It is very simple - it means 'using the fibre channel protocol over an internet connection instead of over fiber channel', like iSCSI uses internet instead of a direct SCSI connection.
If your boss wants this to save money, be careful. We have both. There are some serious issues with OS drivers e.g. solaris scsi_vhci
9 More Discussions You Might Find Interesting
1. Solaris
I Have IBM ESS 800, trying to configure SAN storage using Fiber card. I installed the SDD driver & can see the disks however, when I did
# datapath query device
I have the disks shown in slices
# ./datapath query device
Total Devices : 8
Dev#: 0 Device Name: vpath1a Type:... (0 Replies)
Discussion started by: Remi
0 Replies
2. AIX
Hi,
I have a strange problem. we're trying to connect an IBM pseries, to a Brocade switch, for SAN acess, using a badged emulex card, (IBM FC6239) WE can configure the device to see the fabric. The only problem we have is that the Brocade sees the HBA as storage, and not as a HBA.
We've zoned... (1 Reply)
Discussion started by: praxis22
1 Replies
3. Solaris
Hi,
How can we differentiate a SAN disk with a Solaris local disk?
Please respond.
Thanks (4 Replies)
Discussion started by: balu_solaris
4 Replies
4. UNIX for Advanced & Expert Users
Hi,
I have 4 servers that I connected SUN HBAs on. (SAN is IBM - ESS 800 with Brocade switch)
I installed the SAN foundation kit, IBMsdd drivers, Solaris Patch 108974-50 & SANsurfer CLI.
(I'm running Solaris 8 - HBA is SG-XPC11FC-QL2
On 1 of the 4 servers show the HBAs as CONNECTED, but... (3 Replies)
Discussion started by: Remi
3 Replies
5. Solaris
Hi
I would like to remove SAN luns from system and do not want them even after system reboot,
format
Searching for disks...done
df -kh
I know last 4 partitions are from SAN but there could be more.
Can someone please help me correct steps to remove SAN Luns.
vxdisk list
... (2 Replies)
Discussion started by: upengan78
2 Replies
6. Solaris
Hi,
I have configured our SAN Storage to be connected to our new SUN T5220.
On the SAn it looks all fine
on the server I do not see any connection:
cfgadm -al
Ap_Id Type Receptacle Occupant Condition
c1 scsi-bus connected ... (4 Replies)
Discussion started by: manni2
4 Replies
7. Solaris
My current situation is like this, I have a v440 connected to a netapp central storage 3140 via fiber channel, my OS and oracle is installed in the internal drive of the v440.
What I would like to do is to advertise another LUN in netapp to the v440 and let my v440 boot from it so I can start... (3 Replies)
Discussion started by: q8devilish
3 Replies
8. Solaris
I have a solaris 10 box which does not have internal disks it has just a single dual port HBA card. Storage team has assigned 2 LUNs to the system and i can see it from the probe-scsi-all
/pci@3,700000/SUNW,emlxs@0,1
Device PortID 10100 WWPN 5006016941e0a08d
LUN 0 Disk DGC ... (0 Replies)
Discussion started by: fugitive
0 Replies
9. Solaris
Hi All,
Hopefully you can answer my question.
We are about to move to a new Fibre Channel infrastructure going from Cisco to Brocade switches. Amongst others, we have a number of Solaris 9 hosts which connect to our EVA5000 and EVA8100 array's.
What is involved in moving the Solaris hosts to... (3 Replies)
Discussion started by: eptc
3 Replies
fp(7d) Devices fp(7d)
NAME
fp - Sun Fibre Channel port driver
DESCRIPTION
The fp driver is a Sun fibre channel nexus driver that enables fibre channel topology discovery, device discovery, fibre channel adapter
port management and other capabilities through well-defined fibre channel adapter driver interfaces.
The fp driver requires the presence of a fabric name server in fabric and public loop topologies to discover fibre channel devices. In pri-
vate loop topologies, the driver discovers devices by performing PLOGI to all valid AL_PAs, provided that devices do not participate in
LIRP and LILP stages of loop initialization.
CONFIGURATION
The fp driver is configured by defining properties in the fp.conf file. The fp driver supports the following properties:
mpxio-disable
Solaris I/O multipathing is enabled or disabled on fibre channel devices with the mpxio-disable property. Specifying mpxio-disable="no"
activates I/O multipathing, while mpxio-disable="yes" disables the feature.
Solaris I/O multipathing may be enabled or disabled on a per port basis. Per port settings override the global setting for the specified
ports. The following example shows how to disable multipathing on port 0 whose parent is /pci@8,600000/SUNW,qlc@4:
name="fp" parent="/pci@8,600000/SUNW,qlc@4" port=0
mpxio-disable="yes";
manual_configuration_only
Automatic configuration of SCSI devices in the fabric is enabled by default and thus allows all devices discovered in the SAN zone to be
enumerated in the kernel's device tree automatically. The manual_configuration_only property may be configured to disable the default
behavior and force the manual configuration of the devices in the SAN. Specifying manual_configuration_only=1 disables the automatic con-
figuration of devices.
FILES
/kernel/drv/fp
32-bit ELF kernel driver (x86)
/kernel/drv/amd64/fp
64-bit ELF kernel driver (x86)
/kernel/drv/sparcv9/fp
64-bit ELF kernel driver (SPARC)
/kernel/drv/fp.conf
fp driver configuration file.
ATTRIBUTES
See attributes(5) for descriptions of the following attributes:
+-----------------------------+-----------------------------+
| ATTRIBUTE TYPE | ATTRIBUTE VALUE |
+-----------------------------+-----------------------------+
|mpxio-disable |Unstable |
+-----------------------------+-----------------------------+
|manual_configuration_only |Obsolete |
+-----------------------------+-----------------------------+
|Availability |SUNWfctl |
+-----------------------------+-----------------------------+
SEE ALSO
cfgadm_fp(1M), prtconf(1M), stmsboot(1M), driver.conf(4), attributes(5), fcp(7D), fctl(7D), scsi_vhci(7D)
Writing Device Drivers
Fibre Channel Physical and Signaling Interface (FC-PH) ANSI X3.230: 1994
Fibre Channel Generic Services (FC-GS-2) Project 1134-D
Fibre Channel Arbitrated Loop (FC-AL) ANSI X3.272-1996
Fibre Channel Protocol for SCSI (FCP) ANSI X3.269-1996
SCSI-3 Architecture Model (SAM) Fibre Channel Private Loop SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) ANSI X3.270-1996
SCSI Direct Attach (FC-PLDA) NCITS TR-19:1998
Fabric Loop Attachment (FC-FLA), NCITS TR-20:1998
SunOS 5.10 2 Dec 2004 fp(7d)