disk "Needs maintenace". Can I just shutdown and power off the machine and then insert an... (5 Replies)
Discussion started by: Echo68
5 Replies
10. Solaris
Hi,
I have a Sun Fire V440 server that fails to boot up correctly. A lot of services are not started and the sytems acts really slow to commands. During boot I can see the following Error:
WARNING: /pci@1f,700000/scsi@2/sd@0,0 (sd1):
SCSI transport failed: reason 'reset': retrying... (15 Replies)
Discussion started by: oliwei
15 Replies
cvcd(1M) System Administration Commands cvcd(1M)
NAME
cvcd - virtual console daemon
SYNOPSIS
/platform/platform_name/cvcd
DESCRIPTION
The virtual console daemon, cvcd, is a server process that supports the network console provided on some platforms. The cvcd daemon accepts
network console connections from a remote host (only one host at any given time). Console input is read from this connection and forwarded
to cvc(7D) by way of cvcredir(7D).
Similarly, console output is read from cvcredir(7D) and forwarded across the network console connection. If cvcd dies, console traffic is
automatically rerouted through an internal hardware interface.
The cvcd daemon normally starts at system boot time. Each domain supports only one cvcd process at a time.
Caution: On Sun Enterprise 10000 domains, cvcd uses a configuration file (/etc/ssphostname) to determine the name of the host from
which network console connections are allowed. If the remote console host is renamed, you must edit the configuration file
to reflect that change.
OPERANDS
The following operands are supported:
platform_name The official Sun platform name used in packaging and code. For example, for Sun Fire 15K servers, the platform_name
would be SUNW,Sun-Fire-15000.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|Architecture |Sun Enterprise 10000 |
| |servers, Sun Fire High-End |
| |Systems |
+-----------------------------+-----------------------------+
|Availability |SUNWcvc.u |
+-----------------------------+-----------------------------+
SEE ALSO
svcs(1), svcadm(1M), services(4), attributes(5), smf(5), cvc(7D), cvcredir(7D)
Sun Enterprise 10000 SSP Reference Manual
System Management Services (SMS) Reference Manual
NOTES
The cvcd service is managed by the service management facility, smf(5), under the service identifier:
svc:/system/cvc
Administrative actions on this service, such as enabling, disabling, or requesting restart, can be performed using svcadm(1M). The ser-
vice's status can be queried using the svcs(1) command.
SunOS 5.10 11 Aug 2004 cvcd(1M)