Hello guys, I'm going crazy over here with a problem with a LUN created on a EMC CX3.
I did sucessfully managed to create the LUN on the Storage (the LUN is named DBLNX25EC_TST), after doing the following process:
I've managed to see the mentioned LUN as device emcpowerf
However, when I try to create a partition, here's the fdisk output:
What am I missing?
We currently have a Solaris box connected to a Clariion storage system that is utilising DMP for path failover. I would prefer to use EMC's Powerpath and was wondering if the two can coexist?
Basically, I am struggling to find any documentation on the subject and was wonder if anyone can give me... (2 Replies)
I have a list of LUN ID, my task is to find if disk has been added or not. How do I do that? I have been searching the forum and not able to find answer.
thanks (4 Replies)
Hi ,
I have a redhat 5.3 server which has 2 vg.. one is rootvg in local harddisk and another one is applicationvg in SAN.. When I reboot the server , EMC powerpath driver is not starting up automatically. Hence applicationvg is not mounting properly. Therefore I need to unmount it manually and... (4 Replies)
I have seen a few threads / posts on the forum's but nothing specific to what Iam after. So Iam hoping you can help.
Issue : Iam hoping to remove unused emc luns from my solaris servers , T2000 (5.10 Generic_142900-02). I have a list of the process I have followed for the removal of the luns.... (3 Replies)
Hello all,
i try to allocate the same LUN to two server (or more in the future)
i use solaris 10, vxvm (vxfs) for data and solaris zones and EMC DMX-4, i try to migrate solaris zones between servers in case of problem.
and this is what i want to do
- affect LUN to srv00124 and srv10155
-... (5 Replies)
It seems like I lost one path on my Solaris-11 box. But I want to make sure before going to Storage team, if issue is from OS side or Storage side. Storage team is able to see that only one wwwn is looged in their switch. I am not at server's physical location. What does below output says ? I... (0 Replies)
Hi,
We're trying out a SAN migration from HP EVA to EMC VMAX, and run into a bit of an issue with powerpath and zfs.
The method we're currently using to migrate is to export the HP EVA luns from our sun server, replicate using SAN based method, and then present the new luns to our Sun server... (7 Replies)
Hi Community,
I am facing one issue related storage accessing from solaris 10 machine(M5000). it was working fine then we shifted to another site. the only change on that site is FC switch.
The issue i am facing is from solaris machine i can able to see the LUN, it;s only a test lun of 30... (17 Replies)
Hi Experts , I want to start migrating our AIX 6.1 to AIX 7.1 . I am planning to use alt_disk_migration . Chris gibson has awesome documentation in the internet. However I am running into an issue with EMC odm filesets . So my current OS is AIX 6.1. and I have this :
lslpp -l | grep EMC
... (7 Replies)
we have an old AIX system with important data on an EMC LUN. the AIX server crashed and we had to rebuild it with the old AIX os 5.8. how do we reconnect the EMC LUN without losing the data? (15 Replies)
Discussion started by: jhudson12
15 Replies
LEARN ABOUT CENTOS
scsi-rescan
RESCAN-SCSI-BUS.SH(1) User Commands RESCAN-SCSI-BUS.SH(1)NAME
rescan-scsi-bus.sh - script for adding and removing SCSI devices without rebooting
SYNOPSIS
rescan-scsi-bus.sh [options] [host [host ...]]
OPTIONS -a, --alltargets
scan all targets, not just currently existing [default: disabled]
-d enable debug [default: 0]
-l activates scanning for LUNs 0--7 [default: 0]
-L NUM activates scanning for LUNs 0--NUM [default: 0]
-w, --wide
scan for target device IDs 0--15 [default: 0--7]
-c enables scanning of channels 0 1 [default: 0 / all detected ones]
-r, --remove
enables removing of devices [default: disabled]
-f, --flush
flush failed multipath devices [default: disabled]
-i, --issue-lip
issue a FibreChannel LIP reset [default: disabled]
-u, --update
look for existing disks that have been remapped
-s, --resize
look for resized disks and reload associated multipath devices, if applicable
--forcerescan
rescan existing devices
--forceremove
remove and readd every device (DANGEROUS)
--nooptscan
don't stop looking for LUNs is 0 is not found
--color
use coloured prefixes OLD/NEW/DEL
--hosts=LIST
scan only host(s) in LIST
--channels=LIST
scan only channel(s) in LIST
--ids=LIST
scan only target ID(s) in LIST
--luns=LIST
scan only lun(s) in LIST
--sync, --nosync
issue a sync / no sync [default: sync if remove]
--attachpq3
tell kernel to attach sg to LUN 0 that reports PQ=3
--reportlun2
tell kernel to try REPORT_LUN even on SCSI2 devices
--largelun
tell kernel to support LUNs > 7 even on SCSI2 devs
--sparselun
tell kernel to support sparse LUN numbering
Host numbers may thus be specified either directly on cmd line (deprecated) or or with the --hosts=LIST parameter (recommended).
LIST: A[-B][,C[-D]]... is a comma separated list of single values and ranges (No spaces allowed.)
SEE ALSO
rescan-scsi-bus.sh Homepage: http://www.garloff.de/kurt/linux/#rescan-scsi
sg3_utils Homepage: http://sg.danny.cz/sg
rescan-scsi-bus.sh 1.57 leden 2014 RESCAN-SCSI-BUS.SH(1)