12-14-2011
Why dont you using SVM? You can expand the FS with growfs. VXvm is the powerfull VM, but in case of local rootdisk, easy to use SVM. The best solution for Solaris root disk is SVM, except ZFS. IMHO
Last edited by rua; 12-14-2011 at 06:02 AM..
Reason: add
9 More Discussions You Might Find Interesting
1. Solaris
I don't understood why on SPARC-Platforms have not present RAID-Controller ? Sorry for my bad english, but it's crazy always setup software RAID !!! I whanna Hardware RAID and when i can find solution ? (7 Replies)
Discussion started by: jess_t03
7 Replies
2. Solaris
Hi,
I have t5120 sparc and I have 2 146 G drives in the system. I will be installing solaris 10 and also want the system mirrored using Hardware RAID "1"
The System did come preinstalled as it comes from sun. I did not do much on it.
I booted system using boot cdrom -s
gave format... (6 Replies)
Discussion started by: upengan78
6 Replies
3. Solaris
Hi,
I have a root with hardware RAID on c0t0d0 and c0t2d0. I would like to set the boot device sequence in OBP for both hdds.
I have checked in ls -l /dev/rdsk/ for the path of c0t2d0 but it does not exist. Can anyone shed some lights on this?
AVAILABLE DISK SELECTIONS:
0.... (12 Replies)
Discussion started by: honmin
12 Replies
4. UNIX for Dummies Questions & Answers
Hi
Can someone tell me what are the differences between software and hardware raid ?
thx for help. (2 Replies)
Discussion started by: presul
2 Replies
5. Solaris
Hi,
I have a question. Do LiveUpgrade supports hardware raid?
How to choose the configuration of the system disk for Solaris 10 SPARC?
1st Hardware RAID-1 and UFS
2nd Hardware RAID-1 and ZFS
3rd SVM - UFS and RAID1
4th Software RAID-1 and ZFS
I care about this in the future to take... (1 Reply)
Discussion started by: bieszczaders
1 Replies
6. Hardware
Hi all
I've just received my T3-1. It has 8 disks and I would like to configure RAID1 on the disks. The Sun documentation states that you can either use the OpenBoot PROMP utility called Fcode or you can use software via the Solaris OS.
The documentation doesn't make it clear if:
1. The... (6 Replies)
Discussion started by: soliberus
6 Replies
7. Solaris
We have hardware RAID configured on our T6320 server and two LDOMs are running on this server. One of our disk got failed and replaced. After replacemnt the newly installed disk not detected by RAID controlled so Oracle suggested to upgrade the REM firmware. As this is the standalone production... (0 Replies)
Discussion started by: rock123
0 Replies
8. Solaris
Dear All ,
we have hardware raid 1 implemented on Solaris Disks.
We need to patch the Servers. Kindly let me know how to patch hardware raid implemented Servers.
Thanks...
Rj (7 Replies)
Discussion started by: jegaraman
7 Replies
9. Solaris
Dear All ,
Pl find the below command ,
# raidctl -l
Controller: 1
Volume:c1t0d0
Disk: 0.0.0
Disk: 0.1.0
Disk: 0.3.0
#
raidctl -l c1t0d0
Volume Size Stripe Status Cache RAID
Sub Size ... (10 Replies)
Discussion started by: jegaraman
10 Replies
LEARN ABOUT HPUX
vxr5check
vxr5check(1M) vxr5check(1M)
NAME
vxr5check - verify RAID-5 volume parity
SYNOPSIS
/etc/vx/bin/vxr5check [-i | -v] [-g diskgroup] volume
DESCRIPTION
The vxr5check utility compares the parity of each stripe of a RAID-5 volume specified by volume. vxr5check reads the data for each stripe,
generates the parity for this stripe, and compares this parity with the existing parity.
vxr5check can be run against the entire RAID-5 volume, or incrementally on RAID-5 stripe boundaries, by specifying the -i option.
OPTIONS
-g diskgroup
Specifies the Veritas Volume Manager (VxVM) disk group name for the RAID-5 volume name for verification. If this option is not
specified, the default disk group is determined using the rules given in the vxdg(1M) manual page.
-i Verifies the RAID-5 volume incrementally per stripes. If a parity mismatch is found, that stripe location is displayed.
-v Verbose output for the incremental vxr5check verification. The verbose option outputs each stripe number that is being verified.
OUTPUT FORMAT
In verbose mode and incremental mode, summary reports for each stripe of the RAID-5 volume are printed in output records. If an error is
returned for a stripe, then an error message and stripe number are displayed. In non-verbose mode, if an error is returned, an error mes-
sage is displayed.
If a parity mismatch error is determined on a stripe, vxr5check exits on that stripe and does not continue for the remaining stripes in the
RAID-5 volume.
FILES
/usr/lib/vxvm/bin/vxr5vrfy The utility that vxr5check calls to perform RAID-5 parity verification operations for the specified RAID-5
volume.
EXIT CODES
The vxr5check utility exits with a non-zero status if the attempted operation fails. A non-zero exit code is not a complete indicator of
the problems encountered, but rather denotes the first condition that prevented further execution of the utility.
See vxintro(1M) for a list of standard exit codes.
NOTES
Do not run vxr5check on a volume that is in degraded mode.
SEE ALSO
vxevac(1M), vxintro(1M), vxmend(1M), vxvol(1M)